Assessment of Image Quality Parameters for Computed Tomography in the City of Yaoundé

DOI: 10.4236/ojrad.2018.81005, PP. 37-44

Keywords: CT, Image Quality, Catphan 700

Full-Text   Cite this paper   Add to My Lib

Abstract:

Performance evaluation of computed tomography is not significant in the Republic of Cameroon in general and more particularly in the city of Yaoundé. Therefore, this work aimed to analyze image performances of 05 CT scanners in 05 medical facilities in the city of Yaoundé, by using the Catphan 700 phantom and test procedures of the Atomic Energy Agency. Five quality control tests were performed on each CT-Scanner. All the CT scanners evaluated showed good results and were not disapproved in three of the five tests performed. The difference between the measured spatial resolution for each of the five CT scanners and the spatial resolution specified by the manufacturer was very high. The low contrast resolution of four of the five CT scanners was found low when compared to the low contrast resolution specified by the manufacturers.

References

[1]  International Atomic Energy Agency, Quality Assurance Program for Computed Tomography; Diagnostic and Therapy Applications, IAEA Human Health Series N° 11, IAEA, Vienna (2012).
[2]  Birnbaum, B.A., Hindman, N., Lee, J. and Babb, J.S. (2007) Multi-Detector Row CT Attenuation Measurements: Assessment of Intra- and Interscanner Variability with an Anthropomorphic Body CT Phantom. Radiology, 242, 109-119.
https://doi.org/10.1148/radiol.2421052066
[3]  IEC 61223-3-5. International Standard IEC 61223-3-5. Evaluation and Routine Testing in Medical Imaging Departments—Part 3-5: Acceptance Tests—Imaging Performance of Computed Tomography X-Ray Equipment; 2013.
[4]  IEC 61223-2-6. International Standard IEC 61223-2-6. Evaluation and Routine Testing in Medical Imaging Departments—Part 2-6: Acceptance Tests—Imaging Performance of Computed Tomography X-Ray Equipment; 2006.
[5]  IPEM (2005) Report 91.
[6]  The Phantom Laboratory, United States: Catphan® 700 Manual. ©2013.
http://www.phantomlab.com/catphan-phantoms/
[7]  Garayoa, J. and Castro, P. (2013) A Study on Image Quality Provided by a Kilovoltage Cone-Beam Computed Tomography. Journal of Applied Clinical Medical Physics, 14, 3888.
https://doi.org/10.1120/jacmp.v14i1.3888
[8]  Manson, E.N., et al. (2016) Assessment of Some Image Quality Tests on a 128 Slice Computed Tomography Scanner Using a Catphan700 Phantom. Journal of Medical Physics, 41, 153-156.
https://doi.org/10.4103/0971-6203.181637
[9]  Gulliksrud, K., Stokkea, C. and Martinsen, A.C.T. (2014) How to Measure CT Image Quality: Variations in CT-Numbers, Uniformity and Low Contrast Resolution for a CT Quality Assurance Phantom. Physica Medica.
[10]  Elnour, H., Hassan, H.A., Mustafa, A., Osman, H., Alamri, S. and Yasen, A. (2017) Assessment of Image Quality Parameters for Computed Tomography in Sudan. Open Journal of Radiology, 7, 75-84.
https://doi.org/10.4236/ojrad.2017.71009
[11]  American College of Radiology, ACR-SCBT-MR-SPR Practice Parameter for the Performance of Computed Tomography (CT) of Computed Tomography (CT) of the Pelvis. 2016.
https://www.acr.org/-/media/ACR/Files/Practice-Parameters/ct-abd-pel.pdf

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133