The safety of water is usually determined by comparing its quality to recommended standards. The objective of this work was to determine whether the water supplied on Njala Campus is safe for drinking. The quality parameters investigated include coliform bacteria, turbidity, conductivity, total dissolved solids and nitrates. Samples were stored in a cooler with ice and transported to the laboratory within 30 minutes of collection. A checklist of questions to know the perception of residents was administered. According to the physical and biological results, the water is not safe for consumption. The turbidity and microbial counts were too high in most samples both in the wet and dry seasons. Additionally, over 80% of the respondents did not trust the water supply system. Most of them treat the supplied water by either boiling or disinfection before use. Most respondents complained of water-borne diseases but were not clear whether it is related to the water supplied. The chemical parameters, however, were acceptable: nitrate levels were low. In conclusion, the water is not safe for consumption as far as the physical and biological parameters are concerned. The campus water supply system needs improvement in terms of conveying raw and finished water, filter optimization, and satisfying the chlorine demand.
References
[1]
Washington State DOH (2016) Coliform Bacteria and Drinking Water.
http://www.doh.wa.gov/portals/1/Documents/Pubs/331-181.pdf
[2]
SON (2007) Nigerian Standard for Drinking Water Quality. Sttandard Organization Nigeria (SON).
[3]
GSB (2009) Water Quality Specification for Drinking Water. 3rd Edition, Ghana Standards Board, Accra.
[4]
WHO (2011) Guidelines for Drinking-Water Quality. 4th Edition, World Health Organization.
[5]
Fawell, J.K. (2002) Asbestos Cement Drinking Water Pipes and Possible Health Risks. Devizes, Wiltshire.
[6]
Nyallay, M.R. (2011) Taia River Regime Water Quality Assessment, Taiama Highway Bridge to Waifor Crossing. Njala University, Njala.
[7]
Robert, E., Grippa, M., Kergoat, L., Pinet, S., Gal, L., Cochonneau, G. and Martinez, J.-M. (2016) Monitoring Water Turbidity and Surface Suspended Sediment Concentration of the Bagre Reservoir (Burkina Faso) Using MODIS and Field Reflectance Data. International Journal of Applied Earth Observation and Geoinformation, 52, 243-251. https://doi.org/10.1016/j.jag.2016.06.016
[8]
Stauber, C.E., Elliott, M.A., Koksal, F., Ortiz, G.M., DiGiano, F.A. and Sobsey, M.D. (2006) Characterisation of the Biosand Filter for E. coli Reductions from Household Drinking Water under Controlled Laboratory and Field Use Conditions. Water Sci- ence and Technology, 54, 1-7. https://doi.org/10.2166/wst.2006.440
[9]
WHO (2003) Total Dissolved Solids in Drinking-Water. World Health Organization, Geneva.
[10]
McHenry, M.P. (2013) Hybrid Microalgal Biofuel, Desalination, and Solution Mining Systems: Increased Industrial Waste Energy, Carbon, and Water Use Efficiencies. Mitigation and Adaptation Strategies for Global Change, 18, 159-167.
https://doi.org/10.1007/s11027-012-9361-y
[11]
Ghimire, N.P., Caravello, G.U. and Jha, P.K. (2013) Bacterial Contamination in the Surface Water Bodies in Sagarmatha National Park and Buffer Zone, Nepal. Scientific World, 11, 94-96. https://doi.org/10.3126/sw.v11i11.8560
[12]
Angeloudis, A., Stoesser, T. and Falconer, R.A. (2014) Predicting the Disinfection Efficiency Range in Chlorine Contact Tanks through a CFD-Based Approach. Water Research, 60, 118-129. https://doi.org/10.1016/j.watres.2014.04.037
[13]
Angeloudis, A., Stoesser, T., Falconer, R.A. and Kim, D. (2015) Flow, Transport and Disinfection Performance in Small- and Full-Scale Contact Tanks. Hydro-Environment Research, 9, 15-27. https://doi.org/10.1016/j.jher.2014.07.001
[14]
de Queiroz, J.T.M., Doria, M.D.F., Rosenberg, M.W., Heller, L. and Zhouri, A. (2013) Perceptions of Bottled Water Consumers in Three Brazilian Municipalities. Water and Health, 11, 520-531. https://doi.org/10.2166/wh.2013.222