Detection  2016 

Studying Different Etching Methods Using CR-39 Nuclear Track Detector

DOI: 10.4236/detection.2016.43007, PP. 45-53

Keywords: Chemical Etching, Microwave, Ultrasound, CR-39, Track Etching Parameters

Full-Text   Cite this paper   Add to My Lib

Abstract:

In this research we try to investigate the optimum etching time for the tracks originate in (CR-39) solid state nuclear track detector after irradiated with alpha source (241Am) using three different etching techniques: the traditional method (water bath), microwaves and ultrasound devices. The track etching parameters: bulk etch rate (VB), track etch rate (VT), track etch rate ratio evaluates (V), critical angle (θC), and etching efficiency (η) were calculated in this research. It’s seen that the optimum etching time was ranging with (60 - 150 min), (20 - 30 min) and (60 - 120 min) when etching with water bath, microwave and ultrasound respectively. Also we observed that the critical angle was (24.29) when etching CR-39 detector with microwave. This value is lower than the critical angles values for the detector etched with water bath or ultrasound; thus it can be the optimum magnitude because its decrease leads to increasing the number of the tracks appeared in the detector and the etching efficiency.

References

[1]  Fleischer, R.L., Price, P.B. and Walker, R.M. (1965) Solid-State Track Detectors: Applications to Nuclear Science and Geophysics. Annual Review of Nuclear Science, 15, 1-28.
http://dx.doi.org/10.1146/annurev.ns.15.120165.000245
[2]  Tripathy, S.P., Kolekar, R.V., et al. (2010) Microwave-Induced Chemical Etching (MCE): A Fast Etching Technique for the Solid Polymeric Track Detectors (SPTD). Nuclear Instruments and Methods in Physics Research A, 612, 421- 426. http://dx.doi.org/10.1016/j.nima.2009.10.096
[3]  Dazhuang, Z. (2010) Methods Using CR-39 Plastic Nuclear Track Detectors in Radiation Research. Nova Science Publishers, Inc., New York, 10.
[4]  Durrani, S.A. and Bull, R.K. (1987) Solid-State Nuclear Detection; Principles, Methods, and Applications. Pergamon Press, UK.
[5]  Shahid, M. (2007) Improvements and Calibration of Nuclear Track Detectors of Rare Particle Searches and Fragmentation Studies. University degli Bologna, 12.
[6]  Nada, F. (2014) Evaluation of the Uranium Concentrations in Human Tissues Samples by Fission Fragments Induced Using CR-39 Nuclear Track Detector. IJAIEM, 3, 98-104.
[7]  Hassan, A.Y. (2015) Studying the Radioactivity in Two Human Organs Breast and Uterus Using CR-39 and Lexan Track Detectors. M.Sc. Thesis, University of Al-Mustansiriyah.
[8]  Pandey, A.K., Kalsi, P.C. and Iyer, R.H. (1998) Effects of High Intensity Ultrasound in Chemical Etching of Particle Tracks in Solid State Nuclear Track Detectors. Nuclear Instruments and Methods in Physics Research B, 143, 393-399. http://dx.doi.org/10.1016/S0168-583X(97)00735-0
[9]  Al-Niaemi, S.H.S. (2014) Effects of Ultrasound in Etching and Detecting Parameters of CR-39 Detector. Jordan Journal Physics, 7, 35-42.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133