用近红外光谱对组织氧测量方法的研究

Keywords: 近红外光谱多层生物组织氧无损监测技术饱和度Lambert-Beer定律集成光学器件人体组织学

Full-Text   Cite this paper   Add to My Lib

Abstract:

在多层生物组织模型下,提出了一种利用近红外光谱技术定量无损检测组织氧饱和度的方法,讨论了受试者具有不同的外层组织时,如何采用适当的校准方法使半定量测量组织血氧浓度变化值具有可靠性和可比性;自行设计的监测系统,结构较为简洁,其探头包括光源和2个检测器,光源采用双波长LED,检测器为集成光学器件,2个检测器分别放置在与光源不同距离的位置上;以240mmHg压力进行人体前臂组断,氧合血红蛋白HbO2、还原血红蛋白Hb的浓度变化和组织氧饱和度tSO2的测试结果与时间分辨光谱TRS方法所得结果一致;系统基线平稳,具有较好的稳定性和检测精度。

References

[1]  Jbsis F F. Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science, 1977, 198(4323): 1264-1267
[2]  COPE M, DEPLY D T. System for long term measurement of cerebral blood and tissue oxygenation on infants by near infrared transillumination. Phys. Med. Biol., 1988, 33: 1433-1442
[3]  Wickramasinghe Y, Liver L N, Spencer S A, et al. Plethysmographic validation of near spectroscopy monitoring of cerebral blood volumm. Arch.Dis.Child., 1992, 76: 407-411
[4]  Shiga T, Tanabe K, Nakase Y, et al. Development of a portable tissue oximeter using near infrared spectroscopy. Medical & Biological Engineering & Computing, 1995, 33: 622-626
[5]  Susumu Suzuki, Sumio Takasaki, Takeo Ozaki, et al. A tissue oxygenation monitor using NIR spatially resolved spectroscopy. SPIE, 1999, 3597: 582-592
[6]  Lehr H-P, Wickramasinghe Y. New prototype NIRS to investigate multi-regional cerebral blood and tissue oxygenation and haemodynamics. Medical & Biological Engineering & Computing, 2000, 38: 281-286
[7]  Feng S, Zeng F. Monte Carlo simulation of photon migration path distributions in multiple scattering media. SPIE, 1993, 1888: 78-89
[8]  Luo Q, Nioka S, Chancce B. Functional near-infrared imager. SPIE, 1997, 2979: 84-93
[9]  Delpy T, Cope M, P Van der Zee, et al. Estimation of optical pathlength through tissue from direct time of flight measurement.Phys. Med. Biol, 1988, 32(12): 1433-1442
[10]  Arlene Duncan, Meek Judith H, Matthew Clemence, et al. Optical pathlength measurements on adult head, calf and forearm and head of newborn infant using resolved optical spectroscopy. Phys. Med. Biol, 1995, 40: 295-304
[11]  WANG Feng, DING Hai-Shu, LIN Fang, et al. Accuracy analysis of the tissue oximeter using simulation. Optoelectronics Laser.(王峰,丁海曙,林方,等.组织氧检测精度的仿真分析.光电子.激光), 2000, 11(4): 422-426
[12]  Wang Feng, Ding Haishu, Tian Fenghua, et al. Influence of overlying tissue and probe geometry on the sensitivity of a near-infrared tissue oximeter. Physiological Measurement, 2001, 22: 201-208
[13]  Masatsugu Niwayama,Lin L, Shao J, et al. Quantitative measurement of muscle oxygenation by NIRS: Analysis of the influence of subcutaneous fat layer and skin. SPIE, 1999, 3597: 291-299
[14]  Masatsugu Niwayama, Takafumi Hamoka, Ling Lin, et al. Quantitative muscle oxygeantion measurement using NIRS with correction for influence of a fat layer: comparison of oxygen consumption rates with measurements by other technique. SPIE, 2000, 3911: 256-265

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133