Objective: To analyze the accuracy and specificity of recent studies to compare the ability of predicting fluid responsiveness with Passive Leg Raising (PLR) by using invasive or non-invasive techniques during passive leg raising. Data Sources: MEDLINE, EMBASE and the Cochrane Database of Systematic Reviews were systematically searched. Study Selection: Clinical trials that reported the sensitivity, specificity and area under the receiver operating characteristic curve (AUC) between the responder and non-responder induced by passive leg raising and Volume Expansion (VE) in critical ill patients were selected. 246 studies were screened, 14 studies were included for data extraction, which met our inclusion criteria. Data Extraction: Data were abstracted on study characteristics, patient population, type and amount of VE, time of VE, definition of responders, position, techniques used for measuring hemodynamic change, number and percentage of responders, the correlation coefficient, sensitivity, specificity, best threshold and area under the ROC curve (AUC). Meta-analytic techniques were used to summarize the data. Data Synthesis: A total of 524 critical ill patients from 14 studies were analyzed. Data are reported as point estimate (95% confidence intervals). The pooled sensitivity and specificity of invasive techniques were 80% (73% - 85%) and 89% (84% - 93%) respectively with the area under the sROC of 0.94. While, the pooled sensitivity and specificity of non-invasive techniques were 88% (84% - 92%) and 91% (86% - 94%) respectively with the area under the sROC of 0.95. The pooled DOR of invasive techniques was 32.2 (13.6 - 76.8), which was much lower than that of non-invasive techniques with the value of 64.3 (33.9 - 121.7). Conclusions: The hemodynamic indexes changes induced by PLR could reliably predict fluid responsiveness. Non-invasive hemodynamic techniques with their accuracy and safety can benefit the daily work in ICUs. Because the number of patients included in the present trials was small, further studies should be undertaken to confirm these findings.
References
[1]
Michard, F. and Teboul, J.L. (2002) Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest, 121, 2000-2008. http://dx.doi.org/10.1378/chest.121.6.2000
[2]
Rutlen, D.L., Wackers, F.J. and Zaret, B.L. (1981) Radionuclide assessment of peripheral intravascular capacity: A technique to measure intravascular volume changes in the capacitance circulation in man. Circulation, 64, 146-152. http://dx.doi.org/10.1161/01.CIR.64.1.146
[3]
Marik, P.E., Monnet, X. and Teboul, J.L. (2011) Hemodynamic Parameters to Guide Fluid Therapy. Annals of Intensive Care, 1, 1. http://dx.doi.org/10.1186/2110-5820-1-1
[4]
Monnet, X. and Teboul, J.L. (2008) Passive Leg Raising. Intensive Care Medicine, 34, 659-663. http://dx.doi.org/10.1007/s00134-008-0994-y
[5]
Bossuyt, P.M., Reitsma, J.B., Bruns, D.E., et al. (2003) The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration. Annals of Internal Medicine, 138, W1-W12. http://dx.doi.org/10.7326/0003-4819-138-1-200301070-00012-w1
[6]
Whiting, P.F., Rutjes, A.W.S., Westwood, M.E., et al. (2011) QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies. Annals of Internal Medicine, 155, 529-536. http://dx.doi.org/10.7326/0003-4819-155-8-201110180-00009
[7]
Whiting, P., Rutjes, A.W., Reitsma, J.B., Glas, A.S., Bossuyt, P.M.M. and Kleijnen, J. (2004) Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review. Annals of Internal Medicine, 140, 189-202. http://dx.doi.org/10.7326/0003-4819-140-3-200402030-00010
[8]
Devillé, W.L., Buntinx, F., Bouter, L.M., et al. (2002) Conducting Systematic Reviews of Diagnostic Studies: Didactic Guidelines. BMC Medical Research Methodology, 2, 9. http://dx.doi.org/10.1186/1471-2288-2-9
[9]
Moses, L.E., Shapiro, D. and Littenberg, B. (1993) Combining independent Studies of a Diagnostic Test into a Summary ROC Curve: Data-Analytic Approaches and Some Additional Considerations. Statistics in Medicine, 12, 1293-1316. http://dx.doi.org/10.1002/sim.4780121403
[10]
Egger, M., Smith, G.D., Schneider, M. and Minder, C. (1997) Bias in Meta-Analysis Detected by a Simple, Graphical Test. BMJ, 315, 629-634. http://dx.doi.org/10.1136/bmj.315.7109.629
[11]
Begg, C.B. and Mazumdar, M. (1994) Operating Characteristics of a Rank Correlation Test for Publication Bias. Biometrics, 1088-1101. http://dx.doi.org/10.2307/2533446
[12]
Lafanechere, A., Pene, F., Goulenok, C., et al. (2006) Changes in Aortic Blood Flow Induced by Passive Leg Raising Predict Fluid Responsiveness in Critically Ill Patients. Critical Care, 10, R132. http://dx.doi.org/10.1186/cc5044
[13]
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M.R. and Teboul, J.L. (2006) Passive Leg Raising Predicts Fluid Responsiveness in the Critically Ill. Critical Care Medicine, 34, 1402-1407. http://dx.doi.org/10.1097/01.CCM.0000215453.11735.06
[14]
Lamia, B., Ochagavia, A., Monnet, X., et al. (2007) Echocardiographic Prediction of Volume Responsiveness in Critically Ill Patients with Spontaneously Breathing Activity. Intensive Care Medicine, 33, 1125-1132. http://dx.doi.org/10.1007/s00134-007-0646-7
[15]
Maizel, J., Airapetian, N., Lorne, E., et al. (2007) Diagnosis of Central Hypovolemia by Using Passive Leg Raising. Intensive Care Medicine, 33, 1133-1138. http://dx.doi.org/10.1007/s00134-007-0642-y
[16]
Thiel, S., Kollef, M. and Isakow, W. (2009) Non-Invasive Stroke Volume Measurement and Passive Leg Raising Predict Volume Responsiveness in Medical ICU Patients: An Observational Cohort Study. Critical Care, 13, R111. http://dx.doi.org/10.1186/cc7955
[17]
Monnet, X., Osman, D., Ridel, C., et al. (2009) Predicting Volume Responsiveness by Using the End-Expiratory Occlusion in Mechanically Ventilated Intensive Care Unit Patients. Critical Care Medicine, 37, 951-956. http://dx.doi.org/10.1097/CCM.0b013e3181968fe1
[18]
Biais, M., Vidil, L., Sarrabay, P., et al. (2009) Changes in Stroke Volume Induced by Passive Leg Raising in Spontaneously Breathing Patients: Comparison between Echocardiography and Vigileo/FloTrac Device. Critical Care, 13, R195. http://dx.doi.org/10.1186/cc8195
[19]
Préau, S., Saulnier, F., Dewavrin, F., et al. (2010) Passive Leg Raising Is Predictive of Fluid Responsiveness in Spontaneously Breathing Patients with Severe Sepsis or Acute Pancreatitis. Critical Care Medicine, 38, 819-825. http://dx.doi.org/10.1097/CCM.0b013e3181c8fe7a
[20]
Guinot, P.G., Zogheib, E., Detave, M., et al. (2011) Passive Leg Raising Can Predict Fluid Responsiveness in Patients Placed on Venovenous Extracorporeal Membrane Oxygenation. Critical Care, 15, R216. http://dx.doi.org/10.1186/cc10451
[21]
Liu, Y., Lu, Y.H., Xie, J.F., Qiu, X.H., et al. (2011) Passive Leg Raising Predicts Volume Responsiveness in Patients with Septic Shock. Chinese Journal of Surgery, 49, 44-48.
[22]
Wang, H.L., Liu, H.T. and Yu, K.L. (2011) Clinical Observation of Passive Leg Raising Combined with Non Invasive Cardiac Output Monitoring System in Predicting Volume Responsiveness. Chinese Critical Care Medicine, 23, 146-149.
[23]
Monnet, X., Dres, M., Ferre, A., et al. (2012) Prediction of Fluid Responsiveness by a Continuous Non-Invasive Assessment of Arterial Pressure in Critically Ill Patients: Comparison with Four Other Dynamic Indices. British Journal of Anaesthesia, 109, 330-338. http://dx.doi.org/10.1093/bja/aes182
[24]
García, M.I.M., Cano, A.G., Romero, M.G., et al. (2012) Non-Invasive Assessment of Fluid Responsiveness by Changes in Partial End-Tidal CO2 Pressure during a Passive Leg-Raising Maneuver. Annals of Intensive Care, 2, 9. http://dx.doi.org/10.1186/2110-5820-2-9
[25]
Monnet, X., Bataille, A., Magalhaes, E., et al. (2013) End-Tidal Carbon Dioxide Is Better than Arterial Pressure for Predicting Volume Responsiveness by the Passive Leg Raising Test. Intensive Care Medicine, 39, 93-100. http://dx.doi.org/10.1007/s00134-012-2693-y
[26]
Vallee, F., Mari, A., Perner, A. and Vallet, B. (2010) Combined Analysis of Cardiac Output and CVP Changes Remains the Best Way to Titrate Fluid Administration in Shocked Patients. Intensive Care Medicine, 36, 912-914. http://dx.doi.org/10.1007/s00134-010-1831-7
[27]
Mandeville, J.C. and Colebourn, C.L. (2012) Can Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review. Critical Care Research and Practice, 2012, Article ID: 513480. http://dx.doi.org/10.1155/2012/513480
[28]
Jensen, M.B., Sloth, E., Larsen, K.M., et al. (2004) Transthoracic Echocardiography for Cardiopulmonary Monitoring in Intensive Care. European journal of Anaesthesiology, 21, 700-707. http://dx.doi.org/10.1097/00003643-200409000-00006
[29]
Irwig, L., Tosteson, A.N., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T.C., et al. (1994) Guidelines for Meta-Analyses Evaluating Diagnostic Tests. Annals of Internal Medicine, 120, 667-676. http://dx.doi.org/10.7326/0003-4819-120-8-199404150-00008
[30]
Khan, K.S., Dinnes, J. and Kleijnen, J. (2001) Systematic Reviews to Evaluate Diagnostic Tests. European Journal of Obstetrics & Gynecology and Reproductive Biology, 95, 6-11. http://dx.doi.org/10.1016/S0301-2115(00)00463-2
[31]
Riley, R.D. (2009) Multivariate Meta-Analysis: The Effect of Ignoring Within-Study Correlation. Journal of the Royal Statistical Society: Series A, 172, 789-811. http://dx.doi.org/10.1111/j.1467-985X.2008.00593.x