电网技术  2006 

复合绝缘子在±800kV特高压直流工程中的应用研究

, PP. 8-11

Keywords: 特高压直流输电,复合绝缘子,污秽,老化

Full-Text   Cite this paper   Add to My Lib

Abstract:

我国±800kV特高压直流输电工程面临着高海拔和重污秽等问题。复合绝缘子即使在憎水性完全丧失的条件下,其污闪电压仍然比同等污秽度下瓷和玻璃绝缘子串的污闪电压高出很多,因此在±800kV特高压直流输电工程中使用复合绝缘子是必要且可行的。在应用过程中应考虑并解决高海拔强紫外线辐射所带来的伞裙护套老化、大吨位复合绝缘子的长期可靠性以及高压端电场分布等技术问题。

References

[1]  Shu Yinbiao,Liu Zehong,Gao Liying,et al.A preliminary exploration for design of ±800 kV UHVDC project with transmission capacity of 6400MW[J].Power System Technology,2006,30(1):1-8.
[2]  吴敬儒,徐永禧.我国特高压交流输电发展前景[J].电网技术,2005,29(3):1-4.
[3]  Wu Jingru,Xu Yongxi.Development prospect of UHV AC power transmission in China[J].Power System Technology,2005,29(3):1-4.
[4]  项立人.应该加快我国特高压输电前期工作的研究[J].电网技术,1996,20(2):54-58.
[5]  Xiang Liren.Speed up earlier UHV transmission research in China [J].Power System Technology,1996,20(2):54-58.
[6]  张运洲.对我国特高压输电规划中几个问题的探讨[J].电网技术,2005,29(19):11-14.
[7]  Zhang Yunzhou.Discussion of several problems on UHV transmission programming of China[J].Power System Technology,2005,29(19):11-14.
[8]  Guo Ricai,Li Ming,Xu Xiaodong,et al. Research and suggestions on speeding up dissemination and application of new technologies for power grid construction[J].Power System Technology,2006,30(2):23-29.
[9]  CIGRE WG22.03.Service performance of composite insulators used on HVDC lines[J].Electra,1995,161:52-57.
[10]  李武峰.±500kV直流绝缘子串和支柱绝缘子的污闪特性[R].北京:中国电力科学研究院,2004.
[11]  王珣.紫外辐射对硅橡胶合成绝缘子老化作用的研究[D].北京:清华大学,2005.
[12]  孙昌富,梁曦东,周远翔,等.合成绝缘子动载性能的研究[J].电网技术,2001,26(12):33-36.
[13]  Sun Changfu,Liang Xidong,Zhou Yuanxiang,et al.Research on dynamic load properties of composite insulators[J].Power System Technology,2001,26(12):33-36.
[14]  张畅生,王晓刚.500 kV惠汕线合成绝缘子芯棒脆断事故分析[J].电网技术,2002,26(6):71-73.
[15]  Zhang Changsheng,Wang Xiaogang.Analysis of composite insulator mandrill breaking on 500kV Huishan line[J].Power System Technology,2002,26(6):71-73.
[16]  Armentrout D L,Kumosa M,McQuarrie T S.Boron-free fibers for prevention of acid induced brittle fracture of composite insulator GRP rods[J].IEEE Transactions on Power Delivery,2003,18(3):684-692.
[17]  Megel M,Kumosa L,Ely T,et al.Initiation of stress-corrosion cracking in unidirectional glass/polymer composite materials [J].Composites Science and Technology,2001,61(2):231-246.
[18]  张鸣,陈勉.500 kV罗北甲线合成绝缘子芯棒脆断原因分析[J].电网技术,2003,27(12):51-53.
[19]  Zhang Ming,Chen Mian.Analysis on core brittle fracture of composite insulators in a certain 500kV transmission line[J].Power System Technology,2003,27(12):51-53.
[20]  Phillips A J,Childs D J,Schneider H M.Aging of non-ceramic insulators due to corona from water drops[J].IEEE Trans on Power Delivery,14,3:1081-1089.
[21]  崔江流,宿志一,易辉.我国硅橡胶复合绝缘子的应用与展望[J].中国电力,1999,32 (1):38-41.
[22]  Cui Jiangliu,Su Zhiyi,Yi Hui.The application and its prospect of silicon rubber composite insulators in China[J].Electric Power,1999, 32(1):38-41.
[23]  周浩,余宇红.我国发展特高压输电中一些重要问题的讨论[J].电网技术,2005,29(12):1-8.
[24]  Zhou Hao,Yu Yuhong.Discussion on several important problems of development UHV AC transmission in China[J].Power System Technology,2005,29(12):1-8.
[25]  朱鸣海.关于发展我国特高压输电的意见[J].电网技术,1995,19(3):54-57.
[26]  Zhu Minghai.Some problems on development of UHV power transmission in China[J].Power System Technology,1995,19(3):54-57.
[27]  舒印彪,刘泽洪,高理迎,等.±800 kV 6 400 MW特高压直流输电工程设计[J].电网技术,2006,30(1):1-8.
[28]  郭日彩,李明,徐晓东,等.加快电网建设新技术推广应用的研究与建议[J].电网技术,2006,30(2):23-29.
[29]  Ely T,Kumosa M.Stress corrosion experiments on an E-glass/epoxy unidirectional composite[J].Journal of Composite Materials,2000, 34(10):841-878.