Abstract:

水氡模拟测量是一种主要依靠人工采样操作提取观测样本的测量手段,在观测完成后,密闭在闪烁室内的放射性气体必须全部排出,以达到闪烁室内气体成分与自然空气相近。当前使用的排气方法效率较低,在气温低、气体密度高等某些特殊情况下的排气效果不理想。长期工作经验积累发现,使闪烁室排气过程在【真空-进气】的状态下循环排气,用于脱气的定时自动控制进气/闭气的装置可以大幅提升排气效率、减小测量误差、提升工作效率、延长真空泵使用寿命。
The water radon simulation test is a kind of measurement, mainly relying on manual sampling operation to extract observed sample. After the observation, the radioactive gas sealed in the scin-tillation chamber must be completely discharged in order to let the indoor gas components be similar to the natural air. The exhaust method currently used has lower efficiency, and the emission effect is not ideal in some special cases such as the low temperature and higher gas density. Through the long-term accumulation of working experience, the author found that in scintillation chamber, if cycle exhaust was made under the status of [vacuum-inlet], the device of automatic timing control of intake/closing means used for degassing gas emissions can improve efficiency, reduce the measurement error, improve work efficiency and extend the service life of the vacuum pump.

References

[1]  中国地震局监测预报司. 地震监测仪器大全[M]. 北京: 地震出版社, 2008: 254-287.
[2]  国家地震局监测预报司. 地震地下流体理论基础与观测技术[M]. 北京: 地震出版社, 2009.
[3]  中国地震局. 地震地下流体观测技术规范[S]. 北京: 地震出版社, 2001: 2-14.
[4]  中国地震局监测预报司.地球物理学概论[M]. 北京: 地震出版社, 2009: 10-31.
[5]  马铭志. 丰满地震台水氡观测因素影响分析[J]. 科技信息, 2012(7): 655.
[6]  刘学领, 等. 水氡观测样品脱气温度及脱气时间的选取[J]. 地震地磁观测与研究, 2008, 29(2): 55-58.
[7]  周超群. 电磁阀的工作原理及其在工程设计应用中的探讨[J]. 石油化工自动化, 2006(5): 92-94.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133