应力对混凝土中氯离子渗透性的影响

, PP. 1102-1106

Keywords: 道路工程,氯离子渗透性,电导率法,扩散系数

Full-Text   Cite this paper   Add to My Lib

Abstract:

采用电导率法测试C30和C60混凝土中氯离子的扩散系数,并参照CCES01-2004标准对氯离子的渗透性进行评价,结果表明:在应力作用下,氯离子在C30混凝土中的渗透性比在C60混凝土中弱;氯离子在拉应力作用下的渗透性比在压应力作用下强;在压应力作用下,氯离子渗透扩散系数随着应力比的增加先减后增,压应力比为0.35时,氯离子渗透性最小;在拉应力下,氯离子渗透扩散系数随着应力比的增加持续上升,当应力比到达0.35时,扩散系数急剧增大。综合考虑下,混凝土在应力比为0.35时,氯离子的渗透性最低,对混凝土耐久性影响最小。

References

[1]  Banthia N,Bhargava A. Permeability of stressed concrete and role of fiber reinforcement[J]. ACI Mater,2007,104(1):70-76.
[2]  Saito M,Ishimori H. Chloride permeability of concrete under static and repeated compressive loadings[J]. Cement and Concrete Research,1995,25(4):803-808.
[3]  方永浩,李志清,张亦涛. 持续压荷载作用下混凝土的渗透性[J]. 硅酸盐学报,2005,33(10):1281-1286. Fang Yong-hao,Li Zhi-qing,Zhang Yi-tao. Permeability of concrete under continuous stress[J].Journal of Silicate,2005,33(10):1281-1286.
[4]  Banthia N,Biparva A,Mindess S. Permeability of concrete under stress[J]. Cement Concrete Research,2005,35(9):1651-1655.
[5]  Wang K,Jansen D C,Shah S P,et al. Permeability study of cracked concrete[J]. Cement and Concrete Research,1997,27(3):381-393.
[6]  Omkar Deo,Milani S,Narayanan N. Permeability reduction in pervious concretes due to clogging:experiments and modeling[J]. Journal of Materials in Civil Engineering,2010,22(7):741-751.
[7]  Hutchinson Tara C,Soppe Travis E. Experimentally measured permeability of uncracked and cracked concrete components[J]. Journal of Materials in Civil Engineering,2012,24(5):548-559.
[8]  Vardanega P J. State of the art:permeability of asphalt concrete[J]. Journal of Materials in Civil Engineering,2014,26(1):54-64.
[9]  Das B B,Singh D N,Pandey S P. Rapid chloride ion permeability of opc- and ppc-based carbonated concrete[J]. Journal of Materials in Civil Engineering,2012,24(5) :606-611.
[10]  Khoe Chandra, Sen Rajan, Bhethanabotla Venkat R. Oxygen permeability of frp-concrete repair systems[J]. Journal of Composites for Construction,2012,16(3):277-285.
[11]  Tian Zheng-hong,Qiao Pi-zhong. Multiscale performance characterization of concrete formed by controlled permeability formwork liner[J]. Journal of Aerospace Engineering,2013,26(4):684-697.
[12]  Wang H L,Xu W Y. Permeability evolution laws and equations during the course of deformation and failure of brittle rock[J]. Journal of Engineering Mechanics,2013,139(11):1621-1626.
[13]  Assaad Joseph J,Harb Jacques. Use of the falling-head method to assess permeability of freshly mixed cementitious-based materials[J]. Journal of Materials in Civil Engineering,2013,25(5):580-588.
[14]  Jones Christopher A,Grasley Zachary C. Correlation of radial flow-through and hollow cylinder dynamic pressurization test for measuring permeability[J]. Journal of Materials in Civil Engineering,2009,21(10):594-600.
[15]  Khan M I. Permeation of high performance concrete[J]. Journal of Materials in Civil Engineering,2003,15(1):84-92.
[16]  Masad Eyad,Birgisson Bjorn,Al-Omari Aslam,et al. Analytical derivation of permeability and numerical simulation of fluid flow in hot-mix asphalt[J]. Journal of Materials in Civil Engineering,2004,16(5):487-496.

Full-Text