全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
电网技术  2014 

变压器油中糠醛浓缩萃取新技术

DOI: 10.13335/j.1000-3673.pst.2014.05.041, PP. 1390-1395

Keywords: 糠醛检测,萃取,浓缩,变压器油,老化分析

Full-Text   Cite this paper   Add to My Lib

Abstract:

变压器油中的糠醛含量是电力变压器固体绝缘老化的重要判据之一,但由于变压器油中糠醛浓度过低,给检测工作带来了极大困难。设计了一种新的变压器油中糠醛萃取方法,并在该方法的基础上提出了2种浓缩变压器油中糠醛的方案一种为通过改变萃取液与油样的比值,从而达到浓缩效果的方法;另一种为通过多次萃取达到浓缩效果的方法。实验结果表明第1种方法操作简单,萃取时间短,能有效降低操作误差的影响,但在要求高倍浓缩的情况下,萃取效率较低,浓缩效果有限;第2种方法虽然萃取时间较长,但萃取效率高,可达90%以上,浓缩效果好,能够实现所希望的浓缩率,因此,更能满足对变压器油中低浓度糠醛分析的精度要求。

References

[1]  周远翔,沙彦超,陈维江,等.变压器油与绝缘纸板电导特性研究[J].电网技术,2013,39(9):2527-2533. Zhao Yuanxiang,Sha Yanchao,Chen Weijiang,et a1.Conduction characteristics in transformer oil and electrical insulation paper[J].Power System Technology,2013,39(9):2527-2533(in Chinese).
[2]  Shkolnik A B,Bilgin K M,Kelly J J. Creating a preliminary model for estimating degree of polymerization of thermally upgraded insulating paper based on furan concentrations in transformer oil[C]//Minutes of the Sixty Sixth Annual International Conference of Doble Clients. 1999:5-8.
[3]  中华人民共和国国家发展和改革委员会.DL/T 984—2005 油浸式变压器绝缘老化判断导则[S].北京:中国电力出版社,2005.
[4]  马利花,刘英,王毅,等.高效液相色谱测定变压器油糠醛含量的方法及其影响因素[J].润滑油,2012,27(5):55-59. Ma Lihua,Liu Ying,Wang Yi,et a1.Determination of furfural content in transformer oil by HPLC and analysis of its influencing factors[J].Lubricating Oil,2012,27(5):55-59(in Chinese).
[5]  Saha T K.Review of modern diagnostic techniques for assessing insulation condition in aged transformers[J].IEEE Trans on Dielectrics and Electrical Insulation,2003,10(5):903-917.
[6]  国际电工委员会.IEC 61198—1993矿物绝缘油 2:糠醛及相关化合物的测定方法[S].北京:中国电力出版社,1993.
[7]  卢立秋,郭军科,刘鸿芳.变压器油中的糠醛萃取新技术[J].宁夏电力,2011(6):44-45,56. Lu Liqiu,Guo Junke,Liu Hongfang.New technology of furfural extraction in transformer oil[J].Ningxia Electric Power,2011(6):44-45,56(in Chinese).
[8]  张欲晓,李胜利,王梦君,等.变压器绝缘纸的聚合度变化规律[J].高电压技术,2011,37(10):2458-2463. Zhang Yuxiao,Li Shengli,Wang Mengjun,et a1.Degree of polymerization of insulation paper in the transformer[J].High Voltage Engineering,2011,37(10):2458-2463(in Chinese).
[9]  Oommen T V, Claiborne C C, Walsh E J, et al. A new vegetable oil based transformer fluid: development and verification[C]//Electrical Insulation and Dielectric Phenomena, 2000 Annual Report Conference on. IEEE,2000,1: 308-312.
[10]  王伟,曲文韬,杨承龙,等.油浸式电力变压器固体绝缘老化检测技术的应用[J].电气技术,2010(10):39-42. Wang Wei,Qu Wentao,Yang Chenglong,et a1.Application of detection technique for solid insulation aging in oil-immersed power transformer[J].Electrical Engineering,2010(10):39-42(in Chinese).
[11]  Oommen T V.Vegetable oils for liquid-filled transformers[J].IEEE Electrical Insulation Magazine,2002,18(1):6-11.
[12]  朱德恒.电绝缘诊断技术[M].北京:中国电力出版社,1999:4-10.
[13]  郝建,廖瑞金,杨丽君,等.应用频域介电谱法的变压器油纸绝缘老化状态评估[J].电网技术,2011,35(7):187-193. He Jian,Liao Ruijin,Yang Lijun,et a1.Aging status assessment of power transformer oil-paper insulation by frequency-domain dielectric spectroscopy [J].Power System Technology,2011, 35(7):187-193(in Chinese).
[14]  孙才新,陈伟根,李俭,等.电气设备油中气体在线监测与故障诊断技术[M].北京:科学出版社,2003:27-31.
[15]  徐志强,刘阳,赵敏乔,等.油中糠醛浓度判定变压器固体绝缘劣化程度的研究[J].电子建设,2010,2(2):36-38. Xu Zhiqiang,Liu Yang,Zhao Minqiao,et a1.Study on furfural concentration to judge transformer solid insulation deterioration degree[J].Electric Power Construction,2010,2(2):36-38(in Chinese).
[16]  沈一平,郑德富.糠醛浓度分析在电力变压器固体绝缘老化诊断中的应用[J].高压电器,2008,44(1):84-86. Shen Yipin,Zheng Defu.Application of furfural content analysis to diagnosis of solid insulation ageing in power transformers[J].High Voltage Apparatus,2008,44(1):84-86(in Chinese).
[17]  IEC 1198—1993.Mineral insulating oils-methods for the determination of 2-furfrual and related compounds[S].
[18]  中华人民共和国电力工业部.DL/T 596—1996 电力设备预防性试验规程[S].北京:中国电力出版社,2009.