全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...

隔膜电解法回收利用电厂锅炉EDTA清洗废水研究

Keywords: 电厂锅炉EDTA清洗废水,隔膜电解,电流,阴极电解液初始pH值,Fe/EDTA摩尔比

Full-Text   Cite this paper   Add to My Lib

Abstract:

以涂Ir/Sn钛网板作阳极,以不锈钢网板作阴极,采用隔膜电解法处理电厂锅炉EDTA清洗废水。实验结果表明,电流、阴极电解液初始pH值和Fe/EDTA摩尔比对粉末铁析出速率影响较大,粉末铁电解析出的适宜条件是电解电流为1.0A、阴极电解液初始pH值为5.6、阴极电解液Fe/EDTA摩尔比足够高。采用隔膜电解结合反渗透膜系统处理电厂锅炉EDTA清洗废水,可同时高效回收纳米级粉末铁和EDTA。

References

[1]  曹路,李正奉.火电机组锅炉的EDTA化学清洗.清洗世界,2004,20(8):18~22
[2]  张国卿.电厂锅炉有机酸清洗废水处理研究[硕士学位论文].上海:上海大学,2004
[3]  Vladimir Sykoka,Pavel Pitter,et al.Biodegradability of ethylenediamine-based complexing agents.Water Research,2001,35 (8):2010~2016
[4]  杨晓奕,邓建利,等.乙二胺四乙酸(EDTA)生物降解特性.环境科学,2001,22(2):41~45
[5]  王罗春,闻人勤,丁桓如.EDTA废水处理研究现状及其展望.环境保护科学,2003,29(6):11~14
[6]  Larry J.Holcombe,Greg P.Behrens,Wayne C.Micheletti.Methods for removal of copper and iron from boiler chemical cleaning wastes.Environmental Progress,1987,6(2):74~81
[7]  董永全,黄万抚.隔膜电解技术的应用和发展.江西有色金属,2002,16(3):35~38
[8]  李泰康,黄小兵,等.含铁酸洗废液中分离酸和提取电解铁粉的研究.粉末冶金工业,2002,12(4):37~41
[9]  Ruey-Shin Juang,Shiow-Wen Wang.Metal recovery and EDTA recycling from simulated washing effluents of metal contaminated soils.Water Research,2000,34 (15):3795~3803
[10]  Ruey-Shin Juang,Shiow-Wen Wang.Electrolytic recovery of binary metals and EDTA from strong complexed solutions.Water Research,2000,34(12):3179~3185
[11]  Chaudhary A.J.,Donaldson J.D.,et al.Separation of nickel from cobalt using electrodialysis in the presence of EDTA.Journal of Applied Electrochemistry,2000,30:439~445
[12]  Ruey-Shin Juang,Shiow-Wen Wang,Li-Chun Lin.Simultaneous recovery of EDTA and lead(Ⅱ) from their chelated solutions using a cation exchange membrane.Membrane Science,1999,160:225~233
[13]  Ruey-Shin Juang,Li-Chun Lin.Rates of metal electrodeposition from aqueous solutions in the presence of chelating agents.Seperation Science and Technology,2000,35(7):1087~1098
[14]  Ruey-Shin Juang,Li-Chun Lin.Treatment of complexed copper (Ⅱ) solutions with electrochemical membrane processes.Water Research,2000,34 (1):43~50
[15]  Huang C.P.,Mei-Chih Hsu,Paul Miller.Recovery of EDTA from plant boiler chemical cleaning waste.Journal of Environmental Engineering,2002,126 (10):919~924
[16]  Allen A.E.,Chen P.H.Remediation of metal contaminated soil by EDTA incorporating electrochemical recovery of metal and EDTA.Environmental Progress,1993,(12):284~293
[17]  宋卫锋.DSA类电极电降解苯胺、苯酚和硝基苯过程的研究[博士学位论文].上海:同济大学,2000
[18]  陶自春,罗启富,等.铱系涂层钛阳极的研究进展.材料科学与工程学报,2003,21(1):138~142
[19]  中国标准出版社第二编辑室编.火力发电厂水汽试验方法标准规范汇编.北京:中国标准出版社,2000.318~319
[20]  周英.用EDTA清洗锅炉时清洗液中含铁量测定方法的讨论.中国锅炉压力容器安全,2002,18(6):67~69