The paper reports some technical solutions, which suggested or used for increasing of environmental protection during accidents at NPPs. For NNPs with two protective shells and pressure release system such as WWER-1000 a comprehensive, passive-mode environmental protection system of decontamination of the radioactive steam-air mixture from the containment and the intercontainment area was suggested. This system includes the “wet” stage (scrubbers, etc.), the “dry” stage (sorption module), and also an ejector, which in a passive mode is capable of solving the multi-purpose task of decontamination of the air-steam mixture. For WWER-440/230 NPPs three protection levels: 1) a jet-vortex condenser; 2) the spray system; 3) a sorption module were suggested and installed. For modern designs of new generation NPPs, which do not provide for pressure release systems, a new passive filtering system together with the passive heat-removal system, which can be used during severe accidents in case all power supply units become unavailable, was proposed and after modernization was installed at the KudanKulam NPP (India).
References
[1]
Kastchiev, G., Kromp, W., Kurth, S., Lochbaum, D., Lyman, E., Sailer, M. and Schneider, M. (2007) An Account of Events in Nuclear Power Plants Since the Chernobyl Accident in 1986. The Greens/European Free Alliance, Brussels.
Hydrogen and Fission Product Issues Relevant for Containment Safety Assessment under Severe Accident Conditions (2010) Report NEA/CSNI R3. OECD, Paris.
[4]
ISP-49 on Hydrogen Combustion (2011) Report NEA/CSNI R9. OECD, Paris.
[5]
Status Report on Hydrogen Management and Related Computer Codes (2014) Report NEA/CSNI R8. OECD, Paris.
[6]
Status Report on Spent Fuel Pools under Loss-of-Cooling and Loss-of-Coolant Accident Conditions (2015) Final Report NEA/CSNI R2. OECD, Paris.
[7]
Schwantes, J.M., Orton, C.R. and Clark, R.A. (2012) Analysis of a Nuclear Accident: Fission and Activation Product Releases from the Fukushima Daiichi Nuclear Facility as Remote Indicators of Source Identification, Extent of Release, and State of Damaged Spent Nuclear Fuel. Environmental Science & Technology, 46, 8621-8627.
https://doi.org/10.1021/es300556m
[8]
Status Report on Filtered Containment Venting (2014) Report NEA/CSNI R7. OECD, Paris.
[9]
Topf, C., Sempere-Belda, L., Fischer, M., Tscheschlok, K. and Volkmann, C. (2013) Full System Decontamination at German Nuclear Power Plant Unterweser. International Journal for Nuclear Power, 58, 216-220.
[10]
Per-formance Analysis of WWER-440/230 Nuclear Power Plants (1997) Report IAEA-TECDOC-922. IAEA, Vienna.
[11]
Slugen, V. (2011) Safety of VVER-440 Reactors: Barriers against Fission Products Release. Springer-Verlag London Limited, London.
https://doi.org/10.1007/978-1-84996-420-3
[12]
Safety Analysis of WWER-440 Nuclear Power Plants: Potential Consequences of a Large Primary to Secondary System Leakage Accident (2009) Report IAEA-TECDOC-1610. IAEA, Vienna.
[13]
Lillington, J.N. (2004) Future of Nuclear Power. Elsevier Ltd., Amsterdam.
[14]
Status of Advanced Light Water Reactor Designs (2004) Report IAEA-TECDOC-1391. IAEA, Vienna.
[15]
Pioro, I. (2016) Handbook of Generation IV Nuclear Reactors. Elsevier, Amsterdam.
Dillman, H.G. and Bunz, H. (1991) Design of a Filter System for PWR Containment Venting. J. Aeros. Sci., 22, S701-S704.
https://doi.org/10.1016/S0021-8502(05)80197-1
[18]
Condensing-Cleaning Device for Aerosols and Volatile Form of Iodine (1995) Promotion Materials, Inter. Exibit. “Nuctek’95”, Moscow, Russia.
[19]
Agrawal, S.K., Chauhan, A. and Mishra, A. (2006) The VVERs at KudanKulam. Nuclear Engineering and Design, 236, 812-835.
https://doi.org/10.1016/j.nucengdes.2005.09.030