王 伟,高超飞,孙 辉,等. 电缆本体空间电荷电声脉冲法测量装置的研制[J]. 高电压技术,2011,37(6):1349-1354. WANG Wei, GAO Chaofei, SUN Hui, et al. Development of cable space charge measurement device using pulsed electro-acoustic[J]. High Voltage Engineering, 2011, 37(6): 1349-1354.
[2]
吴建东,尹 毅,兰 莉,等. 纳米填充浓度对LDPE/Silica 纳米复合介质中空间电荷行为的影响[J]. 中国电机工程学报,2012,32(28):177-183. WU Jiandong, YIN Yi, LAN Li, et al. The influence of nano-filler concentration on space charge behavior in LDPE/Silica nanocomposites[J]. Proceedings of the CSEE, 2012, 32(28): 177-183.
[3]
高 宇,杜伯学. 采用表面电位衰减法表征高压交联聚乙烯电缆绝缘中空间电荷的输运特性[J]. 高电压技术,2012,38(8):2097-2103. GAO Yu, DU Boxue . Characterizing space charge transportation in HV XLPE cable insulation based on surface potential decay measurement[J]. High Voltage Engineering, 2012, 38(8): 2097-2103.
[4]
王 霞,姚 航,吴 锴,等. 交联聚乙烯与硅橡胶界面涂抹不同硅脂对其电荷特性的影响[J]. 高电压技术,2014,40(1):74-79. WANG Xia, YAO Hang, WU Kai, et al. Effect of different coating silicone grease on space charge characteristics at XLPE/SR interface[J]. High Voltage Engineering, 2014, 40(1): 74-79.
[5]
韦延方,卫志农,孙国强,等. 适用于电压源换流器型高压直流输电的模块化多电平换流器最新研究进展[J]. 高电压技术,2012,38(5):1243-1252. WEI Yanfang, WEI Zhinong, SUN Guoqiang, et al. New prospects of modular multilevel converter applied to voltage source converter high voltage direct current transmission[J]. High Voltage Engineering, 2012, 38(5): 1243-1252.
[6]
徐 政,陈海荣. 电压源换流器型直流输电技术综述[J]. 高电压技术,2007,33(1):1-10. XU Zheng, CHEN Hairong . Review and applications of VSC HVDC[J]. High Voltage Engineering, 2007, 33(1): 1-10.
[7]
邱大强,李群湛,南晓强. 电网不对称故障下VSC-HVDC系统的直接功率控制[J]. 高电压技术,2012,38(4):1012-1018. QIU Daqiang, LI Qunzhan, NAN Xiaoqiang . Direct power control of VSC-HVDC system under unsymmetrical fault of grid[J]. High Voltage Engineering, 2012, 38(4): 1012-1018.
Flourentzou N, Agelidis V G, Demetriades G D.VSC-based HVDC power transmission systems: an overview[J]. IEEE Transactions on Power Electronics, 2009, 24(3): 592-602.
[10]
李世强,何旭涛,闫循平,等. 舟山多端柔性直流输电工程的海缆选型及防护探讨[J]. 浙江电力,2013(10):12-15. LI Shiqiang, HE Xutao, YAN Xunping, et al. Disscussion on type selection and protection of submarine cables for Zhoushan multi-terminal flexible DC power transmission project[J]. Zhejiang Electric Power, 2013(10): 12-15.
[11]
CIGRE TB 496 Recommendations for testing DC extruded cable systems for power transmission at a rated voltage up to 500 kV[S], 2012.
[12]
杨黎明,杨荣凯,罗俊华. 220 kV XLPE电缆系统的预鉴定(PQ)试验[J]. 高电压技术,2004,30(增刊1):83-86. YANG Liming, YANG Rongkai, LUO Junhua . PQ test of 220 kV XLPE cable system[J]. High Voltage Engineering, 2004, 30(Supplement 1): 83-86.
[13]
高俊国,于平澜,李紫云,等. 基于有限元法的电缆金属护套感应电压仿真分析[J]. 高电压技术,2014,40(3):714-720. GAO Junguo, YU Pinglan, LI Ziyun, et al. Simulation analysis of induced voltage on metal sheath of power cable based on finite element method[J]. High Voltage Engineering, 2014, 40(3): 714-720.
[14]
IEC 60060-1 High-voltage test technique-part 1: general definition and test requirement[S], 2010.
[15]
IEC 60230 Impulse tests on cables and their accessories[S], 1966.
[16]
宣耀伟,乐彦杰,张娜飞,等. 雷电冲击试验冲击电压发生器调波电阻的确定[J]. 机电工程,2014,31(3):388-392. XUAN Yaowei, LE Yanjie, ZHANG Nafei, et al. Method to determine wave resistance of impulse voltage generator for lightning impulse test[J]. Journal of Mechanical & Electrical Engineering, 2014, 31(3): 388-392.
[17]
朱胜龙,叶剑涛,郁书好. 冲击电压发生器放电回路数学分析及Matlab在其中的应用[J]. 电气应用,2005,24(9):51-54. ZHU Shenglong, YE Jiantao, YU Shuhao . Mathematic analysis for the discharging circuit of impulse voltage generator and application of Matlab[J]. Electrotechnical Application, 2005, 24(9): 51-54.
[18]
臧绪运,赵 刚,孙 伟,等. 3 600 kV冲击电压发生器大负载输出特性[J]. 高电压技术,2002,28(8):14-16. ZANG Xuyun, ZHAO Gang, SUN Wei, et al. Analysis of the capacitive load ability of 3 600 kV serial impulse generator[J]. High Voltage Engineering, 2002, 28(8): 14-16.
[19]
王浩洋,孙 伟,傅正财,等. 负荷对冲击电压发生器输出能力的影响研究[J]. 高压电器,2009,45(5):92-95. WANG Haoyang, SUN Wei, FU Zhengcai, et al. Investigation of load impact on output capability of impulse voltage generator[J]. High Voltage Apparatus, 2009, 45(5): 92-95.
[20]
Hinow M, Hauschild W. Lightning impulse voltage and overshoot evaluation proposed in drafts of IEC 60060-1 and future UHV testing[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2010,17(5):1628-1634.
[21]
司文荣,傅晨钊,黄 华,等. 雷电冲击电压波形 K 因子零相位数字滤波器设计[J]. 电工电工电能新技术,2012,31(2):11-14. SI Wenrong, FU Chenzhao,HUANG Hua, et al. Design of zero-phase digital filter with K factor used in parameters evaluation for lightning impulse[J]. Advanced Technology of Electrical Engineering and Energy, 2012, 31(2): 11-14.
[22]
Ueta G, Tsuboi T, Okabe S, et al .Evaluation of overshoot rate of lightning impulse withstand voltage test waveform based on new base curve fitting methods-study on overshoot waveform in an actual test circuit[J].IEEE Transactions on Dielectrics and Electrical Insulation,2011, 18(3): 783-791.
[23]
Okabe S, Tsuboi T, Ueta G, et al . Basic study of fitting method for base curve extraction in lightning impulse test techniques[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2010, 17(1): 2-4.
[24]
Okabe S, Tsuboi T, Takami J, et al . Evaluation of K -factor based on insulation characteristics under non-standard lightning impulse waceforms[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2009, 16(4): 1124-1126.
[25]
Ueta G, Tsuboi T, Okabe S, et al . K -factor value and front time related characteristics of UHV-class air insulation for positive polarity lightning impulse test[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2012, 19(3): 877-885.