[1] | DU Y,ZAHN M,LESIEUTRE B C,et al. Moisture equilibrium in transformer paper-oil systems[J]. Electrical Insulation Magazine,1999,15(1):11-20.
|
[2] | OOMMEN T V. Moisture equilibrium charts for transformer insulation drying practice[J]. IEEE Trans. on Power Appar. Syst.,1984,103(10):3063-3067.
|
[3] | OOMMEN T V. Moisture equilibrium in paper-oil systems[C]//Proceedings of the Electrical/ Electronics Insulation Conference.Chicago:[s.n.],1983:162-166.
|
[4] | MORIN II A J,ZAHN M,MELCHER R J. Fluid electrification measurements of transformer pressboard/oil insulation in a couette charger[J]. IEEE Transactions on Electrical Insulation,1991,26(5):870-901.
|
[5] | KOCH M. Reliable moisture determination in power transformers[D]. Germany:University of Stuttgart,2008.
|
[6] | GRIFFIN P J. Water in transformers-so what![C]//National Grid Condition Monitoring Conference.Doble Engineering Company:[s.n.], 1996:1-16.
|
[7] | THOMAS Z M. Dielectrometry measurements of moisture diffusion and temperature dynamics in oil impregnated paper insulated electric power cables[D]. USA:Massachusetts Institute of Technology,2007.
|
[8] | MAMISHEV A V. Evaluation of diffusion-driven material property profiles using three-wavelength interdigital sensor[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2001,8(5):785-798.
|
[9] | DU Y,MAMISHEV A V,LESIEUTRE B C,et al. Moisture solubility for differently conditioned transformer oils[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2001,8(5):805-811.
|
[10] | 彭华东,董 明,刘 媛,等. 回复电压法用于变压器油纸绝缘老化状态评估[J]. 电网与清洁能源,2012,28(9):6-12. PENG Huadong,DONG Ming,LIU Yuan,et al. Transformer oil-paper insulation ageing condition assessment using return voltage measurements[J]. Power System and Clean Energy,2012,28(9):6-12.
|
[11] | 李 剑,陈晓陵,张召涛,等. 植物油纸绝缘的微水扩散特性[J]. 高电压技术,2010,36(6):1379-1384. LI Jian,CHEN Xiaoling,ZHANG Zhaotao,et al. Characteristics of moisture diffusion in vegetable oil-paper insulation[J]. High Voltage Engineering,2010,36(6):1379-1384.
|
[12] | SAHA T K,PURKAIT P. Understanding the impacts of moisture and thermal ageing on transformer’s insulation by dielectric response and molecular weight measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(2):568-582.
|
[13] | 周利军,汤 浩,吴广宁,等. 油纸绝缘微水扩散的稳态份布[J]. 高电压技术,2007,33(8):27-30. ZHOU Lijun,TANG Hao,WU Guangning,et al. Equilibrium moisture distribution in oil-paper insulation[J]. High Voltage Engineering,2007,33(8):27-30.
|
[14] | ZHOU L J,WU G N,LIU J. Modeling of transient moisture equilibrium in oil-paper insulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(3):872-878.
|
[15] | HILL D T,LE T T,DARVENIZA M,et al. A study of degradation of cellulosic insulation materials in a power transformer.part 1:Molecular weight study of cellulose insulation paper[J]. Polymer Degradation and Stability,1995(48):79-81.
|
[16] | UKSONG K,KENSALL D W. A high speed capacitive humidity sensor with on chip thermal reset[J]. IEEE Trans.Electr Devices,2000,47(4):702-710.
|
[17] | GARC??A D F,GARC??A B,BURGOS J C. Experimental determination of the diffusion coefficient of water in transformer solid insulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2012,19(2):427-433.
|
[18] | HILL D J T,LE T T,DARVENIZA M,et al. A study of degradation of cellulosic insulation materials in a power transformer.Part 2:Tensile strength of cellulose insulation paper[J]. Polymer Degradation and Stability,1995(49):429-435.
|
[19] | HILL D J T,LE T T,DARVENIZA M,et al. A study of the degradation of cellulosic insulation materials in a power transformer.Part III:Degradation products of cellulose insulation paper[J]. Polymer Degradation and Stability,1995(51):211-218.
|
[20] | GUIDI W W,FULLERTON H P. Mathematical methods for prediction of moisture take-up and removal in large power transformers[C]//IEEE Power Eng. Soc. (PES) Winter Power Meeting.[S.l.]:IEEE,1974:242-244.
|
[21] | FOSS S D. Power transformer drying model[C]//Report prepared for General Electric Company, Large Transformer Operation, Pittsfield, MA, and Consolidated Edison Corp..New York,USA:Dynamic Systems,Pittsfield,MA,1987:1-4.
|