去甲肾上腺素聚合膜固定葡萄糖氧化酶用于葡萄糖传感

, PP. 372-376

Keywords: 去甲肾上腺素,葡萄糖氧化酶,聚合,传感

Full-Text   Cite this paper   Add to My Lib

Abstract:

研究了中性缓冲溶液中葡萄糖氧化酶在去甲肾上腺素循环伏安电氧化聚合膜中的共沉积.考察了共沉积时去甲肾上腺素和葡萄糖氧化酶浓度的影响,结果表明5.5mmol/L去甲肾上腺素(NA)和4.0mg/mL葡萄糖氧化酶(GOD)时所制葡萄糖传感器性能最佳.也考察了检测电位、溶液pH及电活性物质干扰等因素.当溶液pH值为7.0,检测电位为0.7V时,传感器响应电流与葡萄糖浓度在0.059.1mmol/L之间呈现良好的线性关系,检测下限为2μmol/L(S/N=3),且传感器的响应时间短(15s内)、抗干扰能力强、稳定性好.测得固定酶的米氏常数(Kappm)为11.3mmol/L.

References

[1]  Kukla A L, Pavluchenko A S, Shirshov Y M, et al. Application of sensor arrays based on thin films of conducting polymers for chemical recognition of volatile organic solvents[J]. Sens Actuat B:Chem,2009,135(2):541-551.
[2]  Pan D W, Chen J H, Yao S Z, et al. Amperometric glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film at copper-modified gold electrode[J]. Sens Actuat B:Chem,2005,104(1):68-74.
[3]  Sun Z, Tachikawa H. Enzyme-based bilayer conducting polymer electrodes consisting of polymetallophthalocyanines and polypyrrole-glucose oxidase thin films[J]. Anal Chem,1992,64(10):1112-1117.
[4]  Miao Y, Chen J, Wu X. Using electropolymerized non-conducting polymers to develop enzyme amperometric biosensors[J]. Trends Biotechnol,2004,22(5):227-231.
[5]  Pan D, Chen J, Nie L, et al. Amperometric glucose biosensor based on immobilization of glucose oxidase in electropolymerized o-aminophenol film at Prussian blue-modified platinum electrode[J]. Electrochimica Acta,2004,49(5):795-801.
[6]  Jin G, Peng X, Ding Y. The electrochemical modification of clenbuterol for biosensors of dopamine, norepinephrine, adrenalin, ascorbic acid and uric acid at paraffin-impregnated graphite electrode[J]. Biosens Bioelectro,2008,24(4):1031-1035.
[7]  Zhou H, Chen H, Luo S, et al. Preparation and bioelectrochemical responses of the poly(m-phenylenediamine) glucose oxidase electrode[J]. Sens Actuat B:Chem,2004,101(1/2):224-230.
[8]  Sulak M T, Gkdoan , Gülce H. Amperometric glucose biosensor based on gold-deposited polyvinylferrocene film on Pt electrode[J]. Biosens Bioelectron,2006,21(9):1719-1726.
[9]  Jiang X, Lin X. Overoxidized polypyrrole film directed DNA immobilization for construction of electrochemical micro-biosensors and simultaneous determination of serotonin and dopamine[J]. Anal Chim Acta,2005,537(1/2):145-151.
[10]  Garjonyte R, Malinauskas A. Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer[J]. Sens Actuat B:Chem,1999,56(1/2):85-92.
[11]  Andrade J M, Peres R C D, Oestreicher E G, et al. Immobilization of d-hydantoinase in polyaniline[J]. J Mol Catal B:Enzym,2008,55(3/4):185-188.
[12]  Dong H, Wang S, Liu A, et al. Drug effects on the electrochemical detection of norepinephrine with carbon fiber and diamond microelectrodes[J]. J Electroanal Chem,2009,632(1/2):20-29.
[13]  Yang H, Chung T, Kim Y, et al. Glucose sensor using a microfabricated electrode and electropolymerized bilayer films[J]. Biosens Bioelectron,2002,17(3):251-259.
[14]  Vidal J C, Méndez S, Castillo J R. Electropolymerization of pyrrole and phenylenediamine over an organic conducting salt based amperometric sensor of increased selectivity for glucose determination[J]. Anal Chim Acta,1999,385(1-3):203-211.