Development of an Artificial Finger-Like Knee Loading Device to Promote Bone Health

DOI: 10.4236/jbise.2017.1011041, PP. 550-561

Keywords: Osteoblasts, Mechanical Loading, Artificial Hand, Bone Growth

Full-Text   Cite this paper   Add to My Lib

Abstract:

This study presents the development of an innovative artificial finger-like device that provides position specific mechanical loads at the end of the long bone and induces mechanotransduction in bone. Bone cells such as osteoblasts are the mechanosensitive cells that regulate bone remodelling. When they receive gentle, periodic mechanical loads, new bone formation is promoted. The proposed device is an under-actuated multi-fingered artificial hand with 4 fingers, each having two phalanges. These fingers are connected by mechanical linkages and operated by a worm gearing mechanism. With the help of 3D printing technology, a prototype device was built mostly using plastic materials. The experimental validation results show that the device is capable of generating necessary forces at the desired frequencies, which are suitable for the stimulation of bone cells and the promotion of bone formation. It is recommended that the device be tested in a clinical study for confirming its safety and efficacy with patients.

References

[1]  Lanyon, L.E., et al. (1975) Bone Deformation Recorded in Vivo from Strain Gauges Attached to the Human Tibial Shaft. Acta Orthopaedica Scandinavica, 46, 256-268.
https://doi.org/10.3109/17453677508989216
[2]  Ozcivici, E., Luu, Y.K., Rubin, C.T. and Judex, S. (2010) Low-Level Vibrations Retain Bone Marrow’s Osteogenic Potential and Augment Recovery of Trabecular Bone during Reambulation. PLoS One, 5, e11178.
https://doi.org/10.1371/journal.pone.0011178
[3]  Takano-Yamamoto, T. (2014) Osteocyte Function under Compressive Mechanical Force. Japanese Dental Science Review, 50, 29-39.
https://doi.org/10.1016/j.jdsr.2013.10.004
[4]  Albrektsson, T. and Johansson, C. (2001) Osteoinduction, Osteoconduction and Osseointegration. European Spine Journal, 10, S96-S101.
[5]  Lee, C., Grad, S., Wimmer, M. and Alini, M. (2005) The Influence of Mechanical Stimuli on Articular Cartilage Tissue Engineering. Topics in Tissue Engineering, 2, 1-32.
[6]  Health Quality Ontario (2004) Pyrocarbon Finger Joint Implant: An Evidence-Based Analysis. Ontario Health Technology Assessment Series, 4, 1-31. (Print).
[7]  Bioventus. Ultrasound Bone Healing System.
http://www.exogen.com/us/about-exogen
[8]  Orthofix Inc. (2010) Physio-Stim.
http://web.orthofix.com/Products/Pages/Physio-Stim.aspx?catid=28
[9]  Anthem Inc. (2014) Electrical Bone Growth Stimulation. DME. 00004., 08/14/2014, Anthem Medicalpolicy.
https://www.anthem.com/medicalpolicies/policies/mp_pw_a050280.htm
[10]  Anthem Inc. (2014) Ultrasound Bone Growth Stimulation. DME. 00004, 08/14/2014, Anthem Medical Policy.
https://www.anthem.com/medicalpolicies/policies/mp_pw_a050287.htm
[11]  Zhang, P., Malacinski, G.M. and Yokota, H. (2008) Joint Loading Modality: It’s Application to Bone Formation and Fracture Healing. British Journal of Sports Medicine, 42, 556-560.
https://doi.org/10.1136/bjsm.2007.042556
[12]  Kwon, R.Y., Meays, D.R., Tang, W.J. and Frangos, J.A. (2010) Microfluidic Enhancement of Intramedullary Pressure Increases Interstitial Fluid Flow and Inhibits Bone Loss in Hindlimb Suspended Mice. Journal of Bone and Mineral Research, 25, 1798-1807.
https://doi.org/10.1002/jbmr.74
[13]  Zhang, P., Su, M., Liu, Y., Hsu, A. and Yokota, H. (2007) Knee Loading Dynamically Alters Intramedullary Pressure in Mouse Femora. Bone, 40, 538-543.
https://doi.org/10.1016/j.bone.2006.09.018
[14]  Zhang, P., Turner, C.H. and Yokota, H. (2009) Joint Load-ing-Driven Bone Formation and Signaling Pathways Predicted from Genome-Wide Expression Profiles. Bone, 44, 989-998.
https://doi.org/10.1016/j.bone.2009.01.367
[15]  Zhang, P. and Yokota, H. (2011) Knee Loading Stimulates Healing of Mouse Bone Wounds in a Femur Neck. Bone, 49, 867-872.
https://doi.org/10.1016/j.bone.2011.06.020
[16]  Fitzwater, D., Dodge, T., Chien, S., Yokota, H. and Anwar, S. (2013) Development of a Portable Knee Rehabilitation Device That Uses Mechanical Loading. Journal of Medical Devices, 7, Article ID: 041007.
https://doi.org/10.1115/1.4024830
[17]  Korupolu, S., Anwar, S., Yokota, H. and Chien, S. (2015) Development of an under Actuated Robotic Device for Knee Loading Applications. ASME International Mechanical Engineering Congress and Exposition, Houston, 13-19.
https://doi.org/10.1115/IMECE2015-51017
[18]  Robotic (2016) Robotic Hand.
http://robotiq.com/products/industrial-robot-hand
[19]  Shadow Robot Company (2016) Shadow Dexterous Hand.
https://www.shadowrobot.com/products/dexterous-hand
[20]  Halabi, O. and Kawasaki, H. (2010) Five Fingers Haptic Interface Robot HIRO: Design, Rendering, and Applications. In: Zadeh, M.H., Ed., Advances in Hap-tics, InTech.
https://doi.org/10.5772/8691
http://www.intechopen.com/books/advances-in-haptics/five-fingers-haptic-interface-robot-hiro-design-rendering-and-applications
[21]  Sandia Corporation (2016) Sandia Hand.
http://www.sandia.gov/research/robotics/advanced_manipulation/Sandia_Hand.html
[22]  Korupolu, S., Anwar, S., Yokota, H. and Chien, S. (2016) Finite Element Analysis of an under Actuated Robotic Device for Knee Loading Applications. ASME International Mechanical Engineering Congress and Exposition.
https://doi.org/10.1115/IMECE2016-65271
[23]  ANSYS Inc. Engineering Data. Release 15.0.
http://www1.ansys.com/customer/content/documentation/120/wb_eda.pdf
[24]  Stratasys ABS M30.
http://usglobalimages.stratasys.com/Main/Files/Material_Spec_Sheets/MSS_FDM_ABSM30.pdf

Full-Text