Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zimmer Biomet, Warsaw, IN) for total hip arthroplasty. Between 2007 and 2013, the registry with 476 hip joints was reviewed retrospectively. There were 210 (48.4%) female and 224 (51.6%) male patients. The average age of the patients at the surgery was 63.9 (± 12.0) years and the average follow-up period was 2.6 years [0.5, 6.5]. At the final follow-up, there was no loosening or cup failure. There were 2 infections, 1 dislocation and 1 liner fracture, resulting in revision hip surgery. Average Harris hip score improved from 53.9 preoperatively to 91.4 postoperatively. The survivorship of Regenerex Ring Loc+ cup and the low complication rate is comparable with previous studies using other 3-D porous metal prostheses. Although this short-term outcome from the institute is very encouraging, a longer follow-up study is required.
References
[1]
Huo, M.H. (2002) What’s New in Hip Arthroplasty. Journal of Bone and Joint Surgery (American), 84, 1894-1905.
[2]
Della Valle, C.J., Mesko, N.W., Quigley, L., Rosenberg, A.G., Jacobs, J.J. and Galante, J.O. (2009) Primary Total Hip Arthroplasty with a Porous-Coated Acetabular Component. A Concise Follow-Up, at a Minimum of Twenty Years, of Previous Reports. Journal of Bone and Joint Surgery (American), 91, 1130-1135. http://dx.doi.org/10.2106/JBJS.H.00168
[3]
Engh, C.A., Hopper Jr., R.H. and Engh Jr., C.A. (2004) Long-Term Porous-Coated Cup Survivorship Using Spikes, Screws, and Press-Fitting for Initial Fixation. Journal of Arthroplasty, 19, 54-60. http://dx.doi.org/10.1016/j.arth.2004.06.004
[4]
Herberts, P., Ahnfelt, L., Malchau, H., Stromberg, C. and Andersson, G.B. (1989) Multicenter Clinical Trials and Their Value in Assessing Total Joint Arthroplasty. Clinical Orthopedics Related Research, 249, 48-55. http://dx.doi.org/10.1097/00003086-198912000-00007
[5]
Friedman, R.J., Black, J., Galante, J.O., Jacobs, J.J. and Skinner, H.B. (1994) Current Concepts in Orthopedic Biomaterials and Implant Fixation. Instructional Course Lecture, 43, 233-255.
[6]
Small, S.R., Berend, M.E., Howard, L.A., Rogge, R.D., Buckley, C.A. and Ritter, M.A. (2013) High Initial Stability in Porous Titanium Acetabular Cups: A Biomechanical Study. Journal of Arthroplasty, 28, 510-516. http://dx.doi.org/10.1016/j.arth.2012.07.035
[7]
Data on File at Zimmer Biomet, Inc.
[8]
Bonicoli, E., Piolanti, N., Andreani, L., Parchi, P. and Lisanti, M. (2013) Preliminary Report with the RegenerexTM Revision Shell: Clinical, Functional, and Radiographic Evaluation with a Mean Follow-Up of 25 Months. European Orthopedic Traumatology, 4, 9-14. http://dx.doi.org/10.1007/s12570-012-0146-2
[9]
Sillesen, N.H., Greene, M.E., Nebergall, A.K., Nielsen, P.T., Laursen, M.B., Troelsen, A. and Malchau, H. (2015) Three Year RSA Evaluation of Vitamin E Diffused Highly Crosslinked Polyethylene Liners and Cup Stability. Journal of Arthroplasty, 30, 1260-1264. http://dx.doi.org/10.1016/j.arth.2015.02.018
[10]
Gruen, T.A., Poggie, R.A., Lewallen, D.G., Hanssen, A.D., Lewis, R.J., O’Keefe, T.J., Stulberg, S.D. and Sutherland, C.J. (2005) Radiographic Evaluation of a Monoblock Acetabular Component: A Multicenter Study with 2- to 5-Year Results. Journal of Arthroplasty, 20, 369-378. http://dx.doi.org/10.1016/j.arth.2004.12.049
[11]
Macheras, G., Kateros, K., Kostakos, A., Koutsostathis, S., Danomaras, D. and Papagelopoulos, P.J. (2009) Eight- to Ten-Year Clinical and Radiographic Outcome of a Porous Tantalum Monoblock Acetabular Component. Journal of Arthroplasty, 24, 705-709. http://dx.doi.org/10.1016/j.arth.2008.06.020
[12]
Malizos, K.N., Bargiotas, K., Papatheodorou, L., Hantes, M. and Karachalios T. (2008) Survivorship of Monoblock Trabecular Metal Cups in Primary THA: Midterm Results. Clinical Orthopedics Related Research, 466, 159-166. http://dx.doi.org/10.1007/s11999-007-0008-3
[13]
Naziri, Q., Issa, K., Pivec, R., Harwin, S.F., Delanois, R.E. and Mont, M.A. (2013) Excellent Results of Primary THA Using a Highly Porous Titanium Cup. ORTHOPEDICS, 36, e390-e394. http://dx.doi.org/10.3928/01477447-20130327-10
[14]
Naudie, D.D.R., Somerville, L., Korczak, A., Yuan, X., McCalden, R.W., Holdsworth, D. and Bourne, R.B. (2013) A Randomized Trial Comparing Acetabular Component Fixation of Two Porous Ingrowth Surfaces Using RSA. Journal of Arthroplasty, 28, 28-52. http://dx.doi.org/10.1016/j.arth.2013.06.041
[15]
Kleinhans, J.A., Jakubowitz, E., Seeger, J.B., Heisel, C. and Kretzer, J.P. (2009) Macroscopic Third-Body Wear Caused by Porous Metal Surface Fragments in Total Hip Arthroplasty. ORTHOPEDICS, 32, 364. http://dx.doi.org/10.3928/01477447-20090501-06
[16]
Olof, S., Mats, S., Olle, M., Ake, J., Torbjorn, A. and Henrik, B. (2009) The Ring Loc Liner Compared with the Hexloc Liner in Total Hip Arthroplasty. Orthopedic Reviews, 1, e16.
[17]
Isaac, D.L., Forder, J., Skyrme, A.D. and James, S.E. (2007) The Biomet Bi-Metric Total Hip Arthroplasty and Universal Acetabular Cup: High Polyethylene Failure Rate in the Medium Term. Journal of Arthroplasty, 22, 697-700. http://dx.doi.org/10.1016/j.arth.2006.09.015