Electromagnetic Simulation for the Diagnosis of Lipoprotein Density in Human Blood, a Non-Invasive Approach

DOI: 10.4236/ojab.2017.41001, PP. 1-11

Keywords: Non-Invasive Monitoring, Cholesterol, Electromagnetic, Biosensors, Wearable Devices

Full-Text   Cite this paper   Add to My Lib

Abstract:

With the rise in prevalence of Type II diabetes throughout the world, an increasing need for a portable monitoring system for both blood glucose and lipoprotein concentrations is in demand. Recent work has led to non-invasive wearable devices for monitoring changes in blood glucose concentrations using electromagnetic (EM) waves. However, this still fall short as a means of monitoring cholesterol levels in diabetic patients. The EM study on human tissues emphasized here may also relate to the safety guidelines applied to cellular communications, power lines, and other EM applications. The specific absorption rate (SAR) for the power of the non-ionizing frequency must not exceed a threshold as it impacts DNA and can lead to cancerous tissues. In this study, we used COMSOL software for the investigation of the viability of using EM within the frequency range of 64 MHz-1 GHz as a means of monitoring the transmission properties of human blood and lipoprotein. In this approach, wave equations were solved within blood and lipoprotein boundaries. Research parameters, including frequency range, Power input (SAR), and lipoprotein densities, were investigated. The transmission properties, produced by the electrical and thermal characteristics of these physiological parameters, have led to proper diagnosis of lipoprotein density. Within the frequency range of 64 MHz to 1 GHz, and for a power range of 0.1 to 0.6 SAR, lipoprotein density from 1.00 g/mL to 1.20 g/mL was considered. A 2D model, with an antenna source that supplied the electromagnetic waves to human tissues, was created for the simulations. These were used for the study of the transmission properties of the EM energy into the blood and lipoprotein tissues. While the range of magnetic flux values between simulations varies only slightly or not at all, the distribution of these values is impacted by given parameters. As such, a device capable of comparing magnetic flux values and penetration depths could easily distinguish between samples of different lipoprotein densities. The results obtained in this study can be accommodated non-invasively by human tissues, and can be produced in a practical model using wearable devices. A practical model is proposed for future consideration.

References

[1]  Wu, I.-L., Li, J.-Y. and Fu, C.-Y. (2011) The Adoption of Mobile Healthcare by Hospitals Professionals: An Integrative Perspective. Decision Support Systems, 51, 587-596.
https://doi.org/10.1016/j.dss.2011.03.003
[2]  Rodgers, M.M., Pai, V.M. and Conroy, R.S. (2015) Recent Advances in Wearable Sensors for Health Monitoring. IEEE Sensors Journal, 15, 3119-3126.
https://doi.org/10.1109/JSEN.2014.2357257
[3]  Woodward, R.M., Wallace, V.P., Pye, R.J., Cole, B.E., Arnone, D.D., Linfield, E. and Pepper, M. (2003) Terahertz Pulsed Imaging for Ex Vivo Basal Cell Carcinoma. Journal of Investigative Dermatology, 120, 72-78.
https://doi.org/10.1046/j.1523-1747.2003.12013.x
[4]  Gildea, T.R., et al. (2006) Electromagnetic Navigation Diagnostic Bronchoscopy: A Prospective Study. American Journal of Respiratory and Critical Care Medicine, 174, 982-989.
https://doi.org/10.1164/rccm.200603-344OC
[5]  Jensen, K.W., et al. (2012) Multicenter Experience with Electromagnetic Navigation Bronchoscopy for the Diagnosis of Pulmonary Nodules. Journal of Bronchology & Interventional Pulmonology, 19, 195-199.
https://doi.org/10.1097/LBR.0b013e3182616ece
[6]  Pickwell, E., Cole, B.E., Fitzgerald, A.J., Pepper, M. and Wallace, V.P. (2004) In Vivo Study of Human Skin Using Pulsed Terahertz Radiation. Physics in Medicine and Biology, 49, 1595-1607.
https://doi.org/10.1088/0031-9155/49/9/001
[7]  Agarwal, A., et al. (2008) Effect of Cell Phone Usage on Semen Analysis in Men Attending Infertility Clinic: An Observational Study. Fertility and Sterility, 89, 124-128.
https://doi.org/10.1016/j.fertnstert.2007.01.166
[8]  Hardell, L. and Sage, C. (2008) Biological Effects from Electromagnetic Field Exposure and Public Exposure Standards. Biomedicine & Pharmacotherapy, 62, 104-109.
https://doi.org/10.1016/j.biopha.2007.12.004
[9]  Panagopoulos, D.J., Karabarbounis, A. and Margaritis, L.H. (2002) Mechanism for Action of Electromagnetic Fields on Cells. Biochemical and Biophysical Research Communications, 298, 95-102.
[10]  Bennett, W.R. (1994) Cancer and Power Lines. Physics Today, 47, 23-31.
https://doi.org/10.1063/1.881417
[11]  Yoo, E.-H. and Lee, S.-Y. (2010) Glucose Biosensors: An Overview of Use in Clinical Practice. Sensors, 10, 4558-4576.
[12]  Chung, J., Choi, H.S. and Wong, T.K.S. (2012) Recent Advances in Noninvasive Glucose Monitoring. Medical Devices: Evidence and Research, 5, 45-52.
[13]  Malinin, L. (2012) Development of a Non-Invasive Blood Glucose Monitor Based on Impedance Measurements. International Journal of Biomedical Engineering and Technology, 8, 60.
[14]  Solano, M.P. and Goldberg, R.B. (2006) Lipid Management in Type 2 Diabetes. Clinical Diabetes, 24, 27-32.
https://doi.org/10.2337/diaclin.24.1.27
[15]  Grover, S.A., Coupal, L. and Hu, X. (1995) Identifying Adults at Increased Risk of Coronary Disease How Well Do the Current Cholesterol Guidelines Work? JAMA, 274, 801-806.
https://doi.org/10.1001/jama.1995.03530100041032
[16]  Melzer, M., Mönch, J.I., Makarov, D., Zabila, Y., Cañón Bermúdez, G.S., Karnaushenko, D., Baunack, S., Bahr, F., Yan, C., Kaltenbrunner, M. and Schmidt, O.G. (2015) Wearable Magnetic Field Sensors for Flexible Electronics. Advanced Materials, 27, 1274-1280.
[17]  Sasha, S., Cano-Garcia, H., Sotiriou, I., Lipscombe, O., Gouzouasis, I., Koutsoupidou, M., Palikaras, G., Mackenzie, R., Reeve, T., Kosmas, P. and Efthymios (2017) A Glucose Sensing System Based on Transmission Measurements at Millimeter Waves using Micro strip Patch Antennas. Scientific Reports, 7.
[18]  Collins, C.M., et al. (2004) Temperature and SAR Calculations for a Human Head within Volume and Surface Coils at 64 and 300 MHz. Journal of Magnetic Resonance Imaging, 19, 650-656.
https://doi.org/10.1002/jmri.20041
[19]  Gooch, J.W. (2011) Very Low Density Lipoprotein (VLDL). Encyclopedic Dictionary of Polymers, 931.
https://doi.org/10.1007/978-1-4419-6247-8_15082
[20]  Wang, H., Han, C., Wang, H., Jin, Q., Wang, D., Cao, L. and Wang, G. (2011) Simultaneous Determination of High-Density Lipoprotein, Very Low-Density Lipoprotein and Low-Density Lipoprotein Subclass in Human Serum by Microchip CE. Chromatographia, 74, 799-805.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133