全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
地球学报  2010 

钼同位素的MC-ICP-MS测定方法研究

DOI: 10.3975/cagsb.2010.02.16

Keywords: 多接收器等离子体质谱,钼同位素,谱峰干扰,基体效应

Full-Text   Cite this paper   Add to My Lib

Abstract:

本文报道了运用多接收器等离子体质谱进行Mo同位素组成测定的方法,测定过程中的仪器质量歧视校正采用样品-标样交叉法。实验对Mo同位素测定过程中的谱峰干扰、基体效应、浓度效应、酸度效应和重现性等问题进行了详细研究。结果表明Zr的存在对Mo同位素测定不会产生影响;Sr不适合作为Mo同位素测定的元素内标;当m(Ag)/m(Mo)≤1时,Ag的存在不会对Mo同位素测定产生影响;当样品相对于标样的Mo浓度变化不大于50%时,Mo同位素分析不受浓度影响;以HNO3为进样介质时,HNO3的浓度(0.1mol/L~0.2mol/L)对Mo同位素分析没有影响。CAGS-Mo相对于Alfa-Mo的δ100/95Mo、δ98/95Mo和δ97/95Mo分别为-0.34‰±0.10‰(2sd)、-0.22‰±0.05‰(2sd)和-0.13‰±0.08‰(2sd),在95%的置信区间内,该方法的外部精度不大于0.06‰/amu。

References

[1]  何学贤;朱祥坤;杨淳;唐索寒.多接收器等离子体质谱(MC-ICP-MS)Pb同位素高精度研究[J].地球学报,2005(z1)
[2]  ARNOLD G L;ANBAR A D;BARLING J;LYONS T W Molybdenum isotope evidence for widespread anoxia in mid-Proterozoic oceans [J] 2004(5667) doi:10.1126/science.1091785
[3]  ANBAR A D;ROUXEL O,Metal stable isotopes in paleoceanography.Annu Rev Earth Plane Murthy V R,1962.Isotopic anomalies of Molybdenum in some iorn meteorites,Journal of Geophysical Research,2007.
[4]  ANBAR A D;DUAN Y;LYON T W;SCOTT C,GARVIN J,BUICK R,A Whiff of Oxygen before the Great Oxidation Event,Science,2007.
[5]  周炼;周红兵;李茉;王峰.扬子克拉通古大陆边缘Mo同位素特征及对有机埋藏量的指示意义[J].地球科学-中国地质大学学报,2007(6)
[6]  张羽旭;温汉捷;樊海峰.地质样品中Mo同位素测定的前处理方法研究[J].分析化学,2009(2)
[7]  谢烈文;杨进辉;杨岳衡;吴福元.MC-ICP-MS高精度测定Pb同位素比值[J].地球学报,2005(z1)
[8]  李世珍;朱祥坤;唐索寒;何学贤,蔡俊军.多接收器等离子体质谱法Zn同位素比值的高精度测定[J].岩石矿物学杂志,2008(4)
[9]  李津;朱祥坤;唐索寒,酸度对多接收器等离子体质谱法Cu、Zn同位素测定的影响,分析化学,2008.
[10]  蒋少涌;凌洪飞;赵葵东;朱茂炎 杨竞红 陈永权,华南寒武纪早期牛蹄塘组黑色页岩系中Ni-Mo多金属硫化物矿层的Mo同位素组成讨论,岩石矿物学杂志,2008.
[11]  ZHU Xiang-kun;LI Zhi-hong;ZHAO Xin-miao;TANG Suo-han HE Xue-xian Belshaw N S,High-precision measurements of Fe isotopes using MC-ICP-MS and Fe isotope compositions of geological reference materials,Acta Petrologica et Mineralogica,2008.
[12]  ZHU Xiang-kun;MAKISHIMA A;GUO Y;BELSHAW N S,O\'NIONS R K,High precision measurement of titanimn isotope ratios by plasma source mass spectrometry,Intenational Journal of Mass Spectrometry,2002.
[13]  ZHOU Lian;ZHOU Hong-bing;LI Mo;WANG Feng,Molybdenum Isotope Signatures from Yangtze Craton Continental Margin and Its Indication to Organic Burial Rate,Earth Sciences,2007.
[14]  ZHANG Yu-xu;WEN Han-jie;FAN Hai-Feng,Chemical pretreatment methods for measurement of Mo isotope ratio on geological samples,Chinese Journal of Analytical Chemistry,2009.
[15]  XIE Liewen;YANG Jinhui;YANG Yueheng;WU Fuyuan.High-Precision Analysis of Pb Isotope Ratios Using MC-ICP-MS[J].Acta Geoscientica Sinica,2005(z1)
[16]  SIEBERT C;NAGLER T F;KRAMERS J D,Determination of molybdenum isotope fractionation by double-spike multicollector inductively coupled plasma mass speotrometry,Geochemistry Geophysics and Geosystems,2001.
[17]  PIETRUSZKA A J;REZNIK A D,Identification of a matrix effect in the MC-ICP-MS due to sample purification using ionexchange resin:An isotopic case study of molybdenum,International Journal of Mass Spectrometry and Ion Processes,2008.
[18]  PIETRUSZKA A J;WALKER R J;CANDELA P A,Deterwmination of mass-dependent molybdenum isotopic variations by MC-ICP-MS:An evaluation of matrix effects,Chemical Geology,2006.
[19]  PEARCE C R;COHEN A S;COE A L;BURTON K W,Molybdenum isotope evidence for global ocean anoxia coupled with perturbations to the carbon cycle during the Early Jurassic,Geology,2008.
[20]  NAKAGAWA Y;FIRDAUS M L;NORISUYE K;SOHRIN Y IRISAWA K HIRATA T,Precise Isotopic Analysis ofMo in Seawater Using Multiple Collector-Inductively CoupledMass Spectrometry Coupled with a Chelating Resin Column Preconcentration Method,Analytical Chemistry,2008.
[21]  朱祥坤;李志红;赵新苗;唐索寒 何学贤 Belshaw N S.铁同位素的MC-ICP-MS测定方法与地质标准物质的铁同位素组成[J].岩石矿物学杂志,2008(4)
[22]  蔡俊军;朱祥坤;唐索寒;李世珍 何学贤.多接收电感耦合等离子体质谱Cu同位素测定中的干扰评估[J].高校地质学报,2006(3)
[23]  Wille, M ;Kramers, JD ;Nagler, TF ;Beukes, NJ ;Schroder, S ;Meisel, T ;Lacassie, JP ;Voegelin, AR,Evidence for a gradual rise of oxygen between 2.6 and 2.5 Ga from Mo isotopes and Re-PGE signatures in shales,Geochimica et Cosmochimica Acta?,2007, 71(10).
[24]  WIESER M E;DE LAETER J R,A preliminary study of isotope fractionation in molybdenites,International Journal of Mass Spectrometry and Ion Processes,2003.
[25]  WIESER M E;DE LAETER J R,Thermal ionization mass spectrometry of molybdenum isotopes,International Journal of Mass Spectrometry and Ion Processes,2000.
[26]  SIEBERT C;N(A)GLER T F;VON BLANCKENBURG F;KRAMERS J D,Molybdenum isotope records as a potential new proxy for paleoceanograpby,Earth and Planetary Science Letters,2003.
[27]  MALINOVSKY D;RODUSHKIN I;BAXTER D C;INGRI J (O)HLANDER B,Molybdenum isotope ratio measurements on geological samples by MC-ICPMS,International Journal of Mass Spectrometry and Ion Processes,2005.
[28]  JIANG Shao-yong;LIN Hong-fei;ZHAO Kui-dong;ZHU Mao-yan YANG Jin-hong CHEN Yong-quan.A discussion on Mo isotopic compositions of black shale and Ni-Mo sulfide bed in the early Cambrian Niutitang Formation in south China[J].Acta Petrologica et Mineralogica,2008(4)
[29]  MURTHY V R,Elemental and isotopic abundances of molybdenum in some meteorites,Geochimica et Cosmochimica Acta,1963.
[30]  MURTHY V R,Isotopic anomalies of Molybdenum in some iorn meteorites,Journal of Geophysical Research,1962.
[31]  MCMANUS J;N(A)GLER T F;SIEBERT C;WHEAT C G HAMMOND D E,Oceanic molybdenum isotope fractionation:Diagenesis and hydrothermal ridge-flank alteration,Geochemistry Geophysics and Geosystems,2002.
[32]  Chloe Nadia Marechal ;Philippe Telouk ;Francis Albarede,Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry,Chemical geology?,1999, 156(1-4).
[33]  MALINOVSKY D;RODUSHKIN I;OHLANDER B Determination of the isotopic composition of molybdenum in the bottom sediments of freshwater basins [J] 2007(4)
[34]  何学贤;朱祥坤;杨淳;唐索寒.多接收等离子质谱(MC-ICP-MS)测定Mg同位素初步研究[J].地球学报,2005(z1)
[35]  LI Shi-Zhen;ZHU Xiang-kun;TANG Suo-han;HE Xue-xian CAI Jun-jun,The application of MC-ICP-MS to high-precision measurement of Zn isotope ratios,Acta Petrologica et Mineralogica,2008.
[36]  LI Jin;ZHU Xiang-kun;TANG Suo-han,The effects of acidities on Cu and Zn isotope measurements by MC-ICP-MS,Chinese Journal of Analytical Chemistry,2008.
[37]  Bernd Lehmann ;Thomas F. Nagler ;Heinrich D. Holland ;Martin Wille ;Jingwen Mao ;Jiayong Pan ;Dongsheng Ma ;Peter Dulski,Highly metalliferous carbonaceous shale and Early Cambrian seawater,Geology?,2007, 35(5).
[38]  JOHNSON C M;BEARD B L,Correction of instrumentally produced mass fractionation during isotopic analysis of Fe by thermal ionization mass spectrometry,International Journal of Mass Spectrometry and Ion Processes,1999.
[39]  HE Xue-xian;ZHU Xiang-kun;YANG Chun;TANG Suo-han.High-precision Analysis of Pb Isotope Ratios Using MC-ICP-MS[J].Acta Geoscientica Sinica,2005(z1)
[40]  HE Xue-xian;ZHU Xiang-kun;YANG Chun;TANG Suo-han.Primary Study on High-precision Measurement of Magnesium Isotopes Using MC-ICP-MS[J].Acta Geoscientica Sinica,2005(z1)
[41]  Stephen J. G. Galer,Optimal double and triple spiking for high precision lead isotopic measurement,Chemical geology?,1999, 157(3-4).
[42]  CAI Jun-Jun;ZHU Xiang-Kun;TANG Suo-han;LI Shi-zhen HE Xue-xian,Assessment of interferences in Cu isotope ratio measurements using Multiple-collector Inductively Coupled Plasma Source Mass Spectrometry,Geological Journal of China Universities,2006.
[43]  J. Barling ;G. L. Arnold ;A. D. Anbar,Natural mass-dependent variations in the isotopic composition of molybdenum,Earth and Planetary Science Letters?,2001, 193(3-4).
[44]  ANBAR A D,Molybdenum stable isotopes:Observations,interpretations and directions,Reviews in Mineralogy and Geochemistry,2004.
[45]  ANBAR A D;KNAB K A;BARLING J,Precise Determina tion of Mass-Dependent Variations in the Isotopic Composi tion of Molybdenum Using MC-ICP-MS,Analytical Chemistry,2001.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133