全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

Continuous Vagus Nerve Monitoring during Carotid Endarterectomy

DOI: 10.4236/ojmn.2017.71001, PP. 1-9

Keywords: Carotid Endarterectomy, Vagus Nerve, Vocal Fold, Neuromonitoring, Complication

Full-Text   Cite this paper   Add to My Lib

Abstract:

Backgrounds: Injury to the vagus nerve or one of its branches during carotid endarterectomy can result in vocal fold paralysis but the exact mechanism of injury responsible for vocal fold paralysis after carotid endarterectomy is unclear. Aims: This study was performed to identify potential predictors of vagus nerve injury and obtain feedback by application of intraoperative continuous vagus nerve monitoring. Materials and Methods: Seventy-four patients undergoing carotid endarterectomy were enrolled. A new vagus nerve electrode was designed for less invasive continuous vagus nerve stimulation and monitoring of the vocal fold electromyogram without disturbing the surgical procedure. The device was rectangular (13 mm × 9 mm), with two small round electrodes set on a flexible silicon plate and tube. The electrode was fully implantable during carotid endarterectomy and was positioned at the most distal site of the vagus nerve by suturing to the connective tissue without nerve dissection. All patients underwent laryngoscopy to assess postoperative vocal fold and pharyngeal wall palsy at one week after carotid endarterectomy. Results: Sudden loss of the vocal fold electromyogram was noted in two patients (during plaque removal and during arterial wall suture in one each). In these two patients, incomplete vocal fold and pharyngeal palsy was confirmed by laryngoscopy. The cause of vagus nerve injury may have been traction at the time of distal internal carotid artery manipulation. The vocal fold electromyogram remained normal during the operation in the other 72 patients. However laryngoscopy revealed postoperative vocal fold and pharyngeal palsy in six patients. These findings suggested that delayed vagus nerve injury can occur after carotid endarterectomy. Conclusion: The continuous vagus nerve monitoring may be worthwhile for elucidating the mechanism of vagus nerve injury related to carotid endarterectomy.

References

[1]  Featherstone, R.L., Brown, M.M. and Coward, LJ. (2004) International Carotid Stenting Study: Protocol for a Randomised Clinical Trial Comparing Carotid Stenting with Endarterectomy in Symptomatic Carotid Artery Stenosis. Cerebrovascular Diseases, 18, 69-74.
https://doi.org/10.1159/000078753
[2]  Silver, F.L., Mackey, A., Clark, W,M,. Brooks, W., Timaran, C.H., Chiu, D., Goldstein, L.B., Meschia, J.F., Ferguson, R.D., Moore, W.S., Howard, G. and Brott, T.G. (2011) Safety of Stenting and Endarterectomy by Symptomatic Status in the Carotid Revascularization Endarterectomy Versus Stenting Trial (CREST). Stroke, 42, 675-680.
https://doi.org/10.1161/STROKEAHA.110.610212
[3]  Curran, A.J., Smyth, D., Sheehan, S.J., Joyce, W., Hayes, D.B. and Walsh, M.A. (1997) Recurrent Laryngeal Nerve Dysfunction Following Carotid Endarterectomy. J R Coll Surg Edinb, 42, 168-170.
[4]  Beasley, W.D. and Gibbons, C.P. (2008) Cranial Nerve Injuries and the Retrojugular Approach in Carotid Endarterectomy. Ann R Coll Surg Engl, 90, 685-688.
https://doi.org/10.1308/003588408X318138
[5]  Chiang, F.Y., Lu, I.C., Kuo, W.R., Lee, K.W., Chang, N.C. and Wu, C.W. (2008) The Mechanism of Recurrent Laryngeal Nerve Injury during Thyroid Surgery—The Application of Intraoperative Neuromonitoring. Surgery, 143, 743-749.
https://doi.org/10.1016/j.surg.2008.02.006
[6]  Roberts, J.W. (2008) Elucidating Mechanisms of Recurrent Laryngeal Nerve Injury during Thyroidectomy and Parathyroidectomy. Journal of the American College of Surgeons, 206, 123-130.
https://doi.org/10.1016/j.jamcollsurg.2007.07.017
[7]  Tomonori, T., Minoru, K., Norihiro, S., Katsuya, U., Takayuki, K. and Yoji, N. (2012) Vagus Nerve Neuromonitoring during Carotid Endarterectomy. Perspectives in Vascular Surgery and Endovascular Therapy, 24, 137-140.
https://doi.org/10.1177/1531003512472239
[8]  Tamaki, T., Node, Y., Saitou, N., Saigusa, H., Yamazaki, M. and Morita, A. (2013) Vernet’s Syndrome after Carotid Endarterectomy. Perspectives in Vascular Surgery and Endovascular Therapy, 25, 65-68.
https://doi.org/10.1177/1531003514525476
[9]  Tamaki, T., Node, Y., Saitou, N. and Saigusa, H. (2013) Observation of Vocal Fold and Pharyngeal Paralysis after Carotid Endarterectomy Using a Magnifying Laryngoscope. World Journal of Surgery, 37, 911-914.
https://doi.org/10.1007/s00268-013-1920-1
[10]  Giovagnorio, F. and Martinoli, C. (2001) Sonography of the Cervical Vagus Nerve: Normal Appearance and Abnormal Findings. American Journal of Roentgenology, 76, 745-749.
https://doi.org/10.2214/ajr.176.3.1760745
[11]  Ha, E.J., Baek, J.H., Lee, J.H., Kim, J.K. and Shong, Y.K. (2011) Clinical Significance of Vagus Nerve Variation in Radiofrequency Ablation of Thyroid Nodules. European Radiology, 21, 2151-2157.
https://doi.org/10.1007/s00330-011-2167-6
[12]  Dionigi, G., Chiang, F.Y., Rausei, S., Wu, C.W., Boni, L., Lee, K.W., Rovera, F., Cantone, G. and Bacuzzi, A. (2010) Surgical Anatomy and Neurophysiology of the Vagus Nerve (VN) for Standardised Intraoperative Neuromonitoring (IONM) of the Inferior Laryngeal Nerve (ILN) during Thyroidectomy. Langenbeck’s Archives of Surgery, 395, 893-899.
https://doi.org/10.1007/s00423-010-0693-3
[13]  Lorenz, K., Sekulla, C., Schelle. J., Schmeiss. B., Brauckhoff, M. and Dralle, H. (2010) What Are Normal Quantitative Parameters of Intraoperative Neuromonitoring (IONM) in Thyroid Surgery? Langenbeck’s Archives of Surgery, 395, 901-909.
https://doi.org/10.1007/s00423-010-0691-5
[14]  Jatzko, B., Vytiska-Bistorfer, E., Pawlik, A., Promberger, R., Mayerhofer, K. and Ott, J. (2014) The Impact of Thyroid Function on Intrauterine Insemination Outcome— A Retrospective Analysis. Reproductive Biology and Endocrinology [Serial Online]; 12, 28. http://www.rbej.com/content/12/1/28
https://doi.org/10.1186/1477-7827-12-28
[15]  Agnew, W.F. and McCreery, D.B. (1990) Considerations for Safety with Chronically Implanted Nerve Electrodes. Epilepsia, 31, 27-32.
https://doi.org/10.1111/j.1528-1157.1990.tb05845.x
[16]  Bernards, C.M. (2004) An Unusual Cause of Airway Obstruction during General Anesthesia with a Laryngeal Mask Airway. Anesthesiology, 100, 1017-1018.
https://doi.org/10.1097/00000542-200404000-00037
[17]  Groves, D.A. and Brown, V.J. (2005) Vagal Nerve Stimulation: A Review of Its Applications and Potential Mechanisms That Mediate Its Clinical Effects. Neuro-science & Biobehavioral Reviews, 29, 493-500.
https://doi.org/10.1016/j.neubiorev.2005.01.004
[18]  Dralle, H., Sekulla, C., Haerting, J., Timmermann, W., Neumann, H.J., Kruse, E., Grond, S., Mühlig, H.P., Richter, C., Voss, J., Thomusch, O., Lippert, H., Gastinger, I., Brauckhoff, M. and Gimm, O. (2004) Risk Factors of Paralysis and Functional Outcome after Recurrent Laryngeal Nerve Monitoring in Thyroid Surgery. Surgery, 136, 1310-1322.
https://doi.org/10.1016/j.surg.2004.07.018
[19]  Ulmer, C., Friedrich, C., Kohler, A., Rieber, F., Basar, T., Deuschle, M., Thon, K.P. and Lamadé, W. (2011) Impact of Continuous Intraoperative Neuromonitoring on Autonomic Nervous System during Thyroid Surgery. Head Neck, 33, 976-984.
https://doi.org/10.1002/hed.21564

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133