全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Penumbral Dose Characteristics of Physical and Virtual Wedge Profiles

DOI: 10.4236/ijmpcero.2017.62020, PP. 216-224

Keywords: Physical Wedge, Virtual Wedge, Penumbra and Deviations

Full-Text   Cite this paper   Add to My Lib

Abstract:

Purpose: Both physical and virtual wedges are used in radiotherapy to get uniform and desired dose distribution in clinical setting. All linear accelerators of different venders have computer controlled dynamic wedges called virtual wedge filters. Penumbra is one of the important photon beam characteristics needed to be understood in radiation therapy at the time of commissioning of Treatment Planning system (TPS) as well as applying various treatment planning algorithms in clinical applications. In this study we measured the dose profiles of open field, physical wedges (PW) and virtual wedges (VW) for energies (6 MV & 15 MV), various field sizes (10 × 10, 15 × 15 & 20 × 20 cm2), depths (dmax, 10 cm, 20 cm) and wedge angles (15°, 30°, 45° and 60°). From beam profile we calculated the penumbral width for open and wedged fields.

References

[1]  Darby, S.C., Ewertz, M., McGale, P., Bennet, A.M., Blom-Goldman, U., Bronnum, D., Correa, C., Cutter, D., Gagliardi, G., Gigante, B., Jensen, M.B., Nisbet, A., Peto, R., Rahimi, K. and Taylor, C. (2013) Risk of Ischemic Heart Disease in Women After Radiotherapy for Breast Cancer. New England Journal of Medicine, 11, 987-998.
https://doi.org/10.1056/NEJMoa1209825
[2]  Bhatnagar, A.K., Brandner, E., Sonnik, D., Wu, A., Kalnicki, S. and Deutsch, M. (2006) Intensity Modulated Radiation Therapy (IMRT) Reduces the Dose to the Contralateral Breast When Compared to Conventional Tangential Fields for Primary Breast Irradiation. Breast Cancer Research and Treatment, 1, 41-46.
https://doi.org/10.1007/s10549-005-9032-8
[3]  Ling, T.C., et al. (2016) Analysis of Intensity-Modulated Radiation Therapy (IMRT), Proton and 3D Conformal Radiotherapy (3D-CRT) for Reducing Perioperative Cardiopulmonary Complications in Esophageal Cancer Patients. Cancers (Basel), 6, 2356-2368.
https://doi.org/10.3390/cancers6042356
[4]  Xie, X., Ouyang, S., Wang, H., Yang, W., Jin, H., Hu, B. and Shen, L. (2014) Dosimetric Comparison of Left-Sided Whole Breast Irradiation with 3D-CRT, IP-IMRT and Hybrid IMRT. Oncology Reports, 31, 2195-2205.
[5]  Wolff, D., Stieler, F., Welzel, G., Lorenz, F., Abo-Madyan, Y., Mai, S., Herskind, C., Polednik, M., Steil, V. and Wenz, F. (2015) Comparison of Hybrid Volumetric Modulated Arc Therapy (VMAT) Technique and Double Arc VMAT Technique in the Treatment of Prostate Cancer. Radiology and Oncology, 49, 291-298.
[6]  Pdgorsak, E.B. (2005) Radiation Oncology Physics: A Hand Book for Teachers and Students. International Atomic Energy Agency, Vienna.
[7]  Schlegel, A.L., Bortfeld, T. and Grosu, A.L. (2006) New Technologies in Radiation Oncology. Springer, Berlin.
https://doi.org/10.1007/3-540-29999-8
[8]  Khan, F.M. (2003) Physics of Radiation Therapy. 3rd Edition, Lippincott Williams & Wilkins, Philadelphia.
[9]  Pastyr, O., Echner, G., Hartmann, G.H. and Richter, J. (2011) Dynamic Edge Focussing: A New MLC-Design to Deliver IMRT with a Double Focussing High Precision Multi-Leaf Collimator. Journal of Radiotherapy & Medical Oncology, 61, 624-643.
[10]  Butson, M.J., Yu, P.K.N. and Cheung, T. (2003) Rounded End Multi-Leaf Penumbral Measurements with Radiochromic Film. Physics in Medicine and Biology, 48, 247-252.
https://doi.org/10.1088/0031-9155/48/17/402
[11]  Cherry, P. (2009) Practical Radiotherapy: Physics and Equipment. 2nd Edition, Wiley-Blackwell, Hoboken.
[12]  Mohan, R., Arnfield, M., Tong, S. and Wu, Q. (2000) The Impact of Fluctuations in Intensity Patterns on the Number of Monitor Units and the Quality and Accuracy of Intensity Modulated Radiotherapy. Journal of Medical Physics, 27, 1226-1237.
https://doi.org/10.1118/1.599000
[13]  Grigorov, G.N. and Chow, J.C. (2016) Leakage-Penumbra Effect in Intensity Modulated Radiation Therapy Step-and-Shoot Dose Delivery. World Journal of Radiology, 8, 73-81.
https://doi.org/10.4329/wjr.v8.i1.73
[14]  Attalla, E.M., Abo-Elenein, H.S., Ammar, H. and El-Desoky, I. (2010) Comparison of Dosimetric Characteristics of Siemens Virtual and Physical Wedges for ONCOR Linear Accelerator. Journal of Medical Physics, 35.
[15]  Christopher, F.N. and Suh, T.S. (2016) Radiotherapy Using Hard Wedges Is No Longer Appropriate and Should Be Discontinued. AAPM, Medical Physics, 43, 1031.
https://doi.org/10.1118/1.4939262
[16]  Canadian Partnership for Quality Radiotherapy (2016) Technical Quality Control Guidelines for Medical Linear Acclerators and Mulitleaf Collimators. www.cpqr.ca