李恒真,刘 刚,李立浧. 绝缘子表面自然污秽成分分析及其研究展望[J]. 中国电机工程学报,2011,31(16):128-137. LI Hengzhen, LIU Gang, LI Licheng. Study status and prospect of natural contamination component on insulator surface[J]. Proceedings of the CSEE, 2011, 31(16): 128-137.
[2]
IEC 60815-1 Selection, and dimensioning of high voltage for polluted conditions, part 1: definitions, information and general principles[S], 2002.
[3]
律方成,秦春旭,郭文义,等. 高海拔地区±800 kV特高压直流输电系统绝缘子带电自然积污特性[J]. 高电压技术,2013,39(3):513-519. LÜ Fangcheng, QIN Chunxu, GUO Wenyi, et al . Natural contamination deposited characteristics of ±800 kV UHV DC insulators at high altitudes[J]. High Voltage Engineering, 2013, 39(3): 513-519.
[4]
蒋兴良,陈爱军,张志劲,等. 盐密和灰密对110 kV复合绝缘子闪络电压的影响[J]. 中国电机工程学报,2006,26(15):150-154. JIANG Xingliang, CHEN Aijun, ZHANG Zhijin, et al . Effect of both saltand non-soluble deposit densities on flashover voltage of 110 kV composite insulator[J]. Proceedings of the CSEE, 2006, 26(15): 150-154.
[5]
舒立春,张志劲,胡 琴,等. 不同伞形结构复合绝缘子的交流污闪有效爬电距离[J]. 电网技术,2011,35(3):146-151. SHU Lichun, ZHANG Zhijin, HU Qin, et al . Utilization coefficient of creepage distance of composite insulators with different umbrella shape configurations in AC pollution flashover process[J]. Power System Technology, 2011, 35(3): 146-151.
[6]
赵晨龙,梅红伟,戴罕奇,等. 自然污秽与人工污秽绝缘子等价性分析方法研究[J]. 中国电机工程学报,2014,34(6):955-964. ZHAO Chenlong, MEI Hongwei, DAI Hanqi, et al . Research on analysis method of equivalence between natural polluted insulators and artificial contaminated insulators[J]. Proceedings of the CSEE, 2014, 34(6): 955-964.
[7]
宿志一. 换流站直流绝缘子的自然积污特性与直交流积污比[C]∥中国电机工程学会高压专委会2007年学术年会论文. 深圳:中国电机工程学会高压专委会,2007:281-290. SU Zhiyi. Study on the pollution characteristics of DC converterstation insulators and the contamination ratio between DC voltage andAC voltage[C]∥2007 Annual Conference Proceedings of High Voltage Special Committee of Chinese Society for Electrical Engineering. Shenzhen, China: High Voltage Special Committee of Chinese Society for Electrical Engineering, 2007: 281-290.
[8]
徐天勇,覃绍先,梅 刚,等. 基于泄漏电流和环境条件的超高压复合绝缘子在线监测与评估[J]. 电瓷避雷器,2014(1):6-15,22. XU Tianyong, QIN Shaoxian, MEI Gang, et al . On-line monitoring and evaluation of EHV composite insulatorsbased on leakage currents and environmental conditions[J]. Insulators and Surge Arresters, 2014(1): 6-15, 22.
[9]
戴罕奇,梅红伟,王希林,等. HTV硅橡胶用不同高岭土染污后的憎水迁移特性对比[J]. 高电压技术,2014,40(4):1030-1037. DAI Hanqi, MEI Hongwei, WANG Xilin, et al . Hydrophobicity transfer feature comparison for HTV silicone rubber polluted by different kaolin[J]. High Voltage Engineering, 2014, 40(4): 1030-1037.
[10]
Goto T, Yonemura T, Hori Y. Artificial contamination tests of siliconerubber cylindrical models[C]∥Proceedings of the 6 th International Conference on Properties and Applications of Dielectric Materials. Xi’an, China: International Electromechanical Commission, 2000: 272-275.
[11]
张志劲,张东东,刘小欢,等. 污秽成分对LXY_4-160绝缘子串交流闪络特性的影响[J]. 电工技术学报,2014,29(4):298-305. ZHANG Zhijin, ZHANG Dongdong, LIU Xiaohuan, et al . Effect of pollution compositions on the AC flashover performance of LXY_4-160 suspension glass insulator string[J]. Transactions of China Electrotechnical Society, 2014, 29(4): 298-305.
[12]
Zhou J G, Dong G, Imakoma T. Contamination performance of outer-rib type suspension insulators[C]∥Transmission and Distribution Conference and Exhibition. Shanghai, China: International Electromechanical Commission, 2002: 2185-2190.
[13]
张志劲,张东东,袁 超,等. 污秽成分对XP-160绝缘子串交流闪络特性的影响[J]. 高电压技术,2014,40(7):1970-1976. ZHANG Zhijin, ZHANG Dongdong, YUAN Chao, et al . Effect of contamination component on AC flashover performance of insulator string XP-160[J]. High Voltage Engineering, 2014, 40(7): 1970-1976.
[14]
刘小欢. 典型伞型结构绝缘子积污特性及其交流污闪特性研究[D]. 重庆:重庆大学,2013. LIU Xiaohuan. Study on the pollution accumulation and AC pollution flashover performance of insulators with typical sheds[D]. Chongqing, China: Chongqing University, 2013.
[15]
张志劲,刘小欢,蒋兴良,等. 污秽不均匀度对XP-160绝缘子串交流闪络特性的影响[J]. 高电压技术,2013,39(2):280-286. ZHANG Zhijin, LIU Xiaohuan, JIANG Xingliang, et al . Effect of non-uniform pollution on the AC flashover performance of XP-160 suspension ceramic insulator string[J]. High Voltage Engineering, 2013, 39(2): 280-286.
[16]
李恒真,刘 刚,李立浧. 自然污秽成分CaSO 4 对电力设备外绝缘沿面绝缘特性的影响综述[J]. 电网技术,2011,35(3):140-145. LI Hengzhen, LIU Gang, LI Licheng. A review on influence of natural contaminant CaSO 4 on surface insulation characteristics of external insulation of power equipment[J]. Power System Technology, 2011, 35(3): 140-145.
[17]
IEC. Artificial pollution tests on high voltage insulators to be used on AC systems[R]. Geneva, Swiss: IEC, 1991.
[18]
GB/T4585—2004 交流系统用高压绝缘子的人工污秽[S],2004. GB/T 4585—2004 Artificial pollution tests on high-voltage insulators to be used on AC systems[S], 2004.
[19]
张志劲,苏永祥,蒋兴良,等. 试验程序差异对绝缘子污闪电压的影响[J]. 高电压技术,2013,39(5):1089-1095. ZHANG Zhijin, SU Yongxiang, JIANG Xingliang, et al . Influence of differences in experimental procedures on flashover voltage for polluted insulators[J]. High Voltage Engineering, 2013, 39(5): 1089-1095
[20]
张志劲,蒋兴良,孙才新,等. 高海拔现场与人工气候室下绝缘子交流污闪特性的比较[J]. 电网技术,2012,36(2):163-169. ZHANG Zhijin, JIANG Xingliang, SUN Caixin, et al . Comparison of AC pollution flashover performances of insulatorsin high altitude sites with that in chamber climate[J]. Power System Technology, 2012, 36(2): 163-169.
[21]
Sun C X, Tian Y, Jiang X L, et al . Flashover performance and voltage correction of iced and polluted HV insulator stringat high altitude of 4 000 m and above[C]∥7 th International Conference Properties and Applications of Dielectric Materials. Nagoya, Japan:[s. n.], 2003: 141-145.
[22]
王少华,胡文堂,何文林,等. 自然积污绝缘子的污闪电压和泄漏电流特性试验研究[J]. 电网技术,2013,37(10):2855-2860. WANG Shaohua, HU Wentang, HE Wenlin, et al . Experimental research on pollution flashover voltage and leakage current characteristics of naturally polluted insulators[J]. Power System Technology, 2013, 37(10): 2855-2860.
[23]
蒋兴良,石 岩,黄 欢,等. 污秽绝缘子泄漏电流频率和相位特征的试验研究[J]. 中国电机工程学报,2010,30(7):118-124. JIANG Xingliang, SHI Yan, HUANG Huan, et al . Experimental research on the frequency and phase characteristics of leakage current of artificially polluted insulators[J]. Proceedings of the CSEE, 2010, 30(7): 118-124.
[24]
张志劲,蒋兴良,孙才新. 污秽绝缘子闪络特性研究现状及展望[J]. 电网技术,2006,30(2):35-40. ZHANG Zhijin, JIANG Xingliang, SUN Caixin. Present situation and prospect of research on flashover characteristics of polluted insulators[J]. Power System Technology, 2006, 30(2): 35-40.