Cardiac Energetics in Presence of Lung Assist Devices: In Silico Study

DOI: 10.4236/mnsms.2016.63005, PP. 41-57

Keywords: Cardiovascular System, Numerical Model, Simulation, Mechanical Ventilation, Thoracic Artificial Lung, Ventricular Energetics

Full-Text   Cite this paper   Add to My Lib

Abstract:

The treatment with a mechanical ventilator is required whenever a patient’s respiratory system becomes unable to keep the concentrations of O2 and CO2 in blood at tolerable levels. However, in particular cases, the thoracic artificial lung (TAL) can be regarded as a viable alternative to mechanical ventilation (MV). We aim at studying the effects of mechanical ventilators and thoracic artificial lungs devices will have on the cardiovascular system. We will give careful consideration to cardiovascular energetic parameters, such as left and right ventricular external work, pressure-volume area, and cardiac mechanical efficiency. We simulated both, mechanically ventilated patients who are not subject to the application of an artificial lung and patients who are provided with a thoracic artificial lung (TAL). In the case of a thoracic artificial lung, we involved in our simulation studies all the usual operating modes of a TAL, viz. series mode, parallel mode, and hybrid mode of the TAL with regard to the native lung. In particular, the presented simulation results will contribute to elucidate the specific characteristics of each of the aforementioned operating modes. Generally, the energetic variables are influenced by different values of input TAL resistance in both modes: parallel and in series. In this paper, we concentrated on simulation studies of the effects evoked by TAL assistance on cardiac energetic and some other important circulatory parameters. The simulation results presented show that at all modes of TAL assistance exists a strong dependency on the TAL input variables and on the value of the mean intrathoracic pressure which has been assumed for a given situation.

References

[1]  Ochiai, Y., McCarthy, P.M., Smedira, N.G., Banbury, M.K., Navia, J.L., Feng, J., Hsu, A.P., Yeager, M.L., Buda, T., Hoercher, K.J., Howard, M.W., Takagaki, M., Doi, K. and Fukamachi, K. (2002) Predictors of Severe Right Ventricular Failure after Implantable Left Ventricular Assist Device Insertion: Analysis of 245 Patients. Circulation, 106, 198-202.
[2]  Mitchell, J.R., Sas, R., Zuege, D.J., Doig, C.J., Smith, E.R., Whitelaw, W.A., Tyberg, J.V. and Belenkie, I. (2005) Ventricular Interaction during Mechanical Ventilation in Closed-Chest Anesthetized Dogs. Canadian Journal of Cardiology, 21, 73-81.
[3]  Colquitt, R.B., Colquhoun, D.A. and Thiele, R.H. (2011) In Silico Modelling of Physiologic Systems. Best Practice & Research. Clinical Anaesthesiology, 25, 499-510.
http://dx.doi.org/10.1016/j.bpa.2011.08.006
[4]  De Lazzari, C., Mimmo, R., et al. (1991) CARDIOSIM© Cardiovascular Software Simulator Developed at the Institute of Clinical Physiology, Rome, Italy. C.N.R. National Research Council. https://cardiosim.dsb.cnr.it/
[5]  Ferrari, G., De Lazzari, C., Mimmo, R., Tosti, G. and Ambrosi, D. (1992) A Modular Numerical Model of the Cardiovascular System for Studying and Training in the Field of Cardiovascular Physiopathology. Journal of Biomedical Engineering, 14, 91-107.
http://dx.doi.org/10.1016/0141-5425(92)90014-C
[6]  De Lazzari, C., Genuini, I., Quatember, B. and Fedele, F. (2014) Mechanical Ventilation and Thoracic Artificial Lung Assistance during Mechanical Circulatory Support with PUCA Pump: In Silico Study. Computer Methods and Programs in Biomedicine, 113, 642-654.
http://dx.doi.org/10.1016/j.cmpb.2013.11.011
[7]  De Lazzari, C., Genuini, I., Pisanelli, D.M., D’Ambrosi, A. and Fedele, F. (2014) Interactive Simulator for e-Learning Environments: A Teaching Software for Health Care Professionals. BioMedical Engineering OnLine, 13, 172.
http://dx.doi.org/10.1186/1475-925X-13-172
[8]  Boschetti, F., Perlman, C.E., Cook, K.E. and Mockros, L.F. (2000) Hemodynamic Effects of Attachment Modes and Device Design a Thoracic Artificial Lung. ASAIO Journal, 46, 42-48.
http://dx.doi.org/10.1097/00002480-200001000-00013
[9]  Perlman, C.E. and Mockros, L.F. (2007) Hemodynamic Consequences of Thoracic Artificial Lung Attachment Configuration: A Computational Model. ASAIO Journal, 53, 50-64.
http://dx.doi.org/10.1097/01.mat.0000249867.39647.43
[10]  Kuo, A.S., Perlman, C.E., Mockros, L.F. and Cook, K.E. (2008) Pulmonic Valve Function during Thoracic Artificial Lung Attachment. ASAIO Journal, 54, 197-202.
http://dx.doi.org/10.1097/MAT.0b013e318164e485
[11]  Sagawa, K., Maughan, L., Suga, H. and Sunagawa, K. (1988) Cardiac Contraction and the Pressure-Volume Relationships. Oxford University Press, New York.
[12]  De Lazzari, C. (2012) Interaction between the Septum and the Left (Right) Ventricular Free Wall in Order to Evaluate the Effects on Coronary Blood Flow: Numerical Simulation. Computer Methods in Biomechanics and Biomedical Engineering, 15, 1359-1368.
http://dx.doi.org/10.1080/10255842.2011.597354
[13]  De Lazzari, C., Neglia, D., Ferrari, G., Bernini, F., Micalizzi, M., L’Abbate, A. and Trivella, M.G. (2009) Computer Simulation of Coronary Flow Waveforms during Caval Occlusion. Methods of Information in Medicine, 48, 113-122.
http://dx.doi.org/10.3414/me0539
[14]  Maughan, W.L., Sunagawa, K. and Sagawa, K. (1987) Ventricular Systolic Interdependence: Volume Elastance Model in Isolated Canine Hearts. American Journal of Physiology, 253, H1381-H1390.
[15]  De Lazzari, C., L’Abbate, A., Micalizzi, M., Trivella, M.G. and Neglia, D. (2014) Effects of Amlodipine and Adenosine on Coronary Haemodynamics: In Vivo Study and Numerical Simulation. Computer Methods in Biomechanics and Biomedical Engineering, 17, 1642-1652.
http://dx.doi.org/10.1080/10255842.2012.761691
[16]  Shi, Y., Lawford, P. and Hose, R. (2011) Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System. BioMedical Engineering OnLine, 10, 33.
http://dx.doi.org/10.1186/1475-925x-10-33
[17]  Marini, J.J., Culver, B.H. and Butler, L. (1981) Mechanical Effect of Lung Distension with Positive Pressure on Cardiac Function. The American Review of Respiratory Disease, 124, 382-386.
[18]  De Lazzari, C., Darowski, M., Ferrari, G., Clemente, F. and Guaragno, M. (2000) Computer Simulation of Haemodynamic Parameters Changes with Left Ventricle Assist Device and Mechanical Ventilation. Computers in Biology and Medicine, 30, 55-69.
http://dx.doi.org/10.1016/S0010-4825(99)00026-8
[19]  De Lazzari, C., Darowski, M., Ferrari, G., Pisanelli, D.M. and Tosti, G. (2006) Modelling in the Study of Interaction of Hemopump Device and Artificial Ventilation. Computers in Biology and Medicine, 36, 1235-1251.
http://dx.doi.org/10.1016/j.compbiomed.2005.08.001
[20]  De Lazzari, C., Darowski, M., Ferrari, G., Pisanelli, D.M. and Tosti, G. (2006) The Impact of Rotary Blood Pump in Conjunction with Mechanical Ventilation on Ventricular Energetic Parameters: Numerical Simulation. Methods of Information in Medicine, 45, 574-583.
[21]  De Lazzari, C., Darowski, M., Wolski, P., Ferrari, G., Tosti, G. and Pisanelli, D.M. (2005) In Vivo and Simulation Study of Artificial Ventilation Effects on Energetic Variables in Cardiosurgical Patients. Methods of Information in Medicine, 44, 98-105.
[22]  Duke, G.J. (1999) Cardiovascular Effects of Mechanical Ventilation. Critical Care & Resuscitation, 1, 388-399.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133