电网技术  2009 

新型串联型电压跌落补偿装置的直流母线电压控制

, PP. 50-54

Keywords: 电压跌落,电能质量,串联补偿,补偿深度,直流母线电压

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对电网电压跌落问题,提出一种无变压器、无储能电容的串联型电压跌落补偿装置。为了克服该装置直流母线电压过高,因而对逆变器开关管耐压要求过高的缺点,提出一种对直流母线电压进行控制的方法。对全控型开关器件设计一种特殊的控制逻辑,使其等效为一个自然导通、触发关断的半控型开关器件,将该半控型开关串联在直流母线上,有效解决了直流母线电压过高的问题。实验结果验证了所提出方案的正确性和有效性。

References

[1]  王宾,潘贞存,徐丙垠.配电系统电压跌落问题的分析[J].电网技术,2004,28(2):56-59.
[2]  Wang Bin,Pan Zhencun,Xu Bingyin.Analysis of voltage sags in distribution system[J].Power System Technology,2004,28(2):56-59(in Chinese).
[3]  罗卫华,孙云莲.独立分量分析法在电能质量监测与分析中的应用[J].电网技术,2006,30(15):81-84,89.
[4]  Luo Weihua,Sun Yunlian.Application of independent component analysis in monitoring and analysis of power quality[J].Power System Technology,2006,30(15):81-84,89(in Chinese).
[5]  Zhu Guiping,Wang Shumin.A survey on power quality control technology[J].Automation of Electric Power Systems,2002,26(19):28-31(in Chinese).
[6]  Hyosung K.Minimal energy control for a dynamic voltage restorer [C].Proceedings of the Power Conversion Conference,Osaka,2002.
[7]  王宾,潘贞存,董新洲.电压跌落的配电线路全线速切治理方案[J].电网技术,2006,30(21):84-88.
[8]  Wang Bin,Pan Zhencun,Dong Xinzhou.A scheme of the fast tripping current protection for distribution lines based on the voltage sag mitigation[J].Power System Technology,2006,30(21):84-88(in Chinese).
[9]  袁佳歆,陈柏超,万黎,等.利用配电网静止无功补偿器改善配电网电能质量的方法[J].电网技术,2004,28(19):81-84.
[10]  Yuan Jiaxin,Chen Baichao,Wan Li,et al.The method to improve power quality of distribution system by distribution static compensator [J].Power System Technology,2004,28(19):81-84(in Chinese).
[11]  黄瀚,杨潮,韩英铎,等.配电网动态电压调节器控制策略的研究[J].电网技术,2002,26(1):1-4.
[12]  Huang Han,Yang Chao,Han Yingduo,et al.Study on control strategy of dynamic voltage restorer for distribution network [J].Power System Technology,2002,26(1):1-4(in Chinese).
[13]  Chen P T,Huang C C,Pan C C.Design and implementation of a series voltage sag compensator under practical utility conditions [J].IEEE Trans on Industry Applications,2003,39(3):844-853.
[14]  Conroy E.Power monitoring and harmonic problem in the modern building[J].IEEE Power Engineering,2001,15(2):101-107.
[15]  Vilathgamuwa M,Ranjith Perera A A D,Choi S S,et al.Control of energy optimized dynamic voltage restorer[C].The 25th Annual Conference of the IEEE Industrial Electronics Society,California,USA,1999.
[16]  Hosseini S H,Banael M R.A new minimal energy control of the DC link energy in four-wire dynamic voltage restorer[C].The 30th Annual Conference of the IEEE Industrial Electronics Society,South Korea,2004.
[17]  Visser A J,Enslin J H R,de T Mouton H.Transformerless series sag compensation with a cascaded multilevel inverter[J].IEEE Trans on Industry Electronics,2002,4(9):824-831.
[18]  Brumsickle W E,Schneider R S,Luckjiff G A,et al.Dynamic sag correctors: cost-effective industrial power line conditioning[J].IEEE Trans on Industry Applications,2001,37(1):212-217.
[19]  Chen Zenglu,Toshifimi I S E.Transformerless series: voltage sag compensator without energy storage capacitor for three-phase three line systems[J].電気学会論文誌D,2007,127(7):693-700.
[20]  詹佩,陈增禄,姚伟鹏,等.一种无变压器无储能电容的串联型电压跌落补偿装置实验研究[J].电网技术,2008,32(4):46-51.
[21]  Zhan Pei,Chen Zenglu,Yao Weipeng,et al.An experiment research on transformerless series voltage sag compensators without energy-storage capacitor[J].Power System Technology,2008,32(4):46-51(in Chinese).
[22]  陈增禄,姚伟鹏,毛惠丰,等.一种电压暂变发生器研究[J].电力电子技术,2007,41(3):97-99.
[23]  Chen Zenglu,Yao Weipeng,Mao Huifeng,et al.Research on a kind of voltage transients generator[J].Power Electronics,2007,41(3):97-99(in Chinese).
[24]  王宾,潘贞存,徐文远.配电系统电压跌落幅值估算分析[J].中国电机工程学报,2005,25(13):29-34.
[25]  Wang Bin,Pan Zhencun,Xu Wenyuan.Voltage sags profile estimation for power distribution systems[J].Proceedings of the CSEE,2005,25(13):29-34(in Chinese).
[26]  赵剑锋,王浔,潘诗锋.用电设备电能质量敏感度测试系统研究[J].中国电机工程学报,2005,25(22):32-37.
[27]  Zhao Jianfeng,Wang Xun,Pan Shifeng.Study on power quality susceptivity testing system of ac contactor[J].Proceedings of the CSEE,2005,25(22):32-37(in Chinese).
[28]  王松岑,于坤山,汤广福.动态电压恢复器数字矢量控制方法的性能分析及改进[J].中国电机工程学报,2008,28(7):64-71.
[29]  Wang Songcen,Yu Kunshan,Tang Guangfu.Performance analysis and improvement of digital vector control algorithm for dynamic voltage restorer[J].Proceedings of the CSEE,2008,28(7):64-71(in Chinese).
[30]  袁川,杨洪耕.动态电压恢复器的改进最小能量控制[J].电力系统自动化,2004,28(21):49-53.
[31]  Yuan Chuan,Yang Honggeng.Advanced minimum energy control of dynamic voltage restorer[J].Automation of Electric Power Systems,2004,28(21):49-53(in Chinese).
[32]  张迪,姜齐荣,张秀娟.动态电压恢复器的能量稳定控制[J].电网技术,2006,30(1):14-18.
[33]  Zhang Di,Jiang Qirong,Zhang Xiujuan.Energy steady control for dynamic voltage restorer[J].Power System Technology,2006,30(1):14-18(in Chinese).
[34]  朱桂萍,王树民.电能质量控制技术综述[J].电力系统自动化,2002,26(19):28-31.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133