用颗粒计数和浊度联合评价颗粒物去除作用

Keywords: 颗粒计数,浊度,过滤,预氧化,高锰酸盐复合剂

Full-Text   Cite this paper   Add to My Lib

Abstract:

采用浊度检测和颗粒计数技术评价了高锰酸盐复合剂预氧化工艺对滤后水中颗粒物的去除效果。结果表明,PPC预氧化能有效地强化滤后水中颗粒物去除效果,使颗粒总数降低幅度达65.0%,采用浊度指标不能有效地反映滤后水质的变化,将浊度检测与颗粒计数技术相结合,能更有效地反映滤池对颗粒物质的去除效果。

References

[1]  杨艳玲,李星,丛丽.等.优化监测与净水工艺提高致病原生动物去除率[J].给水排水,2003,29(6):22-26.YANG Yan-ling,LI Xing,CONG Li,et al.Optimizing of water quality monitoring and removal of pathogenic protozoa in waterworks[J].Water & Wsatewater Engineering,2003,29(6):22-26.(in Chinese)
[2]  EDZWALD J K,OBIASON JOHN E T,et al.Giardia and cryptosporidium removals by clarification and filtration under challenge conditions[J].J AWWA,2000,92(12):70-84.
[3]  许国仁,马军,陈忠林.等.高锰酸钾复合药剂助凝生产性试验[J].给水排水,1995,21(9):8-13.XU Guo-ren,MA Jun,CHEN Zhong-lin,et al.Full scale experiments of potassium permanganate composite as coagulation aid[J].Water & Wastewater Engineering,,1995,21(9):8-13.(in Chinese)
[4]  陈杰,李星,杨艳玲.等.预氯胺化控制消毒副产物技术研究[J].中国给水排水,2005,21(7):5-8.CHEN Jie,LI Xing,YANG Yan-ling,et al.Study on pre-chloramination process for control disinfection byproducy[J].Chi- na water & wastewater,2005,21(7):5-8.(in Chinese)
[5]  李星,杨艳玲,张岩,等.高锰酸钾安全强化预氯化工艺消毒效能的研究[J].工业水处理,2005,25(9):23-26.LI Xing,YANG Yan-ling,ZHANG Yan,et al.Study of inactivation efficacy of pre-chlorination process safely enhanced by potassium permanganate[J].Industrial Water Treatment,2005,25(9):23-26.(in Chinese)
[6]  陈忠林,杨艳玲,余敏,等.高锰酸盐复合药剂处理臭味污染水源水的试验研究[J].哈尔滨建筑大学学报,1999,32 (6):78-81.CHEN Zhong-lin,YANG Yan-ling,YU Min,et al.Laboratory test for treatment of odor polluted source water by perman- ganate composite chemicals[J].Journal of Harbin University of Civil Engineering and Architecture,1999,32(6):78-81. (in Chinese)
[7]  ROSE J B.Occurrence and significance of cryptosporidium in water[J].J AWWA,1998,80(2):53-58.
[8]  DUGAN N R,FOX K R,OWENS J H,et al.Controlling cryptosporidium oocysts using conventional treatment[J].J AWWA,2001,93(12):12-25.
[9]  李星,杨艳玲.用新型透光式颗粒检测法测定颗粒凝聚程度[J].北京工业大学学报,2003,29(3):301-304.LI Xing,YANG Yan-ling.Determination of particle aggregation degree with new light extinction particle monitoring tech- nique[J].Journal of Beijing University of Technology,2003,29(3):301-304.(in Chinese)

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133