海底隧道混凝土结构耐久性监测

Full-Text   Cite this paper   Add to My Lib

Abstract:

胶州湾海底隧道是我国自行设计建造的第二条海底隧道,其设计服役寿命为100年。选择阳极梯监测地下水和盐雾中氯离子在混凝土中渗透过程,选择环形电极监测混凝土中水分迁移。通过传感器数据分析,获得海底隧道混凝土结构的耐久性能。阳极梯预埋在隧道海域段Ⅵ级岩石破碎带的喷射混凝土和衬砌混凝土中,以及隧道出入口。环形电极采用后装法安装在海域段最深处Ⅵ级围岩区和隧道出入口的衬砌混凝土中。通过安装初期和运行1年后的耐久性监测数据分析表明,传感器工作良好,且隧道混凝土结构耐久性能良好。

References

[1]  References:
[2]  ? QIU X B, LI S C, CHEN W Z. Numerical analysis of rock cover thickness of subsea tunnel [J]. Tunnel Undergr Space Technol, 2004(19): 426.
[3]  ? ZHAO Tiejun, JIN Zuquan, WANG Ming-ping. Environmental Condition and Durability of Lining Concrete in Qingdao Jiaozhou Bay Subsea Tunnel [J]. Chin J Rock Mech Eng, 2007, 26(2007–S2): 3823–3829.
[4]  ? SUN Jun. Discussion on some key technical issues for design and construction of undersea tunnels [J]. Chin J Rock Mech Eng, 2006, 25(8): 1513–1521.
[5]  ? EDVARDSEN C K, KIM Y J, PARK S J. Busan-geoje fixed link concrete durability design for the bridges and tunnels [J]. Tunnel Undergr Space Technol, 2006, 21(3/4): 432.
[6]  ? JIN Zuquan, SUN Wei, HOU Baorong, et al. Key coefficient of constructed lining concrete in Jiaozhou bay subsea tunnel [J]. J Central South Univ: Sci Technol, 2011, 42(3): 810–816.
[7]  ? QU Liqing, JIN Zuquan, ZHAO Tiejun, et al. Study on durablity parameter design of subsea tunnel reinforced concrete based on chloride corrosion [J]. Chin J Rock Mech Eng, 2007, 26(11): 2333–2340.
[8]  ? CHEN Zhaoyuan. Durability design of concrete structures [J]. Architecture Technol, 2003, 34(6): 451?454.
[9]  ? YANG Linde, GAO Zhanxue. The durability for concrete lining structure of highway-tunnel and the thickness of concrete cover [J]. China Civil Eng J, 2003, 36(12): 64?67.
[10]  ? KHATRI R P, SIRIVIVATANON V. Characteristic service life for concrete exposed to marine environments [J]. Cem Concr Res, 2004, 34(5): 745?752.
[11]  ? VEERACHAI Leelalerkiet, JE-WOON Kyung, MASAYASU Ohtsu. Analysis of half-cellpotential measurement for corrosion of reinforced concrete [J]. Construct Build Mater, 2004, 18(3): 155–162.
[12]  ? LAW D W, CAIRNS J, MILLARD S G, et al. Measurement of loss of steel from reinforcing bars in concrete using linear polarisation resistance measurements [J]. NDT & E Int, 2004, 37(5): 381–388.
[13]  ? FAN hong, FU Yandi, ZHAO Tiejun. Research on carbonation and chloride profiles of concrete after 21 years of exposure [J]. Ind Construct, 2011, 41(5): 14–18.
[14]  ? BATIS G, ROUTOULAS Th. Steel rebars corrosion investigation with strain gages [J]. Cem Concr Compos, 1999(21): 163–171.
[15]  ? GRAHAM Miller, PATRICK Gaydecki, SUNG Quek, et al. A combined Q and heterodyne sensor incorporating real-time DSP for reinforcement imaging, corrosion detection and material characterisation [J]. Sens Actuators A: Phys, 2005(121): 339–346.
[16]  ? SHAMSAD Ahmad. Reinforcement corrosion in concrete structures, its monitoring and service life prediction-a review [J]. Cem Concr Compos, 2003(25): 459–471.
[17]  ? GUSTAVO S Duffó, SILVIA B. Farina. Development of an embeddable sensor to monitor the corrosion process of new and existing reinforced concrete structures [J]. Construct Build Mater, 2009(23): 2746–2751.
[18]  ? LEGAT A. Monitoring of steel corrosion in concrete by electrode arrays and electrical resistance probes [J]. Electrochim Acta, 2007(52): 7590–7598.
[19]  ? RAUPACH M, SCHIEBL P. Macrocell sensor systems for monitoring of the corrosion risk of the reinforcement in concrete structures [J]. NDT & E Int, 2001(34): 435–442.?

Full-Text