[1] | U.S.-Canada Power Systems Outage Task Force.Final report on the August 14, 2003 blackout in the United States and Canada [EB/OL].http://www.ferc.gov/,2004-04.
|
[2] | 刘永奇,谢开.从调度角度分析8.14美加大停电[J].电网技术,2004,28(8):11-15.
|
[3] | Liu Yongqi,Xie Kai.Analysis on blackout of interconnection North America power grid occurred on Aug.14, 2003 from the viewpoint of power system dispatching[J].Power System Technology,2004,28(8):11-15(in Chinese).
|
[4] | 印永华,郭剑波,赵建军,等.美加“8.14”大停电事故初步分析以及应吸取的教训[J].电网技术,2003,27(10):8-11.
|
[5] | Yin Yonghua,Guo Jianbo,Zhao Jianjun,et al.Preliminary analysis of large scale blackout in interconnection North America power grid on August 14 and lessons to be drawn[J].Power System Technology,2003,27(10):8-11(in Chinese).
|
[6] | 何大愚.一年以后对美加“8.14”大停电事故的反思[J].电网技术,2004,28(21):1-5.
|
[7] | He Dayu.Rethinking over ‘8.14’ Us-Canada blackout after one year [J].Power System Technology,2004,28(21):1-5(in Chinese).
|
[8] | 韩祯祥,曹一家.电力系统的安全性及防治措施[J].电网技术,2004,28(9):1-6.
|
[9] | Han Zhenxiang,Cao Yijia.Power system security and its prevention [J].Power System Technology,2004,28(9):1-6(in Chinese).
|
[10] | Xu Huiming,Bi Tianshu,Huang Shaofeng,et al.Study of wide-area back-up protection for power systems[C].2005 International Conference of Electrical Engineering,2005.
|
[11] | 国家电力调度通信中心.电力系统实时动态监测系统技术规范(试行)[Z].北京:国家电力调度通信中心,2003.
|
[12] | Wang Yingtao,Yin Yonghua,Jiang Yiguo,et al.Study on current development situation and implementation strategy of real-time dynamic monitoring system in power systems in China[J].Power System Technology,2005,29(11):44-48(in Chinese).
|
[13] | 毛安家,郭志忠.与SCADA互补的WAMS中PMU的配置及数据处理方法[J].电网技术,2005,29(8):71-74.
|
[14] | Mao Anjia,Guo Zhizhong.A practical placement of PMU in WAMS complemental to SCADA and data processing method[J].Power System Technology,2005,29(8):71-74(in Chinese).
|
[15] | Damborg M J,Kim M,Huang J,et al.Adaptive protection as preventive and emergency control[C].IEEE Power Engineering Society Summer Meeting,2000,2:1208-1212.
|
[16] | 王英涛,印永华,蒋宜国,等.我国实时动态监测系统的发展现状及实施策略研究[J].电网技术,2005,29(11):44-48.
|
[17] | 许树楷,谢小荣,辛耀中.基于同步相量测量技术的广域测量系统应用现状及发展前景[J].电网技术,2005,29(2):45-49.
|
[18] | Xu Shukai,Xie Xiaorong,Xin Yaozhong.Present application situation and development tendency of synchronous phasor measurement technology based wide area measurement system [J].Power System Technology,2005,29(2):45-49(in Chinese).
|
[19] | 李丹,韩福坤,郭子明,等.华北电网广域实时动态监测系统[J].电网技术,2004,28(23):52-56.
|
[20] | Li Dan,Han Fukun,Guo Ziming,et al.Wide-area real time dynamic security monitoring system of North China power grid[J].Power System Technology,2004,28(23):52-56(in Chinese).
|
[21] | 熊小伏,周家启,赵霞,等.快速后备保护研究[J].电力系统自动化,2003,27(11):45-47.
|
[22] | Xiong Xiaofu,Zhou Jiaqi,Zhao Xia,et al.Research on fast operating backup protection[J].Automation of Electric Power Systems,2003,27(11):45-47(in Chinese).
|
[23] | Tan J C,Crossley P A,Kirschen D,et al.An expert system for the back-up protection of a transmission network[J].IEEE Trans on Power Delivery,2000,15(2):508-514.
|
[24] | Tan J C,Crossley P A,Mclaren P G,et al.Sequential tripping strategy for a transmission network back-up protection expert system [J].IEEE Trans on Power Delivery,2002,17(1):68-74.
|
[25] | Serizawa Y,Myoujin M,Kitamura K,et al.Wide-area current
|
[26] | differential backup protection employing broadband communications and time transfer systems[J].IEEE Trans on Power Delivery,1998,13(4):1046-1052.
|
[27] | Serizawa Y,Imamura H,Kiuchi M.Performance evaluation of ip-based relay communications for wide-area protection employing external time synchronization[C].IEEE Power Engineering Society Summer Meeting,2001,2:909-914.
|
[28] | Kangvansaichol K,Crossley P A.Multi-zone differential protection for transmission networks[C].Eighth IEE International Conference on Developments in Power System Protection,2004,2:428-431.
|
[29] | 邱关源.电路(下册)[M].北京:高等教育出版社,1989.
|
[30] | 张保会.加强继电保护与紧急控制系统的研究提高互联电网安全防御能力[J].中国电机工程学报,2004,24(7):1-6.
|
[31] | Zhao Baohui.Strengthen the protection relay and urgency control system to improve the capability of security in the interconnected power network[J].Proceedings of the CSEE,2004,24(7):1-6(in Chinese).
|
[32] | 丛伟,潘贞存,丁磊,等.满足“三道防线”要求的广域保护系统及其在电力系统中的应用[J].电网技术,2004,28(18):29-33.
|
[33] | Cong Wei,Pan Zhencun,Ding Lei,et al.Wide area protection system to defend three different types of power system stability problems and its application[J].Power System Technology,2004,28(18):29-33(in Chinese).
|