苏继锋. 配电网中性点接地方式研究[J]. 电力系统保护与控制,2013,41(8):141-148. SU Jifeng. Research of neutral grounding modes in power distribution network[J]. Power System Protection and Control, 2013, 41(8): 141-148.
[2]
Kingrey L J, Painter R D, Locker A S. Applying high-resistance neutral grounding in medium-voltage systems[J]. IEEE Transactions on Industry Applications, 2011, 47(3): 1220-1231.
[3]
吕 军,陈维江,齐 波,等. 10 kV配电网经高阻接地方式下过电压及接地故障选线[J]. 高电压技术,2009,35(11):2728-2734. LÜ Jun, CHEN Weijiang, QI Bo, et al . Overvoltage and feeder detection for earth fault under high-resistance grounding mode in 10 kV distribution networks[J]. High Voltage Engineering, 2009, 35(11): 2728-2734.
[4]
刘学忠,王贤宗,Li Yishan,等. 风电场电缆集电网操作过电压的模拟试验和暂态分析[J]. 高电压技术,2014,40 (1):61-66. LIU Xuezhong, WANG Xianzong, Li Yishan, et al . Simulating experiment and transient analysis on switching surges in cable collection grid of wind power plant[J]. High Voltage Engineering, 2014, 40 (1): 61-66.
[5]
耿建昭,王 宾,董新洲,等. 中性点有效接地配电网高阻接地故障特征分析及检测[J]. 电力系统自动化,2013,37(16):85-91. GENG Jianzhao, WANG Bin, DONG Xinzhou, et al . Analysis and detection of high impedance grounding fualt in neutral point effectively grounding distribution network[J]. Automation of Electric Power Systems, 2013, 37(16): 85-91.
[6]
曾祥君,胡京莹,王媛媛,等. 基于柔性接地技术的配电网三相不平衡过电压抑制方法[J]. 中国电机工程学报,2014,34(4):678-684. ZENG Xiangjun, HU Jingying, WANG Yuanyuan, et al . Suppressing method of three-phase unbalanced overvoltage based on distribution networks flexible grounding control[J]. Proceedings of the CSEE, 2014, 34(4): 678-684.
[7]
刘 鹏,郭倩雯,杨 铭,等. 抗直流偏磁的变压器中性点接地方式探讨[J]. 高电压技术,2015,41(3):794-799. LIU Peng, GUO Qianwen, YANG Ming, et al . Discussion about neutral point connection mode of transformer to inhibit DC bias[J]. High Voltage Engineering, 2015, 41(3): 794-799.
[8]
代 姚,孙才新,袁 涛,等. 采用过电压波形识别的单相接地暂态过电压抑制方法[J]. 高电压技术,2010,36(5):1136-1142. DAI Yao, SUN Caixin, YUAN Tao, et al . Suppression method of single-phase grounding transient over-voltage using recognition of over-voltage waveform[J]. High Voltage Engineering, 2010, 36(5): 1136-1142.
[9]
黄艳玲,司马文霞,杨 庆,等. 电力系统实测过电压信号的特征量提取与验证[J]. 高电压技术,2013,39(1):60-66. HUANG Yanling, SIMA Wenxia, YANG Qing, et al. Features extraction and validation from measured overvoltage signals of power system[J]. High Voltage Engineering, 2013, 39(1): 60-66.
[10]
吴 靓,张英杰,徐 高,等. 基于原子分解的谐振接地系统自适应故障选线方法[J]. 高电压技术,2014,40(11):3554-3562. WU Liang, ZHANG Yingjie, XU Gao, et al . Adaptive fault line selection method for resonant grounded system based on atomic decomposition[J]. High Voltage Engineering, 2014, 40(11): 3554-3562.
[11]
王 希,王顺超,何金良,等. 10 kV配电线路的雷电感应过电压特性[J]. 高电压技术,2011,37(3):599-605. WANG Xi, WANG Shunchao, HE Jinliang, et al . Characteristics of lightnig induced overvoltage of 10 kV distribution lines[J]. High Voltage Engineering, 2011, 37(3): 599-605.
[12]
司马文霞,冉 锐,袁 涛,等. 采用数学形态学的弧光接地过电压识别方法[J]. 高电压技术,2010,36(4):835-841. SIMA Wenxia, RAN Rui, YUAN Tao, et al . Identification of arc grounding over-voltage using mathematical morphology transform[J]. High Voltage Engineering, 2010, 36(4): 835-841.
[13]
余占清,曾 嵘,王绍安,等. 配电线路雷电感应过电压仿真计算分析[J]. 高电压技术,2013,39(2):415-422. YU Zhanqing, ZENG Rong, WANG Shaoan, et al . Simulation calculation and analysis of lightning induced overvoltage on power distribution lines[J]. High Voltage Engineering, 2013, 39(2): 415-422.
[14]
林 莉,何 月,王军兵,等. 中性点不接地电网单相接地时电压互感器损坏机理[J]. 高电压技术,2013,39(5):1114-1120. LIN Li, HE Yue, WANG Junbing, et al . Mechanism of potential transformer damaged in ungrounded neutral power system[J]. High Voltage Engineering, 2013, 39(5): 1114-1120.
[15]
刘渝根,丁伯剑,陈先禄,等. 山区35 kV电网新型运行方式探讨[J]. 重庆大学学报:自然科学版,2006,29(5):40-43. LIU Yugen, DING Bojian, CHEN Xianlu, et al . New neutral point operation method of 35 kV grids in mountainous area[J]. Journal of Chongqing University: Natural Science Edition, 2006, 29(5): 40-43.
[16]
张 海,徐玉琴,白 嘉,等.10 kV配电网中性点灵活接地方式在单相金属性接地故障下的ATP仿真及其研究[J]. 继电器,2006,4(7):18-23, 42. ZHANG Hai, XU Yuqin, BAI Jia, et al . Research on bolted single-phase ground fault in10kV distribution networkwith flexible ground neutral treatment and itsATP simulation[J]. Relays, 2006, 34(7): 18-23, 42.
[17]
要焕年,曹梅月. 电力系统谐振接地[M]. 北京:中国电力出版社,2009:43-50. YAO Huannian, CAO Meiyue. Resonant grounded of power system[M]. Beijing, China: China Power Press, 2000: 43-50.
[18]
束洪春,高 利,段锐敏,等. 利用零序电流全量Hough变换的配电网故障选线方法[J]. 电力系统自动化,2013,37(9):110-115. SHU Hongchun, GAO Li, DUAN Ruimin, et al . A novel Hough transform approach of fault line selection in distribution networks using total zero-sequence current[J]. Automation of Electric Power Systems, 2013, 37(9): 110-115.
[19]
梁 睿,崔连华,都志立,等. 基于广域行波初始波头时差关系矩阵的配电网故障选线及测距[J]. 高电压技术,2014,40(11):3411-3417. LIANG Rui, CUI Lianhua, DU Zhili, et al . Fault line selection and location in distribution power network based on traveling wave time difference of arrival relationships[J]. High Voltage Engineering, 2014, 40(11): 3411-3417.