全部 标题 作者
关键词 摘要

OALib Journal期刊
ISSN: 2333-9721
费用:99美元

查看量下载量

相关文章

更多...
高压电器  2014 

典型油纸绝缘微水扩散特性仿真分析及试验研究

, PP. 31-36

Keywords: 油纸绝缘,微水分布,菲克第二定律,绝缘纸老化,有限元分析,遗传算法

Full-Text   Cite this paper   Add to My Lib

Abstract:

绝缘纸受潮将严重影响变压器的内绝缘特性,变压器油纸绝缘体系中微水含量及微水分布状况是评估变压器绝缘状态的重要依据。基于菲克第二定律建立了油纸绝缘微水扩散的3种典型模型,并采用分离变量法和有限元方法对模型进行了仿真模拟。模拟了有化学反应参与的微水扩散过程,更符合绝缘纸长时间老化的微水扩散过程。搭建了微水随绝缘纸厚度梯度分布时测试实验平台,采用微水测试传感器测量微水含量。结合实验测量数据和微水扩散的有限元模型以及广泛采用的微水扩散系数经验公式,采用遗传算法寻优,获得了优化的微水扩散分布曲面。

References

[1]  DU Y,ZAHN M,LESIEUTRE B C,et al. Moisture equilibrium in transformer paper-oil systems[J]. Electrical Insulation Magazine,1999,15(1):11-20.
[2]  OOMMEN T V. Moisture equilibrium charts for transformer insulation drying practice[J]. IEEE Trans. on Power Appar. Syst.,1984,103(10):3063-3067.
[3]  OOMMEN T V. Moisture equilibrium in paper-oil systems[C]//Proceedings of the Electrical/ Electronics Insulation Conference.Chicago:[s.n.],1983:162-166.
[4]  MORIN II A J,ZAHN M,MELCHER R J. Fluid electrification measurements of transformer pressboard/oil insulation in a couette charger[J]. IEEE Transactions on Electrical Insulation,1991,26(5):870-901.
[5]  KOCH M. Reliable moisture determination in power transformers[D]. Germany:University of Stuttgart,2008.
[6]  GRIFFIN P J. Water in transformers-so what![C]//National Grid Condition Monitoring Conference.Doble Engineering Company:[s.n.], 1996:1-16.
[7]  THOMAS Z M. Dielectrometry measurements of moisture diffusion and temperature dynamics in oil impregnated paper insulated electric power cables[D]. USA:Massachusetts Institute of Technology,2007.
[8]  MAMISHEV A V. Evaluation of diffusion-driven material property profiles using three-wavelength interdigital sensor[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2001,8(5):785-798.
[9]  DU Y,MAMISHEV A V,LESIEUTRE B C,et al. Moisture solubility for differently conditioned transformer oils[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2001,8(5):805-811.
[10]  彭华东,董 明,刘 媛,等. 回复电压法用于变压器油纸绝缘老化状态评估[J]. 电网与清洁能源,2012,28(9):6-12. PENG Huadong,DONG Ming,LIU Yuan,et al. Transformer oil-paper insulation ageing condition assessment using return voltage measurements[J]. Power System and Clean Energy,2012,28(9):6-12.
[11]  李 剑,陈晓陵,张召涛,等. 植物油纸绝缘的微水扩散特性[J]. 高电压技术,2010,36(6):1379-1384. LI Jian,CHEN Xiaoling,ZHANG Zhaotao,et al. Characteristics of moisture diffusion in vegetable oil-paper insulation[J]. High Voltage Engineering,2010,36(6):1379-1384.
[12]  SAHA T K,PURKAIT P. Understanding the impacts of moisture and thermal ageing on transformer’s insulation by dielectric response and molecular weight measurements[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(2):568-582.
[13]  周利军,汤 浩,吴广宁,等. 油纸绝缘微水扩散的稳态份布[J]. 高电压技术,2007,33(8):27-30. ZHOU Lijun,TANG Hao,WU Guangning,et al. Equilibrium moisture distribution in oil-paper insulation[J]. High Voltage Engineering,2007,33(8):27-30.
[14]  ZHOU L J,WU G N,LIU J. Modeling of transient moisture equilibrium in oil-paper insulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2008,15(3):872-878.
[15]  HILL D T,LE T T,DARVENIZA M,et al. A study of degradation of cellulosic insulation materials in a power transformer.part 1:Molecular weight study of cellulose insulation paper[J]. Polymer Degradation and Stability,1995(48):79-81.
[16]  UKSONG K,KENSALL D W. A high speed capacitive humidity sensor with on chip thermal reset[J]. IEEE Trans.Electr Devices,2000,47(4):702-710.
[17]  GARC??A D F,GARC??A B,BURGOS J C. Experimental determination of the diffusion coefficient of water in transformer solid insulation[J]. IEEE Transactions on Dielectrics and Electrical Insulation,2012,19(2):427-433.
[18]  HILL D J T,LE T T,DARVENIZA M,et al. A study of degradation of cellulosic insulation materials in a power transformer.Part 2:Tensile strength of cellulose insulation paper[J]. Polymer Degradation and Stability,1995(49):429-435.
[19]  HILL D J T,LE T T,DARVENIZA M,et al. A study of the degradation of cellulosic insulation materials in a power transformer.Part III:Degradation products of cellulose insulation paper[J]. Polymer Degradation and Stability,1995(51):211-218.
[20]  GUIDI W W,FULLERTON H P. Mathematical methods for prediction of moisture take-up and removal in large power transformers[C]//IEEE Power Eng. Soc. (PES) Winter Power Meeting.[S.l.]:IEEE,1974:242-244.
[21]  FOSS S D. Power transformer drying model[C]//Report prepared for General Electric Company, Large Transformer Operation, Pittsfield, MA, and Consolidated Edison Corp..New York,USA:Dynamic Systems,Pittsfield,MA,1987:1-4.