电网技术  2014 

带并联电抗器同杆双回线跨线故障性质判别方法

DOI: 10.13335/j.1000-3673.pst.2014.07.044, PP. 2001-2007

Keywords: 同杆双回线,跨线故障,故障性质,模电压

Full-Text   Cite this paper   Add to My Lib

Abstract:

针对带并联电抗器的同杆双回线线路,在复频域上对故障相端电压进行详细分析,提出利用故障相β模电压进行故障性质判断的方法,其中β模电压为不同回线故障相电压平均值之差。以IABIIBC跨线故障为例进行仿真分析,综合得出利用故障相β模电压进行判断的结论,并给出了不同故障类型下的β模电压求解通式。瞬时性跨线故障下β模电压中既存在工频分量又存在自由频率分量;而永久性跨线故障下β模电压中只存在工频分量。通过利用最小二乘法提取其中自由频率分量幅值可以准确判断出故障性质,原理简单,灵敏度高。大量ATP仿真实验表明,该方法能够识别不同跨线故障类型的故障性质,可以应用于带并联电抗器同杆双回线的自适应重合闸。

References

[1]  李博通,李永丽.基于故障点电压特性的同杆双回线自适应重合闸[J].电力系统保护与控制,2012,40(11):46-54. Li Botong,Li Yongli.An adaptive autoreclosure technique for double-circuit transmission line based on voltage characteristics at fault point[J].Power System Protection and Control,2012,40(11):46-54(in Chinese).
[2]  李永丽,李博通.带并联电抗器输电线路三相永久性和瞬时性故障的判别方法[J].中国电机工程学报,2010,30(1):82-90. Li Yongli,Li Botong.Identification of three-phase permanent or temporary fault at transmission lines with shunt reactors[J].Proceedings of the CSEE,2010,30(1):82-90(in Chinese)
[3]  Christos A,George N.A novel fault-location algorithm for double-circuit transmission lines without utilizing line parameters[J].IEEE Trans on Power Delivery,2011,26(3):1467-1478.
[4]  刘玉萍,何正友,何文.基于线路参数修正的同杆双回线故障定位方法[J].电网技术,2012,36(5):96-101. Liu Yuping,He Zhengyou,He Wen.Fault location for double-circuit transmission lines on same tower based on modification of transmission line parameters[J].Power System Technology,2012,36(5):96-101(in Chinese).
[5]  Wei Li,Xu Zhenyu,Yang Qixun.First-zone distance relaying algorithm of parallel transmission lines for cross-country grounded faults[J].IEEE Trans on Power Delivery,2012,27(4):2185-2192.
[6]  吴麟琳,黄少锋.平行双回线对反时限零序电流保护的影响及改进算法[J].电网技术,2013,37(3):707-712. Wu Linlin,Huang Shaofeng.Influence of Parallel double-circuit transmission lines on inverse-time zero-sequence current protection and its improved algorithm[J].Power System Technology,2013,37(3):707-712(in Chinese).
[7]  宋国兵,索南加乐,孙丹丹.输电线路永久性故障判别方法综述[J].电网技术,2006,30(18):75-80. Song Guobing,Suonan Jiale,Sun Dandan.A survey on methods to distinguish permanent faults from instantaneous faults in transmission lines[J].Power System Technology,2006,30(18):75-80(in Chinese).
[8]  李炜,陈剑,姜美玲,等.考虑电容电流的同塔双回线接地距离保护零序电流补偿系数的整定[J].电网技术,2012,36(7):281-284. Li Wei,Chen Jian,Jiang Meiling,et al.Setting of zero-sequence current compensation coefficient for ground distance relays of double-circuit transmission lines on same tower considering capacitive current[J].Power System Technology,2012,36(7):281-284(in Chinese).
[9]  周春霞,余越,赵寒,等.特高压同塔双回线路零序电流补偿系数整定对接地距离保护的影响研究[J].电网技术,2012,36(12):106-111. Zhou Chunxia,Yu Yue,Zhao Han,et al.Influence of zero-sequence current compensation coefficient setting on earth-fault distance protection for double circuit UHVAC transmission lines on the same tower[J].Power System Technology,2012,36(12):106-111(in Chinese).
[10]  刘浩芳,王增平,徐岩,等.带并联电抗器的超/特高压输电线路相自适应重合闸故障性质识别判据[J].电网技术,2006,30(18):29-34. Liu Haofang,Wang Zengping,Xu Yan,et al.Criterion for determining fault nature in adaptive single-phase reclosing for shunt compensated EHV/UHV transmission lines[J].Power System Technology,2006,30(18):29-34(in Chinese).
[11]  索南加乐,邵文权,宋国兵.基于参数识别的单相自适应重合闸研究[J].中国电机工程学报,2009,29(1):48-54. Suonan Jiale,Shao Wenquan,Song Guobing.Study on single-phase adaptive reclosure scheme based on parameter identification[J].Proceedings of the CSEE,2009,29(1):48-54(in Chinese).
[12]  王增平,刘浩芳,徐岩,等.基于改进型相关法的单相自适应重合闸新判据[J].中国电机工程学报,2007,27(10):49-55. Wang Zengping,Liu Haofang,Xu Yan,et al.A new criterion for single-phase adaptive automatic reclosure based on improved correlation algorithm[J].Proceedings of the CSEE,2007,27(10):49-55(in Chinese).
[13]  Lin Xiangning,Liu Haifeng,Weng Hanli,et al.A dual-window transient energy ratio-based adaptive single-phase reclosure criterion for EHV transmission line[J].IEEE Trans on Power Delivery,2007, 22(4):2080-2086.
[14]  林达,王慧芳,何奔腾,等.基于波形相关性的带并联电抗器线路永久性故障判别方法[J].电力系统自动化,2013,37(16):80-84. Lin Da,Wang Huifang,He Benteng,et al.Identification of permanent fault at transmission lines with shunt reactors based on waveform correlation[J].Automation of Electric Power Systems,2013,37(16):80-84(in Chinese).
[15]  刘玉,文俊,肖湘宁.特高压线路单相自适应重合闸仿真分析[J].电网技术,2010,34(3):11-15. Liu Yu,Wen Jun,Xiao Xiangning.Simulation analysis on single-phase adaptive autoreclosure of UHV transmission line[J].Power System Technology,2010,34(3):11-15(in Chinese).
[16]  刘俊岭,刘汉青,刘浩芳.基于准测距结果的输电线单相故障性质识别[J].电网技术,2009,33(8):84-86. Liu Junling,Liu Hanqing,Liu Haofang.Single-phase fault feature recognition of transmission line based on quasi fault location[J].Power System Technology,2009,33(8):84-86(in Chinese).
[17]  朱建红,陈福峰,魏曜,等.新型同杆双回线自适应重合闸方案研究[J].电力自动化设备,2007,27(4):47-51. Zhu Jianhong,Chen Fufeng,Wei Yao,et al.Study of self-adaptive reclosing for parallel lines[J].Electric Power Automation Equipment,2007,27(4):47-51(in Chinese).
[18]  郑玉平,黄震,张哲,等.同杆并架双回线自适应重合闸的研究[J].电力系统自动化,2004,28(22):58-62. Zheng Yuping,Huang Zhen,Zhang Zhe,et al.Study on adaptive auto-reclosing for parallel transmission lines [J].Automation of Electric Power Systems,2004,28(22):58-62(in Chinese).
[19]  刘毅,张哲,尹项根,等.同杆并架双回线自适应重合闸组合判据[J].电力系统自动化,2011,35(2):56-61. Liu Yi,Zhang Zhe,Yin Xianggen,et al.An combination criterion on adaptive reclosure for double transmission lines[J].Automation of Electric Power Systems,2011,35(2):56-61(in Chinese).
[20]  李博通,李永丽.同杆双回线跨线永久性故障识别方法[J].电力系统自动化,2012,36(3):87-91. Li Botong,Li Yongli.Method for identifying permanent cross-ling fault of double-circuit transmission line on the same tower[J].Automation of Electric Power Systems,2012,36(3):87-91(in Chinese).

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133