通信基站用整体式空气-空气热虹吸管换热机组的实验研究

Keywords: 热虹吸管,空气-空气换热器,节能,通信基站

Full-Text   Cite this paper   Add to My Lib

Abstract:

为了降低通信基站空调的耗电量,提出利用热虹吸管换热机组辅助空调为基站降温的节能方案,研制出空气-空气热虹吸管换热机组样机,并对样机进行了实验测试.结果表明,在实验工况范围内,换热机组运行稳定、可靠,换热效果良好,温度效率η可达50%,能效比EER可达10.9。

References

[1]  TU Rang,LIU Xiao-hua,LI Zhen,et al.Energyperformance analysis on telecommunication base station[J].Energy and Buildings,2011,43:315-325.
[2]  迟洋,强应海,夏春.温控节能在通信基站中的应用[J].电信工程技术与标准化,2010(6):83-87.CHI Yang,QIANG Ying-hai,XIA Chun.Temperaturecontrol energy saving application in the communicationbase station[J].Telecom Engineering Technics andStandardization,2010(6):83-87.(in Chinese)
[3]  郑大永.移动基站:绿色进行时[J].中国电信业,2009(8):68-70.ZHENG Da-yong.Mobile base station:green times[J].China Telecommunications Trade,2009(8):68-70.(inChinese)
[4]  CHOI J,JEON J,KIM Y.Cooling performance of ahybrid refrigeration system designed for telecommunicationequipment rooms[J].Applied Thermal Engineering,2007,27(11/12):2026-2032.
[5]  DAN N,MATTI K.Application of CFD technique inthermal design of a telecommunication base station[C]∥9th International Flotherm User Conference,Orlando,October 16-19,2000.
[6]  陈沂,吴基,王飞,等.广州地区通信基站通风冷却节能技术研究[J].建筑科学,2008,24(12):27-31.CHEN Yi,WU Ji,WANG Fei,et al.Study on ventilationcooling technology for telecommunication base stations inGuangzhou[J].Building Science,2008,34(12):27-31.(in Chinese)
[7]  鲍玲玲.通信基站用空气换热器的研究[D].邯郸:河北工程大学城市建设学院,2008.BAO Ling-ling.Study on air heat exchanger incommunication base station[D].Handan:College ofUrban Construction,Hebei University of Engineering,2008.(in Chinese)
[8]  江亿,郑川,杨文俊,等.热管技术在移动通信基站环境控制中的应用及节能研究[J].广东科技,2010(17):98.JIANG Yi,ZHENG Chuan,YANG Wen-jun,et al.Heatpipe application for environmental control intelecommunication base station and energy-saving research[J].Guangdong Science&Technology,2010(17):98.(in Chinese)
[9]  庄骏.热管与热管换热器[M].上海:上海交通大学出版社,1989:2.
[10]  FEHRM M,REINERS W,UNGEMACH M.Exhaust airheat recovery in buildings[J].International Journal ofRefrigeration,2002,25(4):439-449.
[11]  周峰,马国远.热虹吸管能量回收设备夏季工作特性的实验研究[J].暖通空调,2007,37(12):58-62.ZHOU Feng,MA Guo-yuan.Experiment ofcharacteristics of thermosiphon heat recovery equipmentunder summer condition[J].Heating Ventilating&AirConditioning,2007,37(12):58-62.(in Chinese)
[12]  李鹏.台隆科技:智能热管助力基站平均节能50%[J].通信世界,2010,29:40.LI Peng.Tailong technology:intelligent heat pipe helpsbase staion save 50%energy[J].Communications WorldWeekly,2010,29:40.(in Chinese)
[13]  田昕,周峰,马国远.通信基站环境控制能耗及其影响因素的模拟分析[C]∥2009中国制冷学会学术年会,天津,2009-11-01—03.TIAN Xin,ZHOU Feng,MA Guo-yuan.Simulation studyon using ambient energy to cool telecommunication basestation[C]∥2009 Chinese Association of RefrigerationAcademic Annual,Tianjin,November 1-3,2009.(inChinese)