张文亮,谷琛,廖蔚明,等.超/特高压直流输电线路塔头间隙冲击放电特性研究[J].中国电机工程学报,2010,30(1):1-5.Zhang Wenliang,Gu Chen,Liao Weiming,et al.Impulse voltage flashover characteristic of air gap in EHV/UHV DC transmission tower[J].Proceedings of the CSEE,2010,30(1):1-5(in Chinese).
[2]
孙昭英,李斌.±500 kV直流输电线路杆塔空气间隙放电特性的研究[J].高电压技术,1986,12(1):14-18.Sun Zhaoying,Li Bin.Studies on the flashover characteristics of tower air clearances for ±500 kV HVDC transmission lines[J].High Voltage Engineering,1986,12(1):14-18(in Chinese).
[3]
赵林杰,黎小林,孙昭英,等.±500 kV同塔双回线路杆塔空气间隙操作冲击放电特性试验研究[J].南方电网技术,2011(2):26-29. Zhao Linjie,Li Xiaolin,Sun Zhaoying,et al.Experiment study on the characteristics of switching impulse flashover at air gaps on the tower with ±500 kV double-circuit lines[J].Southern Power System Technology,2011(2):26-29(in Chinese).
[4]
廖蔚明,丁玉剑,孙昭英,等.高压直流输电线路V型串塔头间隙操作冲击放电电压的海拔校正[J].电网技术,2012,36(1):182-187.Liao Weiming,Ding Yujian,Sun Zhaoying,et al.Altitude correction of switching impulse flashover voltage of tower gaps with V-shaped insulator strings for HVDC power transmission lines [J].Power System Technology,2012,36(1):182-187(in Chinese).
[5]
张文亮,廖蔚明,丁玉剑,等.不同海拔地区同塔双回±660 kV直流线路杆塔空气间隙距离的选择[J].中国电机工程学报,2008,28(34):1-6.Zhang Wenliang,Liao Weiming,Ding Yuian,et al.Selection of the minimum air clearance for ±660 kV double-circuit DC transmission line tower in different altitude areas[J].Proceedings of the CSEE,2008,28(34):1-6(in Chinese).
[6]
刘洪正,刘凯,孟海磊,等.±660 kV直流同塔双回输电线路带电作业试验研究[J].高电压技术,2011,37(12):2997-3005.Liu Hongzheng,Liu Kai,Meng Hailei,et al.Experimental research of live working on ±660 kV double circuit DC transmission line on the same tower[J].High Voltage Engineering,2011,37(12):2997-3005(in Chinese).
[7]
孙昭英,廖蔚明,丁玉剑,等.±800 kV直流输电工程空气间隙放电特性试验及间隙距离选择[J].电网技术,2008,32(22):8-12.Sun Zhaoying,Liao Weiming,Ding Yujian,et al.Air gap flashover characteristics and selection of gap distances for ±800 kV UHVDC transmission project[J].Power System Technology,2008,32(22):8-12(in Chinese).
[8]
范建斌,廖蔚明,李庆峰,等.±800 kV直流输电线路带电作业方式的试验研究[J].电力建设,2009,30(7):7-12.Fan Jianbin,Liao Weiming,Li Qingfeng,et al.Experimental research on live-line operation for ±800 kV DC transmission line [J].Electric Power Construction,2009,30(7):7-12(in Chinese).
[9]
肖勇,樊灵孟.云广±800 kV特高压直流线路带电作业分析[J].高电压技术,2010,36(9):2206-2210.Xiao Yong,Fan Lingmeng.Analysis of live working on Yun-Guang ±800 kV DC transmission line[J].High Voltage Engineering,2010,36(9):2206-2210(in Chinese).
胡毅,刘凯,刘庭,等.带电作业技术研究与标准制定[J].高电压技术,2012,38(11):3015-3024.Hu Yi,Liu Kai,Liu Ting,et al.Live working technology research and standards formulation [J].High Voltage Engineering,2012,38(11):3015-3024(in Chinese).
[15]
胡毅.送变电带电作业技术[M].北京:中国电力出版社,2004.
[16]
胡毅,王力农,邹伟.送配电带电作业的现状与发展[J].电力设备,2003,4(2):35-39.Hu Yi.Wang Linong,Zou Wei.Present state and development of live-line working technology on transmission and distribution lines[J].Electrical Equipment,2003,4(2):35-39(in Chinese).
[17]
丁一正.带电作业技术基础[M].北京:中国电力出版社.1998.
[18]
孙昭英,丁玉剑,廖蔚明,等.青藏直流联网工程空气间隙的海拔校正[J].电网技术,2010,34(5):8-12.Sun Zhaoying,Ding Yujian,Liao Weiming,et al.Altitude correction of air gaps of the Qinghai-Tibet DC interconnection project[J].Power System Technology,2010,34(5):8-12(in Chinese).
[19]
张小力,郝阳.青海—西藏±400 kV直流线路工程绝缘配合研究[J].电网与清洁能源,2012,28(6):39-43.Zhang Xiaoli,Hao Yang.Research on insulation coordination for ±400 kV Qinghai-Tibet HVDC transmission line [J].Power System and Clean Energy,2012,28(6):39-43(in Chinese).
[20]
GB/T 16927.1—2011高电压试验技术第一部分:一般试验要求[S].
[21]
胡毅,肖宾,刘凯,等.±500 kV同塔双回直流线路带电作业试验研究[J].高电压技术,2010,36(2):318-321.Hu Yi,Xiao Bin,Liu Kai,et al.Experimental research of live working on ±500 kV double circuit DC transmission line on the same tower [J].High Voltage Engineering,2010,36(2):318-321(in Chinese).