迁移性阻锈剂对氯盐污染混凝土耐久性的影响——电化学性能与渗透浓度前锋线(英文)

Full-Text   Cite this paper   Add to My Lib

Abstract:

钢筋锈蚀是混凝土结构提前破坏的主要原因,为提高氯盐环境下混凝土结构耐久性并延长其使用寿命,人们采取了包括掺入外加剂、应用高性能混凝土和环氧涂敷钢筋在内的很多方法,这些方法中迁移性阻锈剂(migratoryofcorrosioninhibitors,MCIs)在作为混凝土添加剂、表面涂敷和结构修补的应用中表现出很大的灵活性。研究了表面涂敷氨基醇和羧酸胺基迁移性阻锈剂(400g/m2)对掺加胶材总量0.5%氯化钠的C30混凝土中钢筋锈蚀的抑制效果及其在混凝土中的迁移性能,监测了涂敷MCIs前后混凝土试件中钢筋的电化学阻抗谱、开路电位、线性极化电阻和腐蚀电流。结果表明涂敷迁移性阻锈剂60d后钢筋混凝土试件平均腐蚀电流从涂敷前3.77μA/cm2降低为0.104μA/cm2,尤其是涂敷#6阻锈剂腐蚀电流最低可降低到涂敷前的1.1%;渗透浓度前锋线的分析结果表明在保护层下30~40mm处仍能检测到较高含量的有机氮,表明迁移性阻锈剂确实通过毛细孔和微细裂缝渗透进入了混凝土内部和钢筋表面,即使在氯盐条件下钢筋产生了锈蚀,在硬化混凝土表面涂敷迁移性阻锈剂也能有效抑制钢筋锈蚀发展或使其修复。

References

[1]  BATIS G,PANTAZOPOULOU P,ROUTOULAS A.Corrosion protec-tion investigation of reinforcement by inorganic coating in the presence of alkanolamine-based inhibitor[J].Cem Concr Com,2003,25(3):371–377. [2]DHOUIBI L,TRIKI E,RAHARINAIVO A.The application of elec-trochemical impedance spectroscopy to determine the long-term effec-tiveness of corrosion inhibitors for steel in concrete[J].Cem Concr Com,2002,24(1):35–43. [3]TRE’PANIER S M,HOPE B B,HANSSON C M.Corrosion inhibitors in concrete part III effect on time to chloride-induced corrosion initia-tion and subsequent corrosion rates of steel in mortar[J].Cem Concr Res,2001,31(5):713–718. [4]JAMIL H E,SHRIRI A,BOULIF R.Corrosion behaviour of reinforc-ing steel exposed to an amino alcohol based corrosion inhibitor[J].Cem Concr Com,2005,27(6):671–678. [5]MECHMECHE L B,DHOUIBI L,OUEZDOU M B,et al.Investiga-tion of the early effectiveness of an amino-alcohol based corrosion in-hibitor using simulated pore solutions and mortar specimens[J].Cem Concr Com,2008,30(3):167–173. [6]MORRIS W,VA′ZQUEZ M.A migrating corrosion inhibitor evaluated in concrete containing various contents of admixed chlorides[J].Cem Concr Res,2002,32(2):259–267. [7]SOYLEV T A,RICHARDON M G.Corrosion inhibitors for steel in concrete:state-of-the-art report[J].Constr Build Mater,2008,22(4):609–622. [8]GLASS G K,BUENFELD N R.The presentation of the chloride threshold level for corrosion of steel in concrete[J].Corros Sci,1997,39(5):1001–1013. [9]LIU Zhiyong,MIAO Changwen,LIU Jiaping,et al.Effectiveness of migratory corrosion inhibitors in simulated pore water of chlo-ride–contaminated concrete by means of electrochemical techniques[A]//SUN Wei,BREUGEL K,MIAO Changwen,et al,eds.Proceed-ings of the1st International Conference on Microstructure Related Durability of Cementitious Composites[C].RILEM Publications S.A.R.L.2008:1367–13754. [10]EYDEMANT A,OSTROVSKI A B,DEMIDOV A M.Analysis of diffusion rate of migrating corrosion inhibitor MCI2000in concrete using radioactive isotope tagging techniques[R].Insititetu of Con-struction Materials and Kurchatov Institute of Nuclear physics.Mos-cow,Rusia,1993:20. [11]ZHAO Xi,ZHANG Xiaodong,ZHOU Qin.Study on the penetrating depth of MCI in concrete by XPS[J].Chin Conc Cem Prod(in Chi-nese),2004,138(4):5–7. [12]HOLLOWAY L,NAIRN K,FORSYTH M.Concentration monitoring and performance of a migratory corrosion inhibitor in steel-reinforced concrete[J].Cem Concr Res,2004,34(10):1435–1440. [13]LIU Zhiyong,MIAO Changwen,ZHOU Weilin.Maintenance and improvement of durability of reinforced concrete using migrating corrosion Inhibitors[J].J Chin Ceram Soc(in Chinese),2008,36(10):1494–1500. [14]GB7173–87.Determination of Kjeldahl Nitrogen in soil[S](in Chi-nese).Beijing:China Standard Press,1987. [15]JAMIL H E,SHRIRI A,BOULIF R C,et al.Electrochemical behav-iour of amino alcohol-based inhibitors used to control corrosion of reinforcing steel[J].Electrochim Acta,2004,49(17–18):2753–2760. [16]BROOMFIELD J P,RODRIGUEZ J,ORTEGA L M,et al.Corrosion rate measurements in reinforced concrete structures by a linear polari-sation device[J].ACI Mater J,1994,SP151:215–232.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133