全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Endoscopic Management of Migrated Intra Uterine Device in Sub-Saharan Health Setting Area. Our Experience about Seventeen Cases

DOI: 10.4236/ss.2018.91003, PP. 17-23

Keywords: IUD Migration, Bladder, Pain, Endoscopy Surgery, Mali

Full-Text   Cite this paper   Add to My Lib

Abstract:

Intra uterine device migration is a relatively rare event. The migration of the IUD in the surrounded viscera can be managed by endoscopy approach. Objectives: We reported our experience to determine the epidemiologic characteristics of patients that presented migrated IUD, to report clinical aspects and describe the laparoscopic management. Method: We conducted a descriptive and prospective survey from January 1st, 2014 to October 31, 2016. That survey took place in the department of gynecology and obstetrics of Point G Teaching hospital, Bamako, Mali. Population study concerned patients with intra uterine device complications. Statistic tests used have been X2 or Fisher test according their application conditions. P < 0.05 was considered statistically significant. Results: Seventeen patients were included. Mean age of patients is 29 years with extremes of 13 years and 44 years. The main reference incitement of patients were perforation of the uterus and pelvis pain (27.8% for each), misplaced IUD (22.3%). Complications observed were intra uterine device migrated in to the bladder (1 case), in the abdomen (10 cases), in the ovary (2 cases) and in the uterine tuba (1 case). Three perforations were done without migration in to surrounded viscera. We used endoscopic surgery among all of them. But in one case we switched endoscopy method in to laparotomy because of important intra peritoneal bleeding to end the management of the patient. No death occurred and mean duration of the stay of hospitalization was 2 days. Conclusion: IUD migration is a scarce event. All the surrounded viscera can be the site of its migration. The management of that complication is usually done by endoscopy method.

References

[1]  Atabekoglu, C., Yalçin, I., Taskin, S., Kahraman, K. and Sönmezer, M. (2012) Endoscopic Management of Migrated Intrauterine Device to the Bladder. International Medecine and Applied Science, 1, 48-49.
https://doi.org/10.1556/IMAS.4.2012.1.8
[2]  Mseddi, A.M., Ben Mefteh, I., Hadj Slimane, M., Hamza, M., Fourati, H., Derbel, M., Rebai, N., Gassara, H., Bouassida, M., Chaabène, K. and Mhiri, M.N. (2017) Intra Uterine Device Migrated into the Bladder. J.I.M. Sfax, 26, 58-61.
[3]  Kallat, A., Ibrahimi, A., Fahsi, O., El Sayegh, H., Iken, A., Benslimane, L. and Nouini, Y. (2017) Intra Uterine Device : About a Rare Complication and Literature Review. The Pan African Medical Journal, 27, 1-3.
[4]  Lachiri, B., Hafidi, M.R., Zazi, A., Fagouri, H., Kouach, J. and Rahali, D.M. (2014) Migratory IUD: Report of Two Cases and Review of the Literature. The Pan African Medical Journal, 19, 361-364.
[5]  Tepper, N.K., Curtis, K.M., Nanda, K. and Jamieson, J.D. (2016) Safety of Intrauterine Devices among Women with HIV: A Systematic Review. Contraception, 6, 713-724.
https://doi.org/10.1016/j.contraception.2016.06.011
[6]  Dahiya, K., Duhan, N., Nanda, S. and Lakra, P. (2010) Misplaced Intrauterine Device (IUD): The Endoscopic Management. JSAFOG, 2, 137-139.
https://doi.org/10.5005/jp-journals-10006-1082
[7]  Sano, M., Nemoto, K., Miura, T. and Suzuki, Y. (2017) Endoscopic Treatment of Intrauterine Device Migration into the Bladder with Stone Formation. Journal of Endourology, 3, 105-107.
https://doi.org/10.1089/cren.2017.0038
[8]  Sawant, A., Kasat, G.V., Kumar, V., Pawar, P., Tamhankar, A. and Kapadnis, L. (2015) Endoscopic Removal of Intrauterine Contraceptive Device Embedded into Detrusor Muscle of Urinary Bladder: Our Experience of Two Cases. International Journal of Reproduction, Contraception, Obstetrics and Gynecology, 6, 2096-2099.
https://doi.org/10.18203/2320-1770.ijrcog20151328
[9]  Bhowate, P., Bhargava, A. and Jaiswa, A. (2016) Laparoscopic Management of Perforated Copper “T” in Sigmoid Colon—Two Stage Approach. International Journal of Surgical International Journal of Surgery Cases, 2, 6-7.
[10]  Kassab, B. and Audra, P. (1999) The Migrating Intrauterine Devices. Case Report and Review of Literature. Contraception, Fertilite, Sexualite, 27, 696-700.
[11]  Gunbey, H.P., Sayit, A.T., Idilman, I.S. and Aksoy, O. (2014) Migration of Intrauterine Devices with Radiological Findings: Report on Two Case. BMJ Case Reports, 10, 1-3.
[12]  Shariaghdas, F., Mohammad, A. and Abidi, H. (2007) Laparoscopic Removal of a Migrated Intrauterine Device. Urology Journal, 4, 177-179.
[13]  Ozgun, M.T., Batukan, C., Serin, I.S., Ozcelik, B., Basbug, M. and Dolanbay, M. (2007) Surgical Management of Intra-Abdominal Mislocated Intrauterine Devices. Contraception, 75, 96-100.
https://doi.org/10.1016/j.contraception.2006.09.011
[14]  Bierman, A., Lefel, O., Segev, Y. and Lavie, O. (2010) Laparoscopic Removal of an Intrauterine Device Following Colon Perforation. JSLS, 14, 456-458.
https://doi.org/10.4293/108680810X12924466006963
[15]  Kaislasuo, J., Suhonen, S., Gissler, L., Lahteenmaki, P. and Heikinheimo, O. (2013) Uterus Perforation Caused by Intrauterine Devices: Clinical Course and Treatment. (2013) Human Reproduction, 28, 1546-1551.
https://doi.org/10.1093/humrep/det074
[16]  Heinberg, E.M., McCoy, T.W. and Pasic, R. (2008) The Perforated Intrauterine Device: Endoscopic Retrieval. JSLS, 12, 97-100.
[17]  Mustafa, M. (2009) Erosion of an Intrauterine Contraceptive Device through the Bladder Wall Causing Calculus: Management and Review of the Literature. Urologia Internationalis, 3, 370-371.
https://doi.org/10.1159/000209376
[18]  Istanbulluoglu, M.O., et al. (2008) Bladder Perforation Related to Intrauterine Device. Journal of the Chinese Medical Association, 6, 207-209.
https://doi.org/10.1016/S1726-4901(08)70105-9

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133