输电线路行波故障测距的关键在于对故障行波波头的识别和定位。为实现准确故障测距,应用一种新的信号处理方法,从行波能量的角度出发,利用时窗滚动计算的能量比函数法来处理故障行波,以此计算波头时延,实现故障测距。研究了不同时间窗宽度对定位准确度的影响,以此选择合理的时间窗进行能量比计算,并分析了复杂环境干扰下能量比法的测距精度。ATP/EMTP仿真试验数据处理结果表明,该方法准确有效,而且计算简便快捷,在低信噪比环境下有很好的抗干扰能力。

References

[1]  Huang Xiong,Yin Xianggen,Xin Zhentao.Fault locating algorithm for double-circuit line based on distributed parameter[J].Electric Power Automation Equipment,2003,23(11):5-8(in Chinese).
[2]  董新洲,葛耀中,徐丙垠.利用暂态电流行波的输电线路故障测距研究[J].中国电机工程学报,1999,19(4):76-80.
[3]  Dong Xinzhou,Ge Yaozhong,Xu Bingyin.Research of fault location based on current traveling waves[J].Proceedings of the CSEE,1999,
[4]  葛耀中.新型继电保护和故障测距的原理与技术[M].西安:西安交通大学出版社,2007:258-331.
[5]  Poission Q,Rioual P,Meunier M.New signal processing tools applied to power quality analysis[J].IEEE Trans on Power Delivery,1999,14(2):561-566.
[6]  马丹丹,王晓茹.基于小波模极大值的单端行波故障测距[J].电力系统保护与控制,2009,37(3):55-59.
[7]  Ma Dandan,Wang Xiaoru.Single terminal methods of traveling wave fault location based on wavelet modulus maxima[J].Power System Protection and Control,2009,37(3):55-59(in Chinese).
[8]  余畅,尹项根,曾祥君,等.基于小波分析的多尺度下综合行波故障定位[J].电力自动化设备,2001,21(6):6-9.
[9]  Yu Chang,Yin Xianggen,Zeng Xiangjun,et al.Fault location based on comprehensive wavelet analysis at different scales[J].Electric Power Automation Equipment,2001,21(6):6-9(in Chinese).
[10]  黄雄,王志华,尹项根.高压输电线路行波测距的行波波速确定方法[J].电网技术,2004,28(19):34-37.
[11]  Huang Xiong,Wang Zhihua,Yin Xianggen.Travelling wave velocity measurement in fault location based on travelling wave for high voltage transmission line[J].Power System Technology,2004,28(19):34-37(in Chinese).
[12]  王勇,曹保定,姜涛.电子式互感器合并单元的快速数据处理[J].电网技术,2009,33(1):87-91.
[13]  Wang Yong,Cao Baoding,Jiang Tao.Fast data processing for merging unit of electronic transformer[J].Power System Technology,2009,33(1):87-91(in Chinese).
[14]  王昌长,李福琪,高胜友.电力设备的在线监测与故障诊断[M].北京:清华大学出版社,2006:251-273.
[15]  全玉生,杨敏中,王晓蓉,等.高压架空输电线路的故障测距方法[J].电网技术,2000,24(4):27-33.
[16]  Quan Yusheng,Yang Minzhong,Wang Xiaorong,et al.A fault location method for overhead high voltage power transmission lines [J].Power System Technology,2000,24(4):27-33(in Chinese).
[17]  邬林勇,何正友,钱清泉.单端行波故障测距的频域方法[J].中国电机工程学报,2008,
[18]  Wu Linyong,He Zhengyou,Qian Qingquan.A frequency domain approach to sinle-ended traveling wave fault location[J].Proceedings of the CSEE,2008,28(25):99-104(in Chinese).
[19]  邬林勇,何正友,钱清泉.一种提取行波自然频率的单端故障测距方法[J].中国电机工程学报,2008,28(10):69-75.
[20]  Wu Linyong,He Zhengyou,Qian Qingquan.A single ended fault location method using traveling wave natural frequency[J].Proceedings of the CSEE,2008,28(10):69-75(in Chinese).
[21]  李友军,王俊生,郑玉平,等.几种行波测距算法的比较[J].电力系统自动化,2001,25(14):36-39.
[22]  Li Youjun,Wang Junsheng,Zheng Yuping,et al.Comparison of several algorithms of travelling wave base fault location[J].Automation of Electric Power Systems,2001,25(14):36-39(in Chinese).
[23]  郑州,吕艳萍,王杰,等.基于小波变换的双端行波测距新方法[J].电网技术,2010,34(1):203-207.
[24]  Zheng Zhou,Lü Yanping,Wang Jie,et al.A new two-terminal traveling wave fault location method based on wavelet transform[J].Power System Technology,2010,34(1):203-207(in Chinese).
[25]  李廷伟,姬广展,王鹰,等.一种改进的输电线路双端行波故障测距系统[J].电网技术,2008,32(1):90-92.
[26]  Li Tingwei,Ji Guangzhan,Wang Ying,et al.An improved double traveling wave fault location system for transmission line[J].Power System Technology,2008,32(1):90-92(in Chinese).
[27]  王颖,王增平,潘明九.故障测距法在输电线路保护中的应用[J].电力自动化设备,2003,23(12):34-38.
[28]  Wang Ying,Wang Zengping,Pan Mingjiu.Application of fault locating in line protection[J].Electric Power Automation Equipment,2003,23(12):34-38(in Chinese).
[29]  黄雄,尹项根,辛振涛.基于分布参数模型的平行双回线故障测距新算法[J].电力自动化设备,2003,23(11):5-8.
[30]  贝达物,皮尔索.相关分析与谱分析方法的工程应用[M].凌福根,译.北京:国防工业出版社,1983:47-60.
[31]  毛汉领,陈仲仪,庄红宇.能量比时间延迟估计法及在定位中的应用[J].广西工学院学报,1994,5(2):12-16.
[32]  Mao Hanling,Chen Zhongyi,Zhuang Hongyu.The time delay estimate on based on energy ration and its application on the localization[J].Journal of Guangxi Institute of Technology,1994,5(2):12-16(in Chinese).
[33]  左国平,王彦春,隋荣亮.利用能量比法拾取地震初至的一种改进方法[J].石油物探,2004,43(4):35-37.
[34]  Zuo Guoping,Wang Yanchun,Sui Rongliang.An improved method for first arrival pickup using energy ratio[J].Geophysical Prospecting for Petroleum,2004,43(4):35-37(in Chinese).
[35]  卢毅,姜玉磊,杨静.能量比函数法估算局部放电时延[J].高电压技术,2007,33(5):87-89.
[36]  Lu Yi,Jiang Yulei,Yang Jing.Research on delay estimation of partial discharges based on energy ratio function[J].High Voltage Engineering,2007,33(5):87-89(in Chinese).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133