1 Simionovici A, Chukalina M, Günzler F, et al. X-ray microtome by fluorescence tomography[J]. Nuclear Instruments and Methods in Physics Research Section A, 2001, 467(2): 889-892.
[2]
2 Boisseau P. Determination of three dimensional trace element distributions by the use of monochromatic x-ray microbeams[D]. Massachusetts Institute of Technology, Department of Physics, 1986.
[3]
3 DeJonge M D, Holzner C, Baines S B, et al. Quantitative 3D elemental microtomography of Cyclotella meneghiniana at 400-nm resolution[J]. Proceedings of the National Academy of Sciences, 2010, 107(36): 15676-15680.
[4]
4 Takeda T, Wu J, Huo Q, et al. X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice[J]. Journal of synchrotron radiation, 2008, 16(1): 57-62.
[5]
5 Kim S A, Punshon T, Lanzirotti A, et al. Localization of iron in Arabidopsis seed requires the vacuolar membrane transporter VIT1[J]. Science, 2006, 314(5803): 1295-1298.
[6]
6 Shepp L A, Vardi Y. Maximum likelihood reconstruction for emission tomography[J]. Medical Imaging, IEEE Transactions on, 1982, 1(2): 113-122.
[7]
7 Hudson H M, Larkin R S. Accelerated image reconstruction using ordered subsets of projection data[J]. Medical Imaging, IEEE Transactions on, 1994, 13(4): 601-609.
[8]
8 Yang Q, Deng B, Du G, et al. X‐ray fluorescence computed tomography with absorption correction for biomedical samples[J]. X‐Ray Spectrometry, 2014, 43(5): 278-285.
[9]
9 Yang Q, Deng B, Lv W, et al. Fast and accurate X-ray fluorescence computed tomography imaging with the ordered-subsets expectation maximization algorithm[J]. Journal of synchrotron radiation, 2012, 19(2): 210-215.
[10]
10 Zhao X, Hu J, Yang T, et al. An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT[J]. Insight-Non-Destructive Testing and Condition Monitoring, 2013, 55(5): 237-242.
[11]
11 Hsiao T, Rangarajan A, Khurd P, et al. An accelerated convergent ordered subsets algorithm for emission tomography[J]. Physics in medicine and biology, 2004, 49(11): 2145-2156.
[12]
12 刘力, 吴朝霞. 具有超松弛因子的 OSEM 重建算法[J]. 中国图象图形学报: A 辑, 2002, 7(8): 814-817.
[13]
Liu Li, Wu Zhaoxia. OSEM Reconstruction with Overrelaxation[J]. Journal of Image and Graphics: A, 2002, 7(8): 814-817.
[14]
13 杨群. 快速低剂量 X 射线荧光 CT 及其生物医学应用研究[D]. 北京:中国科学院,,2012.
[15]
Yang Qun. Fast, Low Dose X-ray Fluorescence CT for the Biomedical Applications[D]. Beijing: Chinese Academy of Sciences, 2012.
[16]
14 Hudson H, Larkin R. "Accelerated image reconstruction using ordered subsets of projection data." Medical Imaging, IEEE Transactions on, 2002, 13(4): 601-609.
[17]
15 Biao D, Qun Y, Hong-Lan X, et al. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline[J]. Chinese Physics C, 2011, 35(4): 402-404.