全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Improvement of Fire Extinguishing Performance by Decentralized Supply of Fire-Fighting Agents

DOI: 10.4236/ojsst.2017.73008, PP. 87-95

Keywords: Fire-Fighting, Fire Safety Science, Decentralization

Full-Text   Cite this paper   Add to My Lib

Abstract:

One of the central problems in fire safety science and technology is to reduce damage caused by both fires and fire-fighting processes. This paper provides a potential solution to the problem, and it derives from decentralization of fire-fighting agents. In particular, this paper investigates fire extinguishing performance when a fire-fighting agent is supplied to a fire from one direction with one extinguisher and from two directions with two extinguishers. The two methods are called the centralized supply and the decentralized supply, respectively, in this paper. It is demonstrated that the decentralized supply reduces damage caused by both fires and fire-fighting processes. This follows from the facts that fire extinguishment by the decentralized supply is more certain than the centralized supply, and that the decentralized supply requires less total amount of a fire-fighting agent than the centralized supply for fire extinguishment.

References

[1]  Ni, X., Kuang, K., Yang, D., Jin, X. and Liao, G. (2009) A New Type of Fire Suppressant Powder of NaHCO3/Zeolite Nanocomposites with Core-Shell Structure. Fire Safety Journal, 44, 968-975.
https://doi.org/10.1016/j.firesaf.2009.06.004
[2]  Kim, A. (2011) Advances in Fire Suppression Systems. Construction Technology Updates, 75.
https://www.nrc-cnrc.gc.ca/ctu-sc/files/doc/ctu-sc/ctu-n75_eng.pdf
[3]  Koshiba, Y., Takahashi, Y. and Ohtani, H. (2012) Flame Suppression Ability of Metallocenes (Nickelocene, Cobaltcene, Ferrocene, Manganocene, and Chromocene). Fire Safety Journal, 51, 10-17.
https://doi.org/10.1016/j.firesaf.2012.02.008
[4]  Saito, S., Ogawa, Y., Saso, Y., Liao, C. and Sakei, R. (1996) Flame-Extinguishing Concentrations and Peak Concentrations of N2, Ar, CO2 and Their Mixtures for Hydrocarbon Fuels. Fire Safety Journal, 27, 185-200.
[5]  Senecal, J. (2005) Flame Extinguishing in the Cup-Burner by Inert Gases. Fire Safety Journal, 40, 579-591.
https://doi.org/10.1016/j.firesaf.2005.05.008
[6]  Senecal, J. (2008) Standardizing the Measurement of Minimum Extinguishing Concentrations of Gaseous Agents. Fire Technology, 44, 207-220.
[7]  Grant, G., Brenton, J. and Drysdale, D. (2000) Fire Suppression by Water Sprays. Progress in Energy and Combustion Science, 26, 79-130.
https://doi.org/10.1016/S0360-1285(99)00012-X
[8]  Torikai, H., Narita, M. and Ito, A. (2013) Extinguishment of Pool Fire with Rubber Balloon Inflated with Inert Gas. The 24th International Symposium on Transport Phenomena, 682-688.
[9]  Iwatani, Y. and Torikai, H. (2014) Development and Control of an Aerial Extinguisher with an Inert Gas Capsule. SICE Journal of Control, Measurement, and System Integration, 7, 168-172.
[10]  Iwatani, Y. and Torikai, H. (2015) Flame Extinguishment by Cooperation of Two Aerial Extinguishers. IEEE/SICE International Symposium on System Integration, 534-539.
https://doi.org/10.1109/sii.2015.7405036
[11]  Lattimer, B.Y. (2015) Robotics in Firefighting. Emerging Trends, 100.
http://www.sfpe.org/?page=FPE_ET_Issue_100

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133