管间距对水平管降膜蒸发流动形态和传热的影响

DOI: 10.3969/j.issn.1006-7043.201309007

Keywords: 管间距, 传热系数, 流动形态, 水平管降膜蒸发, 喷淋密度, 管周角度

Full-Text   Cite this paper   Add to My Lib

Abstract:

为了探讨管间距对水平管降膜蒸发的影响,以水为工质,研究了19 mm直径的铝黄铜水平管上降膜蒸发的传热与流动状况。通过对3种管间距在Re 范围35~347下液膜流动形态的观测,归纳出水平管降膜流动流态转变时的临界Re数;测量了管壁表面温度和饱和蒸汽温度,计算得到管子表面的平均传热系数和局部传热系数,分析了管间距对局部和平均传热系数的影响。实验结果表明:在较大管间距情况下,不同流态间转变的临界Re数没有明显区别,但是在小管间距情况下,滴柱状向柱状以及柱状向柱帘状转变的Re数会变小;平均传热系数会随着管间距变小而降低,且当管间距为0.3倍管径时,喷淋密度的变化对平均传热系数的影响将变得不明显。此外,沿管周方向顶部的局部传热系数也随管间距变小而明显下降。

References

[1]  KHAWAJI A D, KUTUBKHANAH I K. Advances in seawater desalination technologies [J]. Desalination, 2008, 221: 47-69.
[2]  YUNG D, LORENZ J J, GANIC E N. Vapor/liquid interaction and entrapment in failing film evaporators [J]. Journal of Heat Transfer, 1980, 101(1): 20-25.
[3]  RIBATSKI G, JACOBI M A. Falling-film evaporation on horizontal tubes-a critical review[J]. International Journal of Refrigeration, 2005, 28: 635-653.
[4]  GANIC N E, ROPPO N M. An experimental study of falling liquid film breakdown on a horizontal cylinder during heat transfer [J]. Journal of Heat Transfer, 1980, 102: 342-346.
[5]  MITROVIC J. Influence of tube spacing and flow rate on heat transfer from a horizontal tube to a falling liquid film[C]//Proceedings of the Eighth International Heat Trans. San Francisco,USA, 1996: 1949-1956.
[6]  HU X, JACOBI A M. The intertube falling film Part 1. Flow characteristics, mode transitions, and hysteresis [J]. Journal of Heat Transfer, 1996, 118: 616-6525.
[7]  ROQUES F J, DUPONT V, THOME R J. Falling film transitions on plain and enhanced tubes [J]. Journal of Heat Transfer, 2002, 124(3): 491-499.
[8]  PARKEN H W, FLETCHER S L. Heat transfer through falling film evaporation and boiling on horizontal tubes [J]. Journal of Heat Transfer, 1990, 112: 744-750.
[9]  MU X S, YANG Y, SHEN S Q, et al. Experimental study of heat transfer characteristics for horizontal tube falling film evaporation[C]//Proceedings of the ASME 2012 Summer Heat Transfer. Rio Grande, Puerto Rico, 2012.
[10]  MU X S, SHEN S Q, YANG Y, et al. Experimental study of falling film evaporation heat transfer coefficient on horizontal tube[J]. Desalination and Water Treatment, 2012, 5: 310-316.
[11]  牟兴森,杨勇,沈胜强.海水淡化中降膜蒸发过程的实验研究[J].热科学与技术, 2011, 10(4): 291-296.MU Xingsen, YANG Yong, SHEN Shengqiang. Experimental research of horizontal tube falling film evaporation in desalination[J]. Journal of Thermal Science and Technology, 2011, 10(4): 291-296.
[12]  HU X, JACOBI A M. The intertube falling film. Part 2 Mode effects on sensible heat transfer to a falling liquid film [J]. Journal of Heat Transfer, 1996, 118: 626-633.

Full-Text