孙恒明,曹继丰.高压直流换流器差动保护抗干扰性能研究[J].南方电网技术,2009,2(5):28-31. Sun Hengming,Cao Jifeng.Study on Anti-jamming performance of differential protection in HVDC converter[J].Southern Power System Technology,2009,2(5):28-31(in Chinese).
[2]
成敬周,徐政,张静.交流系统横向故障对HVDC100Hz保护影响及特性分析[J].电网技术,2011,35(9):223-228. Cheng Jingzhou,Xu Zheng,Zhang Jing.Innuence of transverse faults in HVAC power system on HVDC 100 Hz protection of HVDC transmission system and analysis on its characteristics[J].Power System Technology,2011,35(9):223-228(in Chinese).
[3]
李新年,易俊,李柏青,等.直流输电系统换相失败仿真分析及运行情况统计[J].电网技术,2012,36(6):266-271. Li Xinnian,Yi Jun,Li Baiqing,et al.Simulation analysis and operation statistics of commutation failure in HVDC transmission system[J].Power System Technology,2012,36(6):266-271(in Chinese).
[4]
高爱云,聂娟红,李晓华,等.换流变压器阀侧单相接地故障保护动作分析[J].电工电能新技术,2010,29(4):71-75.Gao Aiyun,Nie Juanhong,Li Xiaohua,et al.Protection analysis of single-phase ground fault[J].Advanced Technology of Electrical Engineering and Energy,2010,29(4):71-75(in Chinese).
[5]
张颖,邰能灵,徐斌.高压直流输电系统阀短路保护动作特性分析[J].电力系统自动化,2011,35(8):97-102. Zhang Ying,Tai Nengling,Xu Bin.Operation characteristics analysis for valve short-circuit protection in HVDC system[J].Automation of Electric Power Systems,2011,35(8):97-102(in Chinese).
[6]
梅念,李银红,刘登峰,等.高压直流输电中阀短路保护的动作方程研究[J].中国电机工程学报,2009,29(1):40-47. Mei Nian,Li Yinhong,Liu Dengfeng,et al.Study on the operational equation for valve short circuit protections in HVDC projects[J].Proceedings of the CSEE,2009,29(1):40-47(in Chinese).
[7]
张民,石岩,韩伟.特高压直流保护动作策略的研究[J].电网技术,2007,31(10):10-16. Zhang Min,Shi Yan,Han Wei.Research on action strategy of UHVDC protection[J].Power System Technology,2007,31(10):10-16(in Chinese).
[8]
Darwish H A,Taalab A I,Rahman M A.Performance of HVDC converter protection during internal faults[C]//IEEE Power Engineering Society General Meeting.Montreal,Que:IEEE,2006:7.
[9]
李晓华,刘洋,蔡泽祥.直流输电换流变压器阀侧交流单相接地故障[J].电工技术学报,2012,27(6):38-45. Li Xiaohua,Liu Yang,Cai Zexiang.Analysis of grounding fault at HVDC converter transformer valve side[J].Transactions of China Electrotechnical Society,2012,27(6):38-45(in Chinese).
[10]
郑涛,祁欢欢,范莹.基于阀短路保护的HVDC换流器区内故障定位新方法[J].电力系统自动化,2013,37(5):99-104. Zheng Tao,Qi Huanhuan,Fan Ying.A new valve short-circuit protection based method for identifying fault locations in HVDC converters[J].Automation of Electric Power Systems,2013,37(5):99-104(in Chinese).
[11]
韩昆仑,蔡泽祥,李佳曼,等.考虑直流控制的换流器交流侧故障及其保护动作行为分析[J].高电压技术,2014,40(8):2531-2540. Han Kunlun,Cai Zexiang,Li Jiaman,et al.Analysis of fault on the AC side of converter and action of converter protection considering DC control[J].High Voltage Engineering,2014,40(8):2531-2540(in Chinese).
[12]
Elserougi A A,Abdel-Khalik A,Massoud A,et al.A new protection scheme for HVDC converters against DC-side faults with current suppression capability[J].IEEE Transactions on Power Delivery,2014,29(4):1569-1577.
[13]
成敬周,徐政.换流站内的交流系统故障分析及保护动作特性研究[J].中国电机工程学报,2011,31(22):88-95. Cheng Jingzhou,Xu Zheng.Analysis of AC faults in converter station and characteristics of its relay protection[J].Proceedings of the CSEE,2011,31(22):88-95(in Chinese).
[14]
查鲲鹏,周万迪,高冲,等.高压直流换流阀例行试验方法研究及工程实践[J].电网技术,2013,37(2):466-470. Zha Kunpeng,Zhou Wandi,Gao Chong,et al.Research on routine test of HVDC converter valve and its engineering practice[J].Power System Technology,2013,37(2):466-470(in Chinese).
[15]
雷霄,许自强,王华伟,等.±800 kV 特高压直流输电工程实际控制保护系统仿真建模方法与应用[J].电网技术,2013,37(5):1359-1346. Lei Xiao,Xu Ziqiang,Wang Huawei,et al.A modeling method for actual control and protection system of ±800kV UHVDC transmission project and its application[J].Power System Technology,2013,37(5):1359-1346(in Chinese).
[16]
梁旭明,张平,常勇.高压直流输电技术现状及发展前景[J].电网技术,2012,36(4):1-9. Liang Xuming,Zhang Ping,Chang Yong.Recent advances in high-voltage direct-current power transmission and its developing potential[J].Power System Technology,2012,36(4):1-9(in Chinese).
[17]
张文亮,汤涌,曾南超.多端高压直流输电技术及应用前景[J].电网技术,2010,34(9):1-6. Zhang Wenliang,Tang Yong,Zeng Nanchao.Multi-terminal HVDC transmission technologies and its application prospects in China[J].Power System Technology,2010,34(9):1-6(in Chinese).
[18]
郑伟,张楠,周全.和应涌流导致直流闭锁极保护误动作分析[J].电力系统自动化,2013,37(11):119-124. Zheng Wei,Zhang Nan,Zhou Quan.Analysis of DC blocked pole protection misoperation caused by sympathetic inrush current[J].Automation of Electric Power Systems,2013,37(11):119-124(in Chinese).
[19]
刘敏,张楠,邹卓霖,等.直流保护系统 TA 饱和引起直流工程桥差保护误动分析及改进措施[J].电力系统保护与控制,2007,35(21):10-13. Liu Min,Zhang Nan,Zou Zhuolin,et al.Analysis of a unwanted trip of the bridge differential protection caused by CT saturation state and its improved ways[J].Power System Protection and Control,2007,35(21):10-13(in Chinese).
[20]
汪道勇,黄道春,崔雨,等.葛洲坝换流站D桥差动保护动作原因及整改[J].高电压技术,2008,34(7):1504-1508. Wang Daoyong,Huang Daochun,Cui Yu,et al.Reasons of differential protection action and reform measures for Gezhouba converter station D bridge[J].High Voltage Engineering,2008,34(7):1504-1508(in Chinese).
[21]
谢惠藩,杨光源,彭光强,等.云广特高压直流差动保护误动原因分析[J].电力系统自动化,2013,37(14):130-135. Xie Huifan,Yang Guangyuan,Peng Guangqiang,et al.Malfunction analysis on DC differential protection of Yunnan-Guangdong UHVDC[J].Automation of Electric Power Systems,2013,37(14):130-135(in Chinese).