The solar photovoltaic (PV) market has grown very rapidly throughout the past 15 years and is quickly becoming an international, non-subsidized market with increased demand for performance certainty. An increasing number of studies analyze long-term monitoring data to determine degradation rates, or “rates of change” (RoCs). Analyses of long-term monitoring data give insight in the performance of PV power plants over time, but are found to be sensitive to uncertainties, especially those related to irradiance measurements using silicon reference cells. The case study analysis shows, however, that the RoCs are much lower if reference cells are adjusted for soiling, drifting and sensor replacements or if satellite irradiance data is used. This indicates that the impact of biased irradiance data should not be underestimated. It was also found, that the distribution of RoCs is strongly influenced by the age and size of the selected systems, underlining the importance of system selection. The case study analysis indicates that crystalline silicon PV systems operating for 8+ years are expected to show a “rate of change” of -0.5% per year or fewer. In this paper the 15-minute data has been collected from a solar photovoltaic generating station installed on the roof of engineering college building and efficiency/degradation of solar panels have been analyzed and reported.
References
[1]
Limmanee, A., Songtrai, S., Udomdachanut, N., Kaewniyompanit, S., Sato, Y., Nakaishi, M., Kittisontirak, S., Sriprapha, K. and Sakamoto, Y. (2017) Degradation Analysis of Photovoltaic Modules under Tropical Climatic Conditions and Its Impacts on LCOE. Renewable Energy, 102, 199-204. https://doi.org/10.1016/j.renene.2016.10.052
[2]
Sharma, V. and Chandel, S.S. (2016) A Novel Study for Determining Early Life Degradation of Multi-Crystalline-Silicon Photovoltaic Modules Observed in Western Himalayan Indian Climatic Conditions. Solar Energy, 134, 32-44. https://doi.org/10.1016/j.solener.2016.04.023
[3]
Balaska, A., Tahri, A., Tahri, F. and Stambouli, A.B. (2017) Performance Assessment of Five Different Photovoltaic Module Technologies under Outdoor Conditions in Algeria. Renewable Energy, 107, 53-60. https://doi.org/10.1016/j.renene.2017.01.057
[4]
Silvestre, S., Kichou, S., Guglielminotti, L., Nofuentes, G. and Alonso-Abella, M. (2016) Degradation Analysis of Thin Film Photovoltaic Modules under Outdoor Long Term Exposure in Spanish Continental Climate Conditions. Solar Energy, 139, 599-607. https://doi.org/10.1016/j.solener.2016.10.030
[5]
Limmanee, A., Udomdachanut, N., Songtrai, S., Kaewniyompanit, S., Sato, Y., Nakaishi, M., Kittisontirak, S., Sriprapha, K. and Sakamoto, Y. (2016) Field Performance and Degradation Rates of Different Types of Photovoltaic Modules: A Case Study in Thailand. Renewable Energy, 89, 12-17. https://doi.org/10.1016/j.renene.2015.11.088
[6]
Bouraiou, A., Hamouda, M., Chaker, A., Mostefaoui, M., Lachtar, S., Sadok, M., Boutasseta, N., Othmani, M. and Issam, A. (2015) Analysis and Evaluation of the Impact of Climatic Conditions on the Photovoltaic Modules Performance in the Desert Environment. Energy Conversion and Management, 106, 1345-1355. https://doi.org/10.1016/j.enconman.2015.10.073
[7]
Rajput, P., Tiwari, G.N. and Sastry, O.S. (2016) Thermal Modelling and Experimental Validation of Hot Spot in Crystalline Silicon Photovoltaic Modules for Real Outdoor Condition. Solar Energy, 139, 569-580. https://doi.org/10.1016/j.enconman.2015.10.073
[8]
Park, N.C., Han, C.W. and Kim, D.H. (2013) Effect of Moisture Condensation on Long-Term Reliability of Crystalline Silicon Photovoltaic Modules. Microelectronics Reliability, 53, 1922-1926. https://doi.org/10.1016/j.microrel.2013.05.004
[9]
Tanesab, J., Parlevliet, D., Whale, J., Urmee, T. and Pryor, T. (2015) The Contribution of Dust to Performance Degradation of PV Modules in a Temperate Climate Zone. Solar Energy, 120, 147-157. https://doi.org/10.1016/j.solener.2015.06.052
[10]
Tossa, A., Soro, Y.M., Thiaw, L., Azoumah, Y., Sicot, L., Yamegueu, D., Lishou, C., Coulibaly, Y. and Razongles, G. (2016) Energy Performance of Different Silicon Photovoltaic Technologies under Hot and Harsh Climate. Energy, 103, 261-270. https://doi.org/10.1016/j.energy.2016.02.133
[11]
Dabou, R., Bouchafaa, F., Arab, A.H., Bouraiou, A., Draou, M.D., Necaibia, A. and Mostefaoui, M. (2016) Monitoring and Performance Analysis of Grid Connected Photovoltaic under Different Climatic Conditions in South Algeria. Energy Conversion and Management, 130, 200-206. https://doi.org/10.1016/j.enconman.2016.10.058
[12]
Abderrezek, M. and Fathi, M. (2017) Experimental Study of the Dust Effect on Photovoltaic Panels’ Energy Yield. Solar Energy, 142, 308-320. https://doi.org/10.1016/j.solener.2016.12.040
[13]
Attari, K., Elyaakoubi, A. and Asselman, A. (2016) Performance Analysis and Investigation of a Grid-Connected Photovoltaic Installation in Morocco. Energy Reports, 2, 261-266. https://doi.org/10.1016/j.egyr.2016.10.004
[14]
Shukla, A.K., Sudhakar, K. and Baredar, P. (2016) Simulation and Performance Analysis of 110 kWp Grid-Connected Photovoltaic System for Residential Building in India: A Comparative Analysis of Various PV Technology. Energy Reports, 2, 82-88. https://doi.org/10.1016/j.egyr.2016.04.001
[15]
Savvakis, N. and Tsoutsos, T. (2015) Performance Assessment of a Thin Film Photovoltaic System under Actual Mediterranean Climate Conditions in the Island of Crete. Energy, 90, 1435-1455. https://doi.org/10.1016/j.energy.2015.06.098
[16]
Ferrada, P., Araya, F., Marzo, A. and Fuentealba, E. (2015) Performance Analysis of Photovoltaic Systems of Two Different Technologies in a Coastal Desert Climate Zone of Chile. Solar Energy, 114, 356-363. https://doi.org/10.1016/j.solener.2015.02.009
[17]
Wang, H.X., Munoz-García, M.A., Moreda, G.P. and Alonso-García, M.C. (2017) Seasonal Performance Comparison of Three Grid Connected Photovoltaic Systems Based on Different Technologies Operating under the Same Conditions. Solar Energy, 144, 798-807. https://doi.org/10.1016/j.solener.2017.02.006
[18]
Ioannou, A.K., Stefanakis, N.E. and Boudouvis, A.G. (2014) Design Optimization of Residential Grid-Connected Photovoltaics on Rooftops. Energy and Buildings, 76, 588-596. https://doi.org/10.1016/j.enbuild.2014.03.019
[19]
Cristaldi, L., Faifer, M., Rossi, M., Toscani, S., Catelani, M., Ciani, L. and Lazzaroni, M. (2014) Simplified Method for Evaluating the Effects of Dust and Aging on Photovoltaic Panels. Measurement, 54, 207-214. https://doi.org/10.1016/j.measurement.2014.03.001
[20]
Sharma, V., Kumar, A., Sastry, O.S. and Chandel, S.S. (2013) Performance Assessment of Different Solar Photovoltaic Technologies under Similar Outdoor Conditions. Energy, 58, 511-518. https://doi.org/10.1016/j.energy.2013.05.068
[21]
Paudyal, B.R. and Shakya, S.R. (2016) Dust Accumulation Effects on Efficiency of Solar PV Modules for off Grid Purpose: A Case Study of Kathmandu. Solar Energy, 135, 103-110. https://doi.org/10.1016/j.solener.2016.05.046