核技术  2013 

基于MCNP5与WINXCOM仿真计算的铋玻璃屏蔽特性研究

DOI: DOI:10.11889/j.0253-3219.2013.hjs.36.110201, PP. 110201-110201

Keywords: 屏蔽材料,蒙特卡罗(MonteCarlo,MCNP),铋玻璃

Full-Text   Cite this paper   Add to My Lib

Abstract:

通过MCNP5(蒙特卡罗,MonteCarlo)和WINXCOM程序研究了在0.662MeV、1.17MeV和1.33MeV三种γ射线下铋玻璃的衰减系数,并与铅玻璃进行对比。根据衰减倍数K以及综合考虑材料屏蔽性能和机械性能后,材料可以选择含氧化铋含量为50%的铋玻璃。计算了137Cs与60Co源照射以及铋玻璃的厚度分别为2cm和10cm的水模体剂量率分布。结果反应出在适合的能量下,铋玻璃可能会替代铅玻璃作为防辐射玻璃。

References

[1]  Isaac CPJ, Sivakumar A, Kumar CRP. Lead levels in breast milk, blood plasma and intelligence quotient: A health hazard for women and infants [J]. Bulletin of Environmental Contamination and Toxicology. 2012, 88(2): 145-149
[2]  Pavlenko VI, Onishchuk VI, Pavlenko ZV, Orekhov KA. Effect of radiation on glasses in borosilicate and boron-lead-silicate systems [J]. Glass and Ceramics (English translation of Steklo i Keramika). 2002, 59(1-2): 11-13
[3]  Abt K. Lead-free inorganic and organic patterns for ceramics and glass
[4]  Bleifreie Anorganische und Organische Dekore fur Keramik und Glas Setzen sich Durch! [J]. Keramische Zeitschrift. 2006, 58(6): 416-418
[5]  Yue K, Luo WY, Dong XQ, Wang CS, Wu GH, Jiang MW, Zha YZ. A new lead-free radiation shielding material for radiotherapy [J]. Radiation Protection Dosimetry. 2009, 133(4): 256-260
[6]  Sun H-F, Li Y-H, Ji Y-F, Yang L-S, Wang W-Y, Li H-R. Environmental contamination and health hazard of lead and cadmium around Chatian mercury mining deposit in western Hunan Province, China [J]. Transactions of Nonferrous Metals Society of China (English Edition). 2010, 20(2): 308-314
[7]  Araujo A, Pereira C, Veloso MAF, Costa AL, Dalle HM. Flux and Dose Rate Evaluation of Iter System Using MCNP5 [J]. Braz J Phys. 2010, 40(1): 58-62
[8]  Isaac CPJ, Sivakumar A, Kumar CRP. Lead levels in breast milk, blood plasma and intelligence quotient: A health hazard for women and infants [J]. Bulletin of Environmental Contamination and Toxicology. 2012, 88(2): 145-149
[9]  Akkurt H. Benchmark results for Monte Carlo computations of decay time measurements [J]. Transactions of the American Nuclear Society. 2004, 91(2 ):117-118
[10]  Goncalves IF, Salgado J, Falcao A, Margaca FMA, Carvalho FG. MCNP simulation to optimise in-pile and shielding parts of the Portuguese SANS instrument [J]. Radiation Protection Dosimetry. 2005, 116(1-4): 562-565
[11]  Yue K, Luo WY, Dong XQ, Wang CS, Wu GH, Jiang MW, Zha YZ. A new lead-free radiation shielding material for radiotherapy [J]. Radiation Protection Dosimetry. 2009, 133(4): 256-260
[12]  Gallardo S, Rodenas J, Verdu G, Villaescusa JI. Analysis of shielding materials in a Compton spectrometer applied to X-ray tube quality control using Monte Carlo simulation [J]. Radiation Protection Dosimetry. 2005, 115(1-4): 375-379
[13]  El-Khayatt AM. NXcom - A program for calculating attenuation coefficients of fast neutrons and gamma-rays [J]. Annals of Nuclear Energy. 2011, 38(1): 128-132
[14]  Araujo A, Pereira C, Veloso MAF, Costa AL, Dalle HM. Flux and Dose Rate Evaluation of Iter System Using MCNP5 [J]. Braz J Phys. 2010, 40(1): 58-62
[15]  Akkurt H. Benchmark results for Monte Carlo computations of decay time measurements [J]. Transactions of the American Nuclear Society. 2004, 91(2 ):117-118
[16]  Goncalves IF, Salgado J, Falcao A, Margaca FMA, Carvalho FG. MCNP simulation to optimise in-pile and shielding parts of the Portuguese SANS instrument [J]. Radiation Protection Dosimetry. 2005, 116(1-4): 562-565
[17]  Gallardo S, Rodenas J, Verdu G, Villaescusa JI. Analysis of shielding materials in a Compton spectrometer applied to X-ray tube quality control using Monte Carlo simulation [J]. Radiation Protection Dosimetry. 2005, 115(1-4): 375-379
[18]  El-Khayatt AM. NXcom - A program for calculating attenuation coefficients of fast neutrons and gamma-rays [J]. Annals of Nuclear Energy. 2011, 38(1): 128-132

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133