张建中, 龚延风. 空气源热泵冷热水机组在南京的应?用[J]?.现代空调,2001, 3 (3):141-156. ?ZHANG Jianzhong, GONG Yanfeng. Application of air to water heat pump in Nanjing[J].Modern Air Conditioning, 2001, 3 (3):141-156.?
KRAKOW K I,LIN Sui,YAN Li. An idealized model of reversed-cycle hot gas defrosting[J]. ASHRAE Trans,1993,99(2):317-328. ?
[4]
黄虎,李志浩,虞维平. 风冷热泵冷热水机组除霜过程仿真[J]. 东南大学学报,2001,31(1):52-56. ?HUANG Hu, LI Zhihao, YU Weiping. Dynamic simulation of air cooled heat pump/chiller under defrosting ?condition[J]?. Journal of Southeast Universty, 2001, 31(1):52-56.?
[5]
刘川,郭宪民,杨宾. 使用条缝翅片管换热器的空气源热泵机组除霜特性研究[J]. 流体机械,2009,37(12): 52-56. ?LIU Chuan, GUO Xianmin, YANG Bin. Experimental ?study? on the defrost characteristics of an air source heat pump ?unit? with split fin-tube heat exchanger[J]. Fluid Machinery, 2009,37(12):52-56.?
[6]
O’NEAL D L, PETERSON K T. Effect of short-tube orifice size on the performance of an air source heat pump during the reverse-cycle defrosting[J].International Journal of ?Refrigeration,?1991,14(1):52-57. ?
[7]
HUANG Dong,LI Quanxu,YUAN Xiuling. Comparison between hot-gas bypass defrosting and reverse-cycle defrosting methods on an air-to-water heat pump[J]. Applied Energy,2009,86(9):1697-1703. ?
[8]
黄东,袁秀玲,陈蕴光. 节流机构对风冷热泵冷热水机组逆循环除霜时间的影响[J]. 西安交通大学学报,2003,37(5):512-518. ?HUANG Dong, YUAN Xiuling, CHEN Yunguang. Effect of expansion device on the reverse-cycle defrost time of an air-source heat pump chiller[J]. Journal of Xian Jiaotong University,2003,37(5):512-518. ?
[9]
DING Yanjun,MA Gguoyuan,CHAI Qinhu,et al. Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator[J]. International Journal of Refrigeration, 2004,27(6): 671-678.?
[10]
黄东,袁秀玲,张波.风机提前启动对风冷热泵冷热水机组除霜的影响[J].西安交通大学学报,2004,38(5):448-451. ?HUANG Dong, YUAN Xiuling, ZHANG Bo, et al. Effect of air cooled coil fan pre-start on the refrigeration system dynamics during the reverse-cycle defrost of an air source heat pump chiller[J]. Journal of Xi′an Jiaotong University, 2004, 38 (5): 448-451.?
[11]
KRAKOW K I, YAN Li, LIN Sui. A model of hot-gas defrosting of evaporators(PartⅠ):heat and mass transfer theory[J]. ASHRAE Trans,1992, 98(1): 451-474. ?
[12]
HOFFENBECKER N,KLEIN S A, REINDL D T. Hot gas defrost model development and validation[J].International Journal of Refrigeration,2005,28(4):605-615.?
[13]
李九如,韩志涛,姚杨,等. 基于实验参数的空气源热泵除霜滞留表面水蒸发模型[J]. 上海交通大学学报, 2008,42(6): 989-992. ?LI Jiuru, HAN Zhitao, YAO Yang,et al. Surface water vaporization model of air source heat pump defrosting based on experimental parameters[J]. Journal of Shanghai Jiaotong University,2008,42(6):989-992.
[14]
韩志涛,姚杨,马最良,等. 空气源热泵蓄能热气除霜新系统与实验研究[J]. 哈尔滨工业大学学报,2007,39(6):901-903. ?HAN Zhitao, YAO Yang, MA Zuiliang,et al. A new air source heat pump system of energy store for heat flux defrost and its experimental study[J]. Journal of Harbin Institute of Technology, 2007,39(6):901-903.?