A Half-Arc Multiple Deep-Inspiration Breath-Hold Volumetric Modulated Arc Therapy for a Lung Tumor with 10 MV Flattening-Filter-Free Beams and an Image Sensor Measuring a Distance Map to Thorax Surface: An Initial Clinical Experience

DOI: 10.4236/ijmpcero.2017.61004, PP. 31-35

Keywords: Deep Inspiration Breath-Hold, DIBH, FFF, VMAT, Kinect, Lung

Full-Text   Cite this paper   Add to My Lib

Abstract:

A technique for multiple deep-inspiration breath-hold (DIBH) volumetric modulated arc therapy (VMAT) for a lung tumor has been proposed with 10 MV flattening-filter-free beams and an image sensor measuring a distance map to thorax surface. Planning CT images were acquired under a DIBH condition and a clinical target volume (CTV) was contoured. This procedure was repeated five times and an internal target volume (ITV) among the multiple DIBHs was created by integrating the five CTVs. A planning target volume (PTV) was defined by adding an isotropic margin of 5 mm to the ITV. Immediately before treatment, a 30-second half-arc cone-beam computer tomography (CBCT) imaging was performed under another DIBH condition, and the couch was repositioned so that tumor may be located inside the PTV contours. An infrared distance measurement device having laser diodes and an image sensor was attached to the couch, and a distance map to the patient thorax surface was recorded as a reference during still another DIBH condition. A half-arc segmented VMAT beams with two beam interrupts were delivered to the patient under multiple DIBHs, where the delivery time of each of the three segmented beams was 30 seconds. During the beam delivery, the distance map was monitored in real time to confirm that the distance to the thorax surface remained unchanged. In-treatment CBCT images suggested that the tumor position at the time of tumor registration was accurately reproduced during the DIBH VMAT delivery.

References

[1]  Boda-Heggemann, J., Knopf, A.C., Simeonova-Chergou, A., Wertz, H., Stieler, F., Jahnke, A., Jahnke, L., Fleckenstein, J., Vogel, L., Arns, A., Blessing, M., Wenz, F. and Lohr, F. (2016) Deep Inspiration Breath Hold-Based Radiation Therapy: A Clinical Review. International Journal of Radiation Oncology * Biology * Physics, 94, 478-492.
https://doi.org/10.1016/j.ijrobp.2015.11.049
[2]  Wong, J.W., Sharpe, M.B., Jaffray, D.A., Kini, V.R., Robertson, J.M., Stromberg, J.S. and Martinez, A.A. (1999) The Use of Active Breathing Control (ABC) to Reduce Margin for Breathing Motion. International Journal of Radiation Oncology * Biology * Physics, 44, 911-919.
https://doi.org/10.1016/S0360-3016(99)00056-5
[3]  Bartlett, F.R., Colgan, R.M., Donovan, E.M., Carr, K., Landeg, S., Clements, N., McNair, H.A., Locke, I., Evans, P.M., Haviland, J.S., Yarnold, J.R. and Kirby, A.M. (2014) Voluntary Breath-Hold Technique for Reducing Heart Dose in Left Breast Radiotherapy. Journal of Visualized Experiments, 89, e51578.
https://doi.org/10.3791/51578
[4]  Onishi, H., Kawakami, H., Marino, K., Komiyama, T., Kuriyama, K., Araya, M., Saito, R., Aoki, S. and Araki, T. (2010) A Simple Respiratory Indicator for Irradiation during Voluntary Breath Holding: A One-Touch Device without Electronic Materials. Radiology, 255, 917-923.
https://doi.org/10.1148/radiol.10090890
[5]  Sarbolandi, H., Lefloch, D. and Kolb, A. (2015) Kinect Range Sensing: Structured-Light versus Time-of-Flight Kinect. Computer Vision and Image Understanding, 139, 1-20.
https://doi.org/10.1016/j.cviu.2015.05.006

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133