Finite Element Analysis (FEA) for the Beam-Column Joint Subjected to Cyclic Loading Was Performed Using ANSYS

DOI: 10.4236/cs.2016.78138, PP. 1581-1597

Keywords: Beam-Column Joints, Cyclic Load, Ferrocement, Ductility, Hysteresis Curve, ANSYS

Full-Text   Cite this paper   Add to My Lib

Abstract:

This paper analyses the seismic performance of exterior beam-column joints strengthened with unconventional reinforcement detailing. The beam-column joint specimens were tested with reverse cyclic loading applied at the beam end. The samples were divided into two groups based on the joint reinforcement detailing. The first group (Group A) of three non-ductility specimens had joint detailing in accordance with the construction code of practice in India IS456-2000, and the second group (Group B) of three ductility specimens had joint reinforcement detailed as per IS13920-1993, with similar axial load cases as the first group. The experimental studies are proven with the analytical studies carried out by finite element models using ANSYS. The results show that the hysteresis simulation is satisfactory for both un-strengthened and ferrocement strengthened specimens. Furthermore, when ferrocement strengthening is employed, the strengthened beam-column joints exhibit better structural performance than the un-strengthened specimens of about 31.56% and 38.98 for DD-T1 and DD-T2 respectively. The analytical shear strength predictions were in line with the test results reported in the literature, thus adding confidence to the validity of the proposed models.

References

[1]  Bindhu, K.R. and Jaya, K.P. (2012) Strength and Behavior of Exterior Beam Column Joints with Diagonal cross Bracing Bars. Asian Journal of Civil Engineering (Building and Housing), 11, 397-410.
[2]  Dogan, E. and Neven, K. (2003) Seismic Retrofit with Continuous Slurry Infiltrated Mat Concrete Jackets. ACI Structural Journal, 100, 713-722.
[3]  Maria, J.F. and Chris, G.K. (2014) Influence of Pinching Effect of Exterior Joints on the Seismic Behaviour of RC Frames. Earthquake and Structure, 6, 89-110.
http://dx.doi.org/10.12989/eas.2014.6.1.089
[4]  Matthew, J.F. and Halil, S. (2011) Behavior of Exterior Reinforced Concrete Beam-Column Joints Including a New Reinforcement. Structural Engineering and Mechanics, 40, 867-883.
http://dx.doi.org/10.12989/sem.2011.40.6.867
[5]  Ramakrishna, R.V.S. and Ravindra, V. (2012) Experimental Investigation on Rehabilitation of Reinforced Cement Concrete Interior Beam-Column Joints Using CFRP and GFRP Sheets. International Journal of Engineering Science and Technology, 4, 874-881.
[6]  Hamid, N.H., Hadi, N.D. and Ghani, K.D. (2013) Retrofitting of Beam-Column Joint Using CFRP and Steel Plate. International Journal of Civil, Architectural Science and Engineering, 7, 300-305.
[7]  Robert, R.S. and Arulraj, P.G. (2010) Experimental Investigation on Behavior of Reinforced Concrete Beam Column Joints Retrofitted with GFRP-AFRP Hybrid Wrapping. International Journal of Civil and Structural Engineering, 1, 245-253.
[8]  Umut, A. and Stefano, P. (2002) Assessment and Design Procedure for the Seismic Retrofit of Reinforced Concrete Beam-Column Joints Using FRP Composite B Structures Subjected to Seismic Forces. Journal of Composites for Construction, 16, 21-34.
[9]  Sushil, S., Urmil, V.D. and Himat, S. (2013) FRP Wrapping for RC Columns with Varying Corner Radii. Procedia Engineering, 51, 220-229.
http://dx.doi.org/10.1016/j.proeng.2013.01.031
[10]  Pradip, S., Rajesh, A. and Menon, D. (2007) Design of RC Beam Column Joints under Seismic Loading. Journal of Structural Engineering, 33, 449-457.
[11]  Senthilkumar, E., Murugesan, A. and Thirugnanam, G.S. (2010) Experimental Study on Behavior of Retrofitted with FRP Wrapped RC Beam-Column Exterior Joints Subjected to Cyclic Loading. International Journal of Civil and Structural Engineering, 1, 64-79.
[12]  Said, A.M., Nehdi, M.L. and Kehew, A.E. (2004) Use of FRP for RC Frame in Seismic Zones, Evaluation of FRP Beam Column Joints Rehabilitation Techniques. Applied Composite Materials, 11, 205-226.
http://dx.doi.org/10.1023/B:ACMA.0000035462.41572.7a
[13]  Jamal, S.M. and Nabeela, A. (2005) Lateral Load Response of High Performance Fibre Reinforced Concrete Beam Column Joints. Construction and Building Material, 19, 500-508.
http://dx.doi.org/10.1016/j.conbuildmat.2005.01.007
[14]  Shannag, M.J., Barakat, S. and Abdul-kareem, M. (2000) Cyclic Behavior of HPFRC Repaired Reinforced Concrete Interior Beam-Column Joints. Materials and Structures, 35, 348-356.
http://dx.doi.org/10.1007/BF02483154
[15]  IS13920-1993 (2002) Indian Standard Ductile Detailing of Reinforced Concrete Structures Subjected to Seismic Forces. Bureau of Indian Standards, New Delhi.
[16]  IS456-2000 (2000) Indian Standard Plain and Reinforced Concrete Code of Practice. Bureau of Indian Standards, New Delhi.