制冷剂流动方向对微通道蒸发器房间空调器性能影响的对比试验研究

, PP. 21-24

Keywords: 制冷剂流动方向,微通道蒸发器,房间空调器,环境温度,红外成像

Full-Text   Cite this paper   Add to My Lib

Abstract:

试验研究UF(UpwardFlow,制冷剂在微通道蒸发器中自下而上流动)和DF(DownwardFlow,制冷剂在微通道蒸发器中自上而下流动)2种制冷剂流动方式下微通道房间空调器的制冷性能,并对其名义制冷工况下制冷剂配液分布进行红外成像.试验结果表明,随着室内空气干球温度的上升,2种方式的制冷量和能效比均不断上升;名义制冷工况下,UF方式优于DF方式,前者的制冷量和能效比EER比后者分别高出21.52%和14.94%;红外成像分析表明,UF方式分液效果优于DF方式.但是,UF方式蒸发器尾部制冷剂分配较少,换热效果下降.

References

[1]  Qi Zhaogang,Zhao Yu,Chen Jiangping. Performance enhancement study of mobile air conditioning system using microchannel heat exchangers[J]. International Journal of Refrigeration,2010,33(2):301-312.
[2]  Spokoyny M,Trofimov V,Qiu X L,et al. Compact heat sink with combined structures of dimples-protrusions with pin-fins or microchannels:review,simulation and experimental data[C]// Proceedings of the ASME International Heat Transfer Conference. Washington DC,2010:481-493.
[3]  Han Yanhui,Liu Yan,Li Ming,et al. A review of development of micro-channel heat exchanger applied in air-conditioning system[J]. Energy Procedia,2012(14):148-153.
[4]  刘巍,朱春玲. 分流板开孔面积对微通道换热器流量分配的影响[J]. 流体机械,2014,42(1):6-10.
[5]  Liu Wei,Zhu Chunling. Flow distribution characteristics of deflector with different opening area[J]. Fluid Machinery,2014,42(1):6-10.(in Chinese)
[6]  刘巍,朱春玲. 分流板结构对微通道平行流蒸发器性能的影响[J]. 化工学报,2012,63(3):761-766.
[7]  Liu Wei,Zhu Chunling. Effects of deflector structure on performance of micro-channel evaporator with parallel flow[J]. CIESC Journal,2012,63(3):761-766.(in Chinese)
[8]  殷辉,刘斌,申志远. 微通道蒸发器在不同R404A充注量下的运行特性[J]. 低温工程,2013,193(3):58-62.
[9]  Yin Hui,Liu Bin,Shen Zhiyuan. Performance characteritics of microchannel evaporator with different R404A charge quantities[J]. Cryogenics,2013,193(3):58-62.(in Chinese)
[10]  张忠斌,杜凯,黄虎,等. 制冷剂充注量对微通道蒸发器房间空调器性能影响的试验研究[J]. 东南大学学报:自然科学版,2014,44(3):1-6.
[11]  Zhang Zhongbin,Du Kai,Huang Hu,et al. Experimental study on the impact of refrigerant charge on room air conditioner performance equipped with micro-channel evaporator[J]. Journal of Southeast University:Natural Science Edition,2014,44(3):1-6.(in Chinese)
[12]  Huang H,Li Q,Yuan D,et al. An experimental study on variable air volume operation of ducted air-conditioning with digital scroll compressor and conventional scroll compressor[J]. Applied Thermal Engineering,2008,28(7):761-766.