电网技术  2010 

染污方式对复合绝缘子交流覆冰闪络特性的影响

, PP. 216-219

Full-Text   Cite this paper   Add to My Lib

Abstract:

在人工气候室内分别对2种染污方式(固体涂层法、覆冰水电导率法)下,FXBW–10/70、FXBW–35/702种复合绝缘子进行了试验研究,得到了2种染污方式的等价关系,并分析了2种染污方式对试验结果和复合绝缘子闪络过程的影响。试验结果表明,覆冰水电导率(20℃)与盐密呈幂指数关系,并且特征指数与复合绝缘子型式无明显关系;固体涂层法试验结果的分散性比覆冰水电导率法大;2种染污方式的闪络发展过程存在差异,固体涂层法对复合绝缘子的破坏较覆冰水电导率法要大。

References

[1]  李庆峰,范峥,吴穹,等.全国输电线路覆冰情况调研及事故分析[J].电网技术,2008,32(9):33-36.
[2]  Li Qingfeng,Fan Zheng,Wu Qiong,et al.Investigation of ice-covered transmission lines and analysis on transmission line failures caused by ice-coating in China[J].Power System Technology,2008,32(9):33-36(in Chinese).
[3]  蒋兴良,易辉.输电线路覆冰及防护[M].北京:中国电力出版社,2001:1-9.
[4]  蒋兴良,苑吉河,孙才新,等.我国±800 kV 特高压直流输电线路外绝缘问题[J].电网技术,2006,30(9):1-9.
[5]  Jiang Xingliang,Yuan Jihe,Sun Caixin,et al.External insulation of ±800 kV UHV DC power transmission lines in China[J].Power System Technology,2006,30(9):1-9(in Chinese).
[6]  蒋兴良,苑吉河,孙才新,等.绝缘子覆冰及其电气试验方法探讨[J].高电压技术,2005,31(5):4-6.
[7]  Jiang Xingliang,Yuan Jihe,Sun Caixin,et al.Insulators icing and electrical tests methods[J].High Voltage Engineering,2005,31(5):4-6(in Chinese).
[8]  Farzaneh M,Baker T,Brown K,et al.Insulator icing test methods and procedure[J].IEEE Transactions on Power Delivery,2003,18(4):1503-1515.
[9]  田玉春,蒋兴良,舒立春.高海拔地区10 kV合成绝缘子覆冰闪络特性[J].高电压技术,2002,28(6):13-15.
[10]  Tian Yuchun,Jiang Xingliang,Shu Lichun.AC flashover performance and voltage correction of iced 10kV composite insulator in high altitude area [J].High Voltage Engineering,2002,28(6):13-15(in Chinese).
[11]  司马文霞,蒋兴良,武利会,等.低气压下覆冰染污10kV合成绝缘子直流电气特性[J].中国电机工程学报,2004,24(7):122-126.
[12]  Sima Wenxia,Jiang Xingliang,Wu Lihui,et al.DC electrical performance of icing and polluted 10kV composite insulator at low atmospheric pressures[J].Proceedings of the CSEE,2004,24(7):122-126(in Chinese).
[13]  蒋兴良,王波,张志劲,等.串长及布置方式对高海拔覆冰绝缘子串直流冰闪电压的影响[J].中国电机工程学报,2008,28(3):1-5.
[14]  Jiang Xingliang,Wang Bo,Zhang Zhijin,et al.Influence of length and arrangement of iced insulator strings on DC flashover voltage at high altitude districts[J].Proceedings of the CSEE,2008,28(3):1-5(in Chinese).
[15]  蒋兴良,舒立春,张志劲,等.覆冰绝缘子长串交流闪络特性和放电过程研究[J].中国电机工程学报,2005,25(14):158-163.
[16]  Jiang Xingliang,Shu Lichun,Zhang Zhijing,et al.Study on AC flashover performance and Process of Long Iced Insulator Strings [J].Proceedings of the CSEE,2005,25(14):158-163(in Chinese).
[17]  盛道伟,蒋兴良,苑吉河,等.覆冰XP-160型绝缘子串的操作冲击闪络特性[J].电网技术,2008,32(11):95-98.
[18]  Sheng Daowei,Jiang Xingliang,Yuan Jihe,et al.Flashover performance of ice-covered XP-160 type insulator string under switching impulse[J].Power System Technology,2008,32(11):95-98(in Chinese).
[19]  Ravelomanantsoal N,Farzanehl M,Chisholm W A.Insulator pollution processes under winter condition[C].Annual Report Conference on Electrical Insulation and Dielectric Phenomena,2005.
[20]  舒立春,蒋兴良,田玉春,等.海拔4 000 m以上地区4种合成绝缘子覆冰交流闪络特性及电压校正[J].中国电机工程学报,2004,24(1):97-101.
[21]  Shu Lichun,Jiang Xingliang,Tian Yuchun,et al.AC flashover performance and voltage correction of four types of iced composite insulator at altitude 4 000 m above[J].Proceedings of the CSEE,2004,24(1):97-101(in Chinese).
[22]  张志劲,蒋兴良,孙才新,等.低气压下特高压直流污秽复合绝缘子覆冰闪络特性[J].中国电机工程学报,2008,28(6):7-12.
[23]  Zhang Zhijin,Jiang Xingliang,Sun Caixin,et al.Icing flashover performance of UHV DC composite insulators at low atmospheric pressure[J].Proceedings of the CSEE,2008,28(6):7-12(in Chinese).
[24]  孙才新,司马文霞,舒立春.大气环境与电气外绝缘[M].北京:中国电力出版社,2002:81-97.
[25]  李鹏,范建斌,李武峰,等.高压直流输电线路的覆冰闪络特性[J].电网技术,2006,30(19):74-78.
[26]  Li Peng,Fan Jianbin,Li Wufeng,et al.Icing flashover performance of HVDC transmission lines[J].Power System Technology,2006,30(19):74-78(in Chinese).
[27]  胡毅.电网大面积冰灾分析及对策探讨[J].高电压技术,2008,34(2):215-219.
[28]  Hu Yi.Analysis and countermeasures discussion for large area icing accident on power grid[J].High Voltage Engineering,2008,34(2):215-219(in Chinese).
[29]  张文亮,于永清,宿志一,等.湖南电网2008年冰雪灾害调研分析[J].电网技术,2008,32(8):1-5.
[30]  Zhang Wenliang,Yu Yongqing,Su Zhiyi,et al.Investigation and analysis of icing and snowing disaster happened in hunan power grid in 2008[J].Power System Technology,2008,32(8):1-5(in Chinese).

Full-Text