电网技术  2010 

输电铁塔冷弯角钢构件轴心受压承载力分析及试验研究

, PP. 194-199

Full-Text   Cite this paper   Add to My Lib

Abstract:

在输电线路铁塔应用冷弯型钢,可以提高我国输电铁塔设计水平,降低钢材用量。结合输电铁塔的结构特点,选取不同截面、不同长细比的冷弯角钢构件进行轴心受压承载力试验和有限元分析,得到了输电铁塔用冷弯角钢轴心受压构件的荷载—应变发展规律和极限承载力,并与现行设计规范承载力计算值进行对比。分析结果表明,现行规范体系不适合我国输电铁塔冷弯型钢轴心受压构件的强度设计。通过对试验和理论分析结果进行拟合,确定了输电铁塔冷弯型钢轴心受压构件稳定系数曲线,提出了输电铁塔冷弯型钢构件承载力计算的修正意见,为冷弯型钢在我国输电铁塔中的应用提供了参考和依据。

References

[1]  Ben Y,Ehab E.Buckling analysis of cold- formed steel lipped angle columns[J].Journal of Structural Engineering,1999,131(10):1570-1579.
[2]  Ben Y.Experimental investigation of cold-formed steel lipped angle concentrically loaded compression members[J].Journal of Structural Engineering,2005,131(9):1390-1396.
[3]  Popovic D,Hancock G J,Rasmussen K J R. Axial compression tests of cold-formed angles[J].Journal of Structural Engineering,1999,125(5):515-523.
[4]  ASCE110—97,Design of latticed steel transmission structures[S].
[5]  DL/T 5154—2002,架空送电线路杆塔结构设计技术规定[S].
[6]  杨靖波,李茂华,杨风利,等.我国输电线路杆塔结构研究新进展[J].电网技术,2008,32(22):77-83. Yang Jingbo,Li Maohua,Yang Fengli,et al.New advances in the study of transmission tower structure of China[J].Power System Technology,2008,32(22):77-83(in Chinese).
[7]  李正良,刘红军,张东英,等.Q460高强钢在1000kV杆塔的应用[J].电网技术,2008,32(24):1-5. Li Zhengliang,Liu Hongjun,Zhang Dongying,et al.Application of high-strength steel Q460 in 1 000 kV transmission towers[J].Power System Technology,2008,32(24):1-5(in Chinese).
[8]  李茂华,李正,任吉华,等.500 kV输电线路杆塔结构的可靠性分析[J].电网技术,2008,32(23):91-94. Li Maohua,Li Zheng,Ren Jihua,et al.Reliability analysis on tower structure for 500 kV transmission lines[J].Power System Technology,2008,32(23):91-94(in Chinese).
[9]  郭日彩,许子智,李喜来,等.110~500 kV输电线路典型设计[J].电网技术,2007,31(1):56-64. Guo Ricai,Xu Zizhi,Li Xilai,et al.Typical design of transmission lines within voltage grades from 110 kV to 500 kV and its application[J].Power System Technology,2007,31(1):56-64(in Chinese).
[10]  GB 50018—2002,冷弯薄壁型钢结构技术规定[S].
[11]  何长华.高强冷弯型钢在输电铁塔上应用可行性的探讨[J].特种钢结构,2004,19(5):35-37. He Changhua.Feasibility discussion on application of high strength cold-formed section steel in transmission tower[J].Steel Construction, 2004,19(5):35-37 (in Chinese).
[12]  Mohan S J,Shabeen S R,Knight G M S.Behavior of cold formed lipped angles in transmission line towers[J].Thin-Walled Structures, 2006(44):1017-1030.
[13]  Ben Y,Kim J R R.Behavior of cold-formed singly symmetric columns[J].Thin-Walled Structures,1999(33):83-102.
[14]  薄壁型钢结构技术规范编写组.冷弯薄壁型钢轴心受压构件的稳定性计算[J].建筑结构学报,1991,12(4):1-10. Revision Group of the Specification for Design of Thin-walled Steel Structures.Calculation of stability of axially loaded compression members made of cold-formed thin-walled steel sections[J].Journal of Building Engineering,1991,12(4):1-10(in Chinese).
[15]  国网北京电力建设研究院.耐候钢及冷弯型钢在输电铁塔中的应用研究[R].北京:国网北京电力建设研究院,2007.