电网技术  2014 

局部阴影下光伏阵列全局最大功率点跟踪控制方法综述

DOI: 10.13335/j.1000-3673.pst.2014.12.002, PP. 3279-3285

Keywords: 局部阴影,全局最大功率点跟踪,阵列结构,采样数据,现代控制理论

Full-Text   Cite this paper   Add to My Lib

Abstract:

介绍了局部阴影下光伏阵列输出特性及最大功率点跟踪原理,对现有全局最大功率点跟踪控制方法从基于阵列硬件结构、采样数据、现代控制理论及其它等4方面进行分类与总结,对局部阴影下全局最大功率点跟踪还需关注的问题与未来全局最大功率点跟踪技术的发展方向进行了探讨。

References

[1]  Zainal S,Jubaer A,Benny S M.The application of soft computing methods for MPPT of PV system:a technological and status review[J].Applied Energy,2013(107):135-148.
[2]  Kashif I,Zainal S.A review of maximum power point tracking techniques of PV system for uniform insolation and partial shading condition[J].Renewable and Sustainable Energy Reviews,2013(19):475-488.
[3]  Mohamed A E,Zhao Zhengming.MPPT techniques for photovoltaic applications[J].Renewable and Sustainable Energy Reviews,2013(25):793-813.
[4]  De Brito M A G,Galotto L,Sampaio L P,et al.Evaluation of the main MPPT techniques for photovoltaic applications[J].IEEE Transactions on Industrial Electronics,2013,60(3):1156-1167.
[5]  Subudhi B,Pradhan R.A comparative study on maximum power point tracking techniques for photovoltaic power systems[J].IEEE Transactions on Sustainable Energy,2013,4(1):89-98.
[6]  Ali R R,Mohammad H M,Shahriar J.Classification and comparison of maximum power point tracking techniques for photovoltaic system:a review[J].Renewable and Sustainable Energy Reviews,2013(19):433-443.
[7]  胡义华.小型光伏系统及其关健问题研究[D].徐州:中国矿业大学,2011.
[8]  朱艳伟.光伏发电系统效率提高理论方法及关健技术研究[D].北京:华北电力大学,2012.
[9]  Noguchi T,Togashi S,Nakamoto R.Short-current pulse-based maximum power point tracking method for multiple photovoltaic and converter module system[J].IEEE Transactions on Industrial Electronics,2002,49(1):217-223.
[10]  Mishima T,Ohnishi T.Power compensation system for partially shaded PV array using electric double layer capacitors[C]//IEEE Annual Conference on Industrial Electronics Society.Spain:IEEE,2002:3262-3267.
[11]  Solodovnik E V,Liu S,Dougal R A.Power controller design for maximum power tracking in solar installations[J].IEEE Transactions on Power Electronics,2004,19(5):1295-1304.
[12]  Karatepe E,Boztepe M,Colak M.Development of a suitable model for characterizing photovoltaic arrays with shaded solar cells[J].Solar Energy,2007,81(8):977-992.
[13]  Karatepe E,Syafaruddin,Hyama T.Simple and high-efficiency photovoltaic system under non-uniform operating condition[J].IET Renewable Power Generation,2009,4(4):354-368.
[14]  Villa L F L,Picault D,Raison B, et al.Maximizing the power output of partially shaded photovoltaic plants through optimization of the interconnections among its modules[J].IEEE Journal of Photovoltaics,2012,2(2):154-163.
[15]  Wang Y J,Hsu P C.An investigation of partial shading of PV modules with different connection configurations of PV cells[J].Energy ,2011,36(5):3069-3078.
[16]  Gao L,Dougal R A,Liu S,et al.Parallel-connected solar PV system to address partial and rapidly fluctuating shadow conditions[J].IEEE Transactions on Industrial Electronics,2009,56(5):1548-1556.
[17]  Nguyen D,Lehman B.An adaptive solar photovoltaic array using model-based reconfiguration algorithm[J].IEEE Transactions on Industrial Electronics,2008,55(7):2644-2654.
[18]  Velasco-Quesada G,Guinjoan-Gispert F,Pique-Lopez R,et al.Electrical PV array reconfiguration strategy for energy extraction improvement in grid-connected PV systems[J].IEEE Transactions on Industrial Electronics,2009,56(11):4319-4331.
[19]  Villa L F L,Ho T P,Crebier J C,et al.A power electronics equalizer application for partially shaded photovoltaic modules[J].IEEE Transactions on Industrial Electronics,2013,60(3):1179-1190.
[20]  Gules R,Pacheco J D P,Hey H L,et al.A maximum power point tracking system with parallel connection for PV stand-alone applications[J].IEEE Transactions on Industrial Electronics,2008,55(7):2674-2683.
[21]  Femia N,Lisi G,Petrone G,et al.Distributed maximum power point tracking of photovoltaic arrays:novel approach and system analysis[J].IEEE Transactions on Industrial Electronics,2008,55(7):2610-2621.
[22]  Petrone G,Spagnuolo G,Vitelli M.An analog technique for distributed MPPT PV applications[J].IEEE Transactions on Industrial Electronics,2012,59(12):4713-4722.
[23]  Linares L,Erickson R W,MacAlpine S,et al.Improved energy capture in series string photovoltaics via smart distributed power electronics
[24]  [C]//IEEE Applied Power Electronics Conference and Exposition24 (APEC).DC:IEEE,2009:904-910.
[25]  Chong B V P,Zhang L.Controller design for integrated PV:converter modules under partial shading conditions[J].Solar Energy,2013(92):123-138.
[26]  Kobayashi K,Takano I,Sawada Y.A study of a two stage maximum power point tracking control of a photovoltaic system under partially shaded insolation conditions[J].Solar Energy Materials and Solar Cells,2006,90 (18-19):2975-2988.
[27]  Ji Y H,Jung D Y,Kim J G,et al.A real maximum power point tracking method for mismatching compensation in PV array under partially shaded conditions[J].IEEE Transactions on Power Electronics,2011,26(4):1001-1009.
[28]  Punitha K,Devaraj D,Sakthivel S.Artificial neural network based modified incremental conductance algorithm for maximum power point tracking in photovoltaic system under partial shading conditions
[29]  [J].Energy,2013(62):330-340.
[30]  Hiren P,Vivek A.Maximum Power Point Tracking Scheme for PV Systems Operating Under Partially Shaded Conditions[J].IEEE Transactions on Industrial Electronics,2008,55(4):1689-1698.
[31]  Chin C S,Tan M K,Neelakantan P.Optimization of partially shaded PV array using fuzzy MPPT[J].IEEE Colloquium on Humanities Science and Engineering (CHUSER),2011:481-486.
[32]  Chin C S,Neelakantan P,Yoong H P,et al.Maximum power point tracking for PV array under partially shaded condition[C] //
[33]  International Conference on Computational Intelligence,Communication Systems and Networks (CICSyN).Balic,2011:72-77.
[34]  Ishaque K,Salam Z,Shamsudin A,et al.A direct control based maximum power point tracking method for photovoltaic system under partial shading conditions using particle swarm optimization algorithm[J].Applied Energy,2012(99):414-422.
[35]  Ishaque K,Salam Z,Amjad M,et al.An improved particle swarm optimization (PSO)-based MPPT for PV with reduced steady state oscillation[J].IEEE Transactions on Power Electronics,2012(27):3627-3638.
[36]  朱艳伟,石新春,但扬清,等.粒子群优化算法在光伏阵列多峰最大功率点跟踪中的应用[J].中国电机工程学报,2012,32(4):42-48. Zhu Yanwei,Shi Xinchun,Dan Yangqing,et al.Application of PSO algorithm in global MPPT for PV array[J].Proceedings of the CSEE,2012,32(4):42-48(in Chinese).
[37]  Liu Y,Xia D,He Z.MPPT of a PV system based on the particle swarm optimization[C]//International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).Shandong:IEEE,2011:1094-1096.
[38]  Phimmasone V,Endo T,Kondo Y,et al.Improvement of the maximum power point tracker for photovoltaic generators with particle swarm optimization technique by adding repulsive force among agents[C]//International Conference on Electrical Machines and Systems(ICEMS).Tokyo:IEEE,2009:1-6.
[39]  Phimmasone V,Kondo Y,Kamejima T,et al.Evaluation of extracted energy from PV with PSO-based MPPT against various types of solarirradiation changes[C]//International Conference on Electrical Machines and Systems(ICEMS).Incheon:IEEE,2010:487-492.
[40]  Ishaque K,Salam Z.A deterministic particle swarm optimization maximum power point tracker for photovoltaic system under partial shading condition[J].IEEE Transactions on Industrial Electronics,2013,60(8):3195-3206.
[41]  Roy C S,Saha H.Maximum power point tracking of partially shaded solar photovoltaic arrays[J].Solar Energy Materials and Solar Cells,2010(94):1441-1447.
[42]  Miyatake M,Toriumi F,Endo T,et al.Maximum power point tracking of multiple photovoltaic arrays:a PSO approach[J].IEEE Transactions Aerospace and Electronic Systems,2011,47(1):367-380.
[43]  Letting L K,Munda J L,Hamam Y.Optimization of a fuzzy logic controller for PV grid inverter control using S-function based PSO[J].Solar Energy,2012,86(6):1689-1700.
[44]  Jiang L L,Douglas L M,Jagdish C.A novel ant colony optimization-based maximum power point tracking for photovoltaic systems under partially shaded conditions[J].Energy and Buildings,2013(58):227-236.
[45]  Adly M,Besheer A H.An Optimized Fuzzy Maximum Power Point Tracker for Stand Alone Photovoltaic Systems: Ant Colony Approach
[46]  [C]//IEEE Conference on Industrial Electronics and Applications (ICIEA).Singapore:IEEE,2012:113-119.
[47]  Besheer A H,Adly M.Ant colony system based PI maximum power point tracking for stand alone photovoltaic system[C]//IEEE International Conference on Industrial Technology (ICIT).Athens:IEEE,2012:693-698.
[48]  Yousra S,Mouna B S,Anis S,et al.Comparison between conventional methods and GA approach for maximum power point tracking of shaded solar PV generators[J].Solar Energy,2013(90):107-122.
[49]  崔岩,白静晶.光伏阵列多峰最大功率点跟踪研究[J].电机与控制学报,2012,16(6):87-91. Cui Yan,Bai Jingjing.Research on multi-peak PV module maximum power point tracking[J].Eletric Machines and Control,2012,16(6):87-91(in Chinese).
[50]  Ramaprabha R,Gothandaraman V,Kanimozhi K,et al.Maximum power point tracking using GA-optimized artificial neural network for Solar PV system[C]//International Conference on Electrical Energy Systems (ICEES).CA:IEEE,2011:264-268.
[51]  Tajuddin M F N,Ayob S M,Salam Z.Tracking of Maximum Power Point in Partial Shading Condition using Differential Evolution (DE)[C]//IEEE International Conference on Power and Energy.Kota Kinabalu:IEEE,2012:384-389.
[52]  Taheri H,Salam Z,Ishaque K,et al.A novel maximum power point tracking control of photovoltaic system under partial and rapidly fluctuating shadow conditions using differential evolution[C]//IEEE Symposium on Industrial Electronics & Applications (ISIEA).Penang:IEEE,2010:82-87.
[53]  Taheri T S,Taheri H,Salam Z,et al.Modified maximum power point tracking (MPPT) of grid-connected PV system under partial shading conditions[C]//IEEE Canadian Conference on Electrical and Computer Engineering (CCECE).QC:IEEE,2012:1-4.
[54]  Mohammad F N T,Shahrin M A,Zainal S,et al.Evolutionary based maximum power point tracking technique using differential evolution algorithm[J].Energy and Buildings,2013(67):245-252.
[55]  Subiyanto,Mohamed A,Hopfield Shareef H.Hopfield neural network optimized fuzzy logic controller for maximum power point tracking in a photovoltaic system[C]//International Journal of Photoenergy.Selangor:National University of Malaysia,2012:6-13.
[56]  刘立群,王志新,张华强.部分遮蔽光伏发电系统模糊免疫MPPT控制[J].电力自动化设备,2010,30(7):96-99. Liu Liqun,Wang Zhixin ,Zhang Huaqiang.Fuzzy-immune MPPT control of PV generation system under partial shade condition [J].Electric Power Automation Equipment,2010,30(7):96-99(in Chinese).
[57]  Alajmi B N,Ahmed K H,Finney S J,et al.A maximum power point tracking technique for partially shaded photovoltaic systems in microgrids[J].IEEE Transactions on Industrial Electronics,2013,60(4):
[58]  Alajmi B N,Ahmed K H,Finney S J,et al.Fuzzy-logic-control approach of a modified Hill-climbing method for maximum power point in microgrid standalone photovoltaic system[J].IEEE Trans Power Electron,2011,26(3):1022-1030.
[59]  Syafaruddin E,Karatepe T H.Artificial neural network-polar coordinated fuzzy controller based maximum power point tracking control under partially shaded conditions[J].IET Renewable Power Generation,2008,3(2):239-253.
[60]  Zhou Lin,Chen Yan,Guo Ke,et al.New approach for MPPT control of photovoltaic system with mutative-scale dual-carrier chaotic search[J].IEEE Transactions on Power Electronics,2011,26(4): 1038-1048.
[61]  Ramaprabha R,Mathur B,Ravi A,et al.Modified Fibonacci search based MPPT scheme for SPVA under partial shaded conditions[C]//International Conference on Emerging Trends in Engineering and Technology (ICETET) .Goa:IEEE,2010:379-384.
[62]  Miyatake M,Inada T,Hiratsuka I,et al.Control characteristics of a Fibonacci-search-based maximum power point tracker when a photovoltaic array is partially shaded[C]//International Power Electronics and Motion Control Conference(IPEMC).Xi'an:IEEE,2004:816-821.
[63]  Nabil A A,Masafumi M.A novel maximum power point tracking for photovoltaic applications under partially shaded insolation conditions[J].Electric Power Systems Research,2008(78):777-784.
[64]  Ramaprabha R,Balaji M,Mathur B L.Maximum power point tracking of partially shaded solar PV system using modified Fibonacci search method with fuzzy controller[J].Electrical Power and Energy Systems,2012(43):754-765.
[65]  Tat L N, Low K S.A Global Maximum power point tracking scheme employing DIRECT search algorithm for photovoltaic systems
[66]  [C]//IEEE Transactions on Industrial Electronics,2010,57(10):3456-3467.
[67]  胡义华,陈昊,徐瑞东,等.阴影影响下最大功率点跟踪控制[J].中国电机工程学报,2012,32(9):14-26. Hu Yihua,Chen Hao,Xu Ruidong,et al.Maximum power point tracking under shadowed conditions[J].Proceedings of the CSEE,2012,32(9):14-26(in Chinese).
[68]  Boztepe M,Guinjoan F,Velasco-Quesada G,et al.Global MPPT scheme for photovoltaic string inverters based on restricted voltage window search algorithm[J].IEEE Transactions on Industrial Electronics,2013(99):1-11.
[69]  Alireza K,Hossein I E,Behzad A.A new maximum power point tracking strategy for PV arrays under uniform and non-uniform insolation conditions[J].Solar Energy,2013(91):221-232.
[70]  Lei Peng,Li Yaoyu,Seem J E.Sequential ESC-based global MPPT control for photovoltaic array with variable shading[J].IEEE Transactions on Sustainable Energy,2011,2(3):348-358.
[71]  Hamed H D,Reza K,Mohammad R K,et al.A new approach in MPPT for photovoltaic array based on extremum seeking control under uniform and non-uniform irradiances[J].Solar Energy,2013(94):28-36.
[72]  Koutroulis E,Blaabjerg F.A New Technique for Tracking the Global Maximum Power Point of PV Arrays Operating Under Partial Shading Conditions[J].IEEE Journal of Photovoltaics,2012,2(2):184-190.
[73]  Latham A M,Pilawa-Podgurski R,Odame K M,et al.Analysis and Optimization of Maximum Power Point Tracking Algorithms in the Presence of Noise[J].IEEE Transactions on Power Electronics,2013,28(7):3479-3494.
[74]  赵争鸣,陈剑.太阳能光伏发电最大功率点跟踪技术[M].北京:电子工业出版社,2012:21-26.

Full-Text

Contact Us

service@oalib.com

QQ:3279437679

WhatsApp +8615387084133