MBBR处理猪场废水厌氧消化液的研究

Keywords: 移动床生物膜反应器,猪场废水厌氧消化液,COD,NH3-N

Full-Text   Cite this paper   Add to My Lib

Abstract:

采用移动床生物膜反应器(MBBR)处理猪场废水厌氧消化液,考察了水力停留时间(HRT),进水COD和NH3-N浓度对反应器处理效果的影响。结果表明,在温度为20~30℃,填料填充比为50%,进水COD和NH3-N浓度分别为1016mg/L和496mg/L条件下,当HRT为12.5h时,COD和NH3-N去除率可分别达到62%和77%,猪场废水厌氧消化液中可生物降解性有机物基本得到去除,当HRT增至23.8h时,COD和NH

References

[1]  Matias B.,Ariel A.,Patrick G.,et al.Development of environmentally superior treatment system to reep]ace anaerobic swine lagoons in the USA.Bioresource Technology,2007,98:3184~3194
[2]  Edgerton B.D.,McNevin D.,Wong C.H.,et al.Strategies for dealing with piggery effluent in Australia:The sequencing batch reactor as a solution.Wat.Sci.Tech.,1999,41 (1):123~126
[3]  Bernet N.,Delgenes N.,Akunna C.,et al.Anerobic aerobic SBR for the treatment of piggery wastewater.Wat.Res.,1999,34(2):611~619
[4]  Rusten B.,Bjφrnar E.,Ulgenes Y.,et al.Design and operations of the Kaldnes moving bed biofilm reactors.Aquacultural Engineering,2006,34:322~331
[5]  Comett-Ambriz I.,Gonzalez-Martinez S.,Wilderer P.Comparison of the performance of MBBR and SBR systems for the treatment of anaerobic reactor biowaste effluent.Wat.Sci.Technol.,2003,47(12):155~161
[6]  Plattes M.,Henry E.,Schosseler P.M.,et al.Model-ling and dynamic simulation of a moving bed bioreactor for the treatment of municipal waste-water.Biochemical Engineering Journal,2006,32:61~68
[7]  Luostarinen S.,Luste S.,Valentin L.,et al.Nitrogen removal from on-site treated anaerobic effluents using intermittently aerated moving bed biofilm reactors at low temperatures.War.Res.,2006,40:1607~1615
[8]  Chen S.,Sun D.Z.,Chung J.S.Treatment of pesticide wastewater by moving-bed biofilm reactorcombined with Fenton-coagulation pretreatment.Journal of Hazardous Materials,2007,144:577~584
[9]  胡龙兴,赵江冰,M.Baudu.MBBR处理模拟城市污水的工艺条件.上海大学学报,2005,11(2):202~210

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133