电子学报  2012 

电子胶囊中基于非对称结构的无源双向通信芯片设计

DOI: 10.3969/j.issn.0372-2112.2012.10.034, PP. 2107-2111

Keywords: 电子胶囊,人体通信,无线能量获取,无源双向通信

Full-Text   Cite this paper   Add to My Lib

Abstract:

将电子设备附着在医用胶囊外表面构成电子胶囊可以用来监测服药依从性,本文着重讨论了其中无源双向通信芯片的设计方法.综合考虑无线信号在人体内的传输损耗和电子胶囊中微型天线辐射效率等因素,本文在设计中创新地采用了下行/上行通信不同载波频率的非对称系统结构.在下行通信中采用了传输损耗较小的13.56MHz低频信号,实现对芯片的唤醒以及工作模式的配置;在上行通信中则采用了915MHz高频信号,以优化胶囊天线的辐射效率.系统采用标准的UMC130nmCMOS工艺实现,面积为1500×800μm2.实验结果表明,下行通信时该无源芯片的唤醒灵敏度为-4dBm,数据率为17kb/s;上行通信时芯片可以周期性的主动发射频率为915MHz的脉冲信号,数据率为0.75kb/s.

References

[1]  K C Farmer.Methods for measuring and monitoring medication regimen adherence in clinical trials and clinical practice [J].Clinical Therapeutics,1999,21(6):1074-1090.
[2]  K Finkenzeller.RFID Handbook:Fundamental and Applications in Contactless Smart Cards and Identification [M].2nd Ed,West Sussex,U K,2003.
[3]  We Liu,K Vichienchom.A neuro-stimulus chip with telemetry unit for retinal prosthetic device [J].IEEE Journal of Solid-State Circuits,2000,35(10):1487-1497.
[4]  K Najafi,H Yu.Low-power interface circuits for bio-implantable microsystems [A].IEEE International Solid-States Circuits Conference [C].USA:IEEE Press,2003.194-487.
[5]  M Oberle.Low power system-on-chip for biomedical application.ETH No.14509,IIS/ETH Zurich,2002.
[6]  H Yu.Electronic pills for medication compliance Monitoring.University of Florida,2010.
[7]  H Yu,R Bashirullah.A low power ASK clock and data recovery circuit for wireless implantable electronics.IEEE Custom Intergrated Circuits Conference.USA:IEEE Press,2006.249-253.
[8]  W S Bond,D A Hussar.Detection methods and strategies for improving medication compliance [J].American Journal of Hospital Pharmacy,1991,48(9):1978-1988.
[9]  H Yu,G Flores,S Reza,et al.Feasibility study of printed capsule antennas for medication compliance monitoring [A].Proceeding of Biomedical Circuits and Systems Conference [C].USA:IEEE Press,2007.41-44.
[10]  Nakamoto,et al.A passive UHF RF identification CMOS tag IC using ferroelectric RAM in 0.35-μm technology [J].IEEE Journal of Solid-State Circuits,2007,42(1):101-110.
[11]  K D Wise,D J Anderson,et al.Wire-less implantable microsystems:High-density electronic interfaces to the nervous system [J].IEEE Proceedings,2004,92(1):76-97.
[12]  T Akin,K Najafi,R M Bradley.A wireless implantable multi-channel digital neural recording system for a micromachined sieve electrode [J].IEEE Journal of Solid State circuits,1998,33(1):109-118.
[13]  D P Lindsey,E L McKee.A new technique for transmission of signals from implantable transducers [J].IEEE Transactions on Biomedical Engineering,1998,45(5):614-619.
[14]  M A Stuchly,S S Stuchly.Dielectric properties of biological substances-tabulated [J].Journal of Microwave Power,1980,15(1):19-26.
[15]  L C Chirwa.Electromagnetic radiation from ingested sources in the human intestine between 150MHz and 1.2GHz [J].IEEE Transactions on Biomedical Engineering,2003,50(4):484-492.
[16]  H Yu,G S Irby,D M Peterson,et al.A printed capsule antenna for medication compliance monitoring [J].IEE Electronics Letters,2007,43(22):1179-1181.
[17]  Y Li,et al.A low power column-level high speed auto-zeroed comparator for CMOS active pixel sensor based vertex detector [J].Chinese Journal of Electronics,2010,19(1):53-56.