全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Preliminary Clinical Outcomes after Implantation of Newer-Generation Biodegradable Polymer-Coated Everolimus-Eluting Stent in “Real-World” Patients with Coronary Artery Disease

DOI: 10.4236/wjcd.2016.612050, PP. 468-476

Keywords: Drug-Eluting Stents, Everolimus, Biodegradable Polymer, Treatment Outcome

Full-Text   Cite this paper   Add to My Lib

Abstract:

Background and Objective: In the contemporary practice, the use of drug-eluting stents is still associated with low mortality benefits, restenosis and stent thrombosis. To address these issues, newer generation, thin-strut, biodegradable polymer coated stents has been designed. Thus, the aim of the study is to assess the safety and clinical performance of the Everoflex (Sahajanand Medical Technologies Pvt. Ltd., Surat, India), a newer generation biodegradable polymer coated everolimus-eluting stent, in unselected “real-world” patients with coronary artery disease. Methods: It is a multicentre, retrospective, non-randomized, single-arm study enrolling all the consecutive patients who underwent implantation with the Everoflex for coronary artery disease from April 2014 to March 2016. The primary end-point of the study is 30-day major adverse cardiovascular events (MACE) rate, which consists of cardiac death, myocardial infarction, target lesion revascularization and target vessel revascularization. Stent thrombosis was also analyzed and reported. Results: A total of 340 patients were intervened successfully with 395 everolimus eluting stents (1.3 ± 0.6 stents per patient). Out of total patients (58.7 ± 10.5 years), 77.9% were male and comorbidities like diabetes and hypertension were observed in 31.2% and 35.3% patients, respectively. According to ACC/AHA classification, there were 34.4% type B lesions and 53.2% type C lesions, indicating a higher proportion of complexity involved. Moreover, 57.9% patients had multivessel disease and there were 15.4% total occlusions. At 30 days, follow-up was completed in 100% patients. The MACE was found to be 1.5%, which is a composite of 1.2% cardiac death and 0.3% target lesion revascularization. Stent thrombosis at 30 days was found to be 0.3%. Conclusion: The low incidence of MACE and stent thrombosis clearly depicts excellent safety and clinical performance of the Everoflex in unselected real world patients with coronary artery disease.

References

[1]  Kastrati, A., Mehilli, J., Pache, J., Kaiser, C., Valgimigli, M., Kelbæk, H., et al. (2007) Analysis of 14 Trials Comparing Sirolimus-Eluting Stents with Bare-Metal Stents. New England Journal of Medicine, 356, 1030-1039.
https://doi.org/10.1056/NEJMoa067484
[2]  Stettler, C., Allemann, S., Wandel, S., Kastrati, A., Morice, M.C., Schomig, A., et al. (2008) Drug Eluting and Bare Metal Stents in People with and without Diabetes: Collaborative Network Meta-Analysis. British Medical Journal, 337, a1331.
https://doi.org/10.1136/bmj.a1331
[3]  Camenzind, E., Steg, P.G. and Wijns, W. (2007) A Cause for Concern. Circulation, 115, 1440-1455.
https://doi.org/10.1161/CIRCULATIONAHA.106.666800
[4]  Wenaweser, P., Daemen, J., Zwahlen, M., van Domburg, R., Jüni, P., Vaina, S., et al. (2008) Incidence and Correlates of Drug-Eluting Stent Thrombosis in Routine Clinical Practice: 4-Year Results from a Large 2-Institutional Cohort Study. Journal of the American College of Cardiology, 52, 1134-1140.
https://doi.org/10.1016/j.jacc.2008.07.006
[5]  Stone, G.W., Midei, M., Newman, W., Sanz, M., Hermiller, J.B., Williams, J., et al. (2008) Comparison of an Everolimus-Eluting Stent and a Paclitaxel-Eluting Stent in Patients with Coronary Artery Disease: A Randomized Trial. JAMA, 299, 1903-1913.
https://doi.org/10.1001/jama.299.16.1903
[6]  Baber, U., Mehran, R., Sharma, S.K., Brar, S., Yu, J., Suh, J.-W., et al. (2011) Impact of the Everolimus-Eluting Stent on Stent Thrombosis: A Meta-Analysis of 13 Randomized Trials. Journal of the American College of Cardiology, 58, 1569-1577.
https://doi.org/10.1016/j.jacc.2011.06.049
[7]  Palmerini, T., Kirtane, A.J., Serruys, P.W., Smits, P.C., Kedhi, E., Kereiakes, D., et al. (2012) Stent Thrombosis with Everolimus-Eluting Stents Meta-Analysis of Comparative Randomized Controlled Trials. Circulation: Cardiovascular Interventions, 5, 357-364.
https://doi.org/10.1161/circinterventions.111.967083
[8]  Palmerini, T., Biondi-Zoccai, G., Della Riva, D., Stettler, C., Sangiorgi, D., D’Ascenzo, F., et al. (2012) Stent Thrombosis with Drug-Eluting and Bare-Metal Stents: Evidence from a Comprehensive Network Meta-Analysis. The Lancet, 379, 1393-1402.
https://doi.org/10.1016/S0140-6736(12)60324-9
[9]  de Waha, A., Cassese, S., Park, D.-W., Burzotta, F., Byrne, R.A., Tada, T., et al. (2012) Everolimus-Eluting versus Sirolimus-Eluting Stents: An Updated Meta-Analysis of Randomized Trials. Clinical Research in Cardiology, 101, 461-467.
https://doi.org/10.1007/s00392-012-0414-8
[10]  King, S.B., Smith, S.C., Hirshfeld, J.W., Jacobs, A.K., Morrison, D.A., Williams, D.O., et al. (2008) 2007 Focused Update of the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention. A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines: 2007 Writing Group to Review New Evidence and Update the ACC/AHA/SCAI 2005 Guideline Update for Percutaneous Coronary Intervention, Writing on Behalf of the 2005 Writing Committee. Circulation, 117, 261-295. https://doi.org/10.1161/CIRCULATIONAHA.107.188208
[11]  Grouve, E. and Kristensen, S. (2007) Stent Thrombosis: Definitions, Mechanisms and Prevention. E-Journal of Cardiology Practice, 32.
[12]  Schuler, W., Sedrani, R., Cottens, S., Häberlin, B., Schulz, M., Schuurman, H.-J., et al. (1997) SDZ RAD, a New Rapamycin Derivative: Pharmacological Properties in Vitro and in Vivo. Transplantation, 64, 36-42.
https://doi.org/10.1097/00007890-199707150-00008
[13]  Grube, E., Sonoda, S., Ikeno, F., Honda, Y., Kar, S., Chan, C., et al. (2004) Six- and Twelve- Month Results from First Human Experience Using Everolimus-Eluting Stents with Bioabsorbable Polymer. Circulation, 109, 2168-2171.
https://doi.org/10.1161/01.CIR.0000128850.84227.FD
[14]  de Waha, A., Dibra, A., Byrne, R.A., Ndrepepa, G., Mehilli, J., Fusaro, M., et al. (2011) Everolimus-Eluting versus Sirolimus-Eluting Stents a Meta-Analysis of Randomized Trials. Circulation: Cardiovascular Interventions, 4, 371-377.
https://doi.org/10.1161/circinterventions.111.963256
[15]  Park, K.W., Kang, S.-H., Velders, M.A., Shin, D.-H., Hahn, S., Lim, W.-H., et al. (2013) Safety and Efficacy of Everolimus-Versus Sirolimus-Eluting Stents: A Systematic Review and Meta-Analysis of 11 Randomized Trials. American Heart Journal, 165, 241-250.
[16]  Sullivan, T.M., Ainsworth, S.D., Langan, E.M., Taylor, S., Snyder, B., Cull, D., et al. (2002) Effect of Endovascular Stent Strut Geometry on Vascular Injury, Myointimal Hyperplasia, and Restenosis. Journal of Vascular Surgery, 36, 143-149.
https://doi.org/10.1067/mva.2002.122878
[17]  Hara, H., Nakamura, M., Palmaz, J.C. and Schwartz, R.S. (2006) Role of Stent Design and Coatings on Restenosis and Thrombosis. Advanced Drug Delivery Reviews, 58, 377-386.
https://doi.org/10.1016/j.addr.2006.01.022
[18]  Kastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schuhlen, H., Neumann, F.J., et al. (2001) Intracoronary Stenting and Angiographic Results: Strut Thickness Effect on Restenosis Outcome (ISAR-STEREO) Trial. Circulation, 103, 2816-2821.
https://doi.org/10.1161/01.CIR.103.23.2816
[19]  Briguori, C., Sarais, C., Pagnotta, P., Liistro, F., Montorfano, M., Chieffo, A., et al. (2002) In-Stent Restenosis in Small Coronary Arteries: Impact of Strut Thickness. Journal of the American College of Cardiology, 40, 403-409.
https://doi.org/10.1016/S0735-1097(02)01989-7

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133