Influence of Temperature on the Measuring Accuracy of Devices Based on Surface Plasmon Resonance Phenomenon

DOI: 10.4236/mi.2018.71001, PP. 1-10

Keywords: Surface Plasmon Resonance, Temperature Factor, Measuring Accuracy

Full-Text   Cite this paper   Add to My Lib

Abstract:

The main reasons for the occurrence of temperature error and perspective directions of decreasing of its value are presented by improving the device design based on the phenomenon of surface plasmon resonance (SPR) and numerical methods of processing the results of measurements by this device. The most essential influence on changes in results of measurements can be rendered by temperature changes in the analyte refractive index. It is shown that the application of the integrated temperature stabilization of the device with the test substance, and numerical processing of the measurement results for compensation of temperature changes of the test substance and the use of film heaters it is possible to reduce the measurement error of the refractive index of the analyte at least 30 times from 2.4 × 10-4 to 7.6 × 10-6.

References

[1]  Liedberg, B., Nylander, C. and Lundstrom, I. (1983) Surface Plasmon Resonance for Gas Detection and Biosensing. Sensors and Actuators B: Chemical, 4, 299-304.
https://doi.org/10.1016/0250-6874(83)85036-7
[2]  Samoylov, A.V., Mirsky, V.M., Hao, Q., Swart, C., Shirshov, Y.M. and Wolfbeis, O.S. (2005) Nanometer-Thick SPR Sensor for Gaseous HCl. Sensors and Actuators B: Chemical, 106, 369-372.
https://doi.org/10.1016/j.snb.2004.08.029
[3]  Dorozinsky, G., Lobanov, M. and Maslov, V. (2015) Detection of Methanol Vapor by Surface Plasmon Resonance Method. Eastern-European Journal of Enterprise Technologies, 4, 4-7.
https://doi.org/10.15587/1729-4061.2015.47079
[4]  Matsubara, K., Kawata, S. and Minami, S. (1988) Optical Chemical Sensor Based on Surface Plasmon Measurement. Applied Optics, 27, 1160-1163.
https://doi.org/10.1364/AO.27.001160
[5]  Gridina, N., Dorozinsky, G., Khristosenko, R., Maslov, V., Samoylov, A., Ushenin, Yu. and Shirshov, Yu. (2013) Surface Plasmon Resonance Biosensor. Sensors & Transducers Journal, 149, 60-68.
[6]  Xu, H. and Kall, M. (2003) Modeling the Optical Response of Nanoparticle-Based Surface Plasmon Resonance Sensors. Sensors and Actuators, 87, 244-249.
https://doi.org/10.1016/S0925-4005(02)00243-5
[7]  Rella, R., Siciliano, P., Quaranta, F., Primo, T., Valli, L., et al. (2000) Gas Sensing Measurements and Analysis of the Optical Properties of Poly [3-(butylthio)thiophene] Langmuir-Blodgett Films. Sensors and Actuators B: Chemical, 68, 203-209.
https://doi.org/10.1016/S0925-4005(00)00430-5
[8]  Dorozinsky, G., Liptuga, A., Gordienko, V., Maslov, V. and Pidgornyi, V. (2015) Diagnostics of Motor Oil Quality by Using the Device Based on Surface Plasmon Resonance Phenomenon. Scholars Journal of Engineering and Technology, 3, 372-374.
[9]  Minunni, M. and Mascini, M. (1993) Detection of Pesticide in Drinking Water Using Real-Time Biospecific Interaction Analysis. Analytical Letters, 26, 1441-1460.
https://doi.org/10.1080/00032719308017424
[10]  Dharmalingam, G., Joy, N.A., Grisafe, B. and Carpenter, M.A. (2012) Plasmonics-Based Detection of H2 and CO: Discrimination between Reducing Gases Facilitated by Material Control. Beilstein Journal of Nanotechnology, 3, 712-721.
https://doi.org/10.3762/bjnano.3.81
[11]  Yanase, Y., Hiragun, T., Ishii, K., Kawaguchi, T., et al. (2014) Surface Plasmon Resonance for Cell-Based Clinical Diagnosis. Sensors, 14, 4948-4959.
https://doi.org/10.3390/s140304948
[12]  Homola, J. (2006) Surface Plasmon Resonance Based Sensors. In: Wolfbeis, O.S., Ed., Springer Series on Chemical Sensors and Biosensors, Springer-Verlag, Berlin, 45-67.
https://doi.org/10.1007/5346_014
[13]  Dorozinsky, G.V., Maslov, V.P. and Ushenin, Yu.V. (2016) Sensor Devices Based on Surface Plasmon Resonance. Monograph, Kyiv National Technical University of Ukraine “KPI”, Publishing House “Politeknika”, Kyiv, 264.
[14]  Dorozinsky, G., Doroshenko, T. and Maslov, V. (2015) Influence of Technological Factors on Sensitivity of Analytical Devices Based on Surface Plasmon Resonance. Journal of Sensor Technology, 5, 54-61.
https://doi.org/10.4236/jst.2015.52006
[15]  Moreira, C.S., Neff, H., Lima, A. and Thirstrup, G. (2008) Temperature-Dependent Sensitivity of Surface Plasmon Resonance Sensors at the Gold-Water Interface. Sensors and Actuators B Chemical, 134, 854-862.
https://doi.org/10.1016/j.snb.2008.06.045
[16]  Chiang, H.P., Chen, Ch.-M., Yeh, H.T. and Leung, P.T. (2004) Surface Plasmon Resonance Monitoring of Temperature via Phase Measurement. Optics Communications, 241, 409-418.
https://doi.org/10.1016/j.optcom.2004.07.045
[17]  Özdemir, S.K. and Turhan-Sayan, G. (2003) Temperature Effects on Surface Plasmon Resonance: Design Considerations for an Optical Temperature Sensor. Journal of Light Wave Technology, 21, 805-815.
https://doi.org/10.1109/JLT.2003.809552
[18]  Dorozinsky, G.V. (2016) Analysis of the Main Errors of Measurement of the Refractive Index of the Analyte by Device “Plasmon-6”. East European Scientific Journal, 5, 54-61.
[19]  Bayborodyn, Yu.V. (1988) Fundamentals of Laser Technics. 2nd Edition, Vyshcha Shkola, Kyiv, 383.
[20]  Hlaholyev, S.P. (1934) Quartz Glass. Property, Production, Appliance, GHTI, Moscow, 214.
[21]  Ravdel, A.A. and Ponomarova, A.M. (1998) Short Guide Physico-Chemical Values. 8th Edition, Special Literature, St. Petersburg, 232.
[22]  Dorozinsky, G., Dunaevsky, V. and Maslov, V. (2013) Thermal-Vision Method of Investigations and Control of Device Based on Surface Plasmon Resonance. Universal Journal of Control and Automation, 2, 34-39.
[23]  Dorozinsky, G., Maslov, V., Samoylov, A. and Ushenin, Yu. (2013) Reducing Measurement Uncertainty of Instruments Based on the Phenomenon of Surface Plasmon Resonance. American Journal of Optics and Photonics, 1, 17-22.
https://doi.org/10.11648/j.ajop.20130103.12
[24]  Ushenin, Yu.V., Maslov, V.P., Dorozinsky, G.V., Turu, T.A. and Kachur, N.V. (2016) Application of Temperature Sensors for Improving the Device Based on the Phenomenon of Surface Plasmon. Sensor Electronics and Мicrosystem Technologies, 13, 33-40.
https://doi.org/10.18524/1815-7459.2016.1.70293
[25]  Maslov, V.P., Kachur, N.V. and Dorozinsky, G.V. (2016) Investigation of Sensors Based on ITO Nanofilms in SPR-Devices. American Journal of Optics and Photonics, 4, 20-24.
https://doi.org/10.11648/j.ajop.20160403.11

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133